General Safety Instructions| ArchiTech Pro DMX Control
EN Safety instruc ons
Electrical equipment may only be installed by a qualifi ed electrician. Failure to observe the instruc ons may cause damage to
the device and result in fi re and other hazards. Danger of electric shock. Device is not suitable for disconnec on from supply
voltage. Danger of electric shock. Always disconnect before carrying out work on the devise or load. At the same me, take
into account all circuit breakers that supply dangerous voltage to the device or load. These instruc ons are an integral part of
the product, and must remain with the end customer.
FR Consignes de sécurité
ES Instrucciones de seguridad
ATTENTION! Pour l’installa on électrique des luminaires, suivre les instruc ons fournies avec l’appareil. Les instruc ons
pour l’installa on d’autres accessoires disponibles peuvent être téléchargées à par r de notre site Web www.evaop c.
com (Documenta on).
NOTA: Para la instalación eléctrica de los focos, por favor, siga las instrucciones que vienen con el foco subacuá co. Las
instrucciones para la instalación de otros accesorios disponibles se pueden descargar desde nuestro si o web www.
evaop c.com (Documenta on).
NB! Voor de elektrische installa e van de lampen, volg de instruc es welke bij de onderwaterlamp zijn meegeleverd. Deze
instruc es en instruc es voor de installa e van andere beschikbare accessoires kunnen worden gedownload op onze
website www.evaop c.nl (Documenta e).
HINWEIS! Für die elektrische Installa on der Leuchten befolgen Sie bi e die mit der Unterwasserleuchte mitgelieferten
Anweisungen. Anleitungen für die Installa on von anderen erhältlichen Accessoires können von unserer Website www.
evaop c.com (Documenta on).
NOTA! Per l’installazione ele rico dei fare , si prega di seguire le istruzioni fornite con la lampada subacquea. Le istruzi-
oni per l’installazione di altri accessori disponibili possono essere scarica dal nostro sito web www.evaop c.com (Docu-
menta on).
NOTE! For the electrical installa on of the lights, please follow the instruc ons supplied with the underwater light.
Instruc ons for the installa on of other available accessories can be downloaded from our website www.evaop c.com
(Documenta on).
FR
ES
NL
DE
IT

Electrical Installation Instructions| ArchiTech Pro DMX Control
Step 1: Mount an electrical box inside the wall
Step 2: Prepare DMX cable Step 3: Connect Power supply controller
Step 4: Connect DMX cable to controller Step 5: Connect DMX cable to driver
Wiring overview
Not used
Step 6: Mount the interface on the wall

NTC
ADDRESS
2561286432168421 M
S
Status
Data-bus
terminator
LED Driver
EVA
D
E
Slave
Master
NTC
ADDRESS
2561286432168421 M
S
Status
Data-bus
terminator
LED Driver
EVA
D
E
Slave
Master
Wiring Diagram| ArchiTech Pro DMX Control
First & Next Drivers
Last Driver
Do not
connect
DMX shield
to ground!
Important:
For addressing the lights use binary DMX count or use a DIP switch calculator
Use EVA
Op c
datacable
(green)
EVA-AA-96
!
Do not
connect
DMX shield
to ground!
Use EVA
Op c
datacable
(green)
EVA-AA-96
!

Programming & Settings | ArchiTech Pro DMX Control
Non usato
PORTS Triggering
EN
FR
ES
DE
NL
IT

Confi guration ArchiTech Pro Control
EN
FR
ES
NL
DE
IT
Programming & Settings | ArchiTech Pro DMX Control

The EVA Op c DMX ArchiTech Pro Control is pre-confi gured with 9 preset scenes
Operating ArchiTech Pro Control
Program you own custom scenes with the so ware: h p://dmx.evaop c.nl
1. White Blanc Blanco Weiß Wit Bianco
2. Sky Blue - White/Blue Blanc/Bleu Blanco/Azul Weiß/Blau Wit/Blauw Bianco/Blu
3. Blue Bleu Azul Blau Blauw Blu
4. Mediterranean Bleu/Vert Azul/Verde Blau/Grün Blauw/Groen Blu/Verde
5. Green Vert Verde Grün Groen Verde
6. Red Rouge Rojo Rot Rood Rosso
7. Purple Violet Violeta Viole Paars Viola
8. Color change - Fade Changement couleur fade Cambio color fade Farbwechsel fade Kleurwissel fade Colore cambio fade
9. Color change - Jump Changement couleur jump Cambio color jump Farbwechsel jump Kleurwissel jump Colore cambio jump
User Manual | ArchiTech Pro DMX Control

Mobile apps Cer fi ca ons
So ware Dimensions
Power Working temperature
Technical specifi ca ons
Programming so ware & user manual downloadable
on h p://dmx.evaop c.nl
Logiciel de programma on et mode d’emploi téléchargeables sur h p://dmx.
evaop c.nl | El so ware para la programación y el manual del usuario se pueden
descargar en h p://dmx.evaop c.nl | Programmeerso ware en handleiding
downloaden op h p://dmx.evaop c.nl | Programmier-So ware & Bedienung-
sanleitung zum Download auf h p://dmx.evaop c.nl | So ware di program-
mazione e manuale d’uso scaricabili da h p://dmx.evaop c.nl
9V
Technical Specifi cations | ArchiTech Pro DMX Control
Table of contents
Other EVA Controllers manuals
Popular Controllers manuals by other brands

GE
GE IC3645SH7R354D1 Installation and operation manual

Mitsubishi Electric
Mitsubishi Electric MDS-EX-CVP Series Technical Specification and Instruction Manual

Carel
Carel ADE 10 Series quick start guide

SynScan
SynScan V2 instruction manual

Grundfos
Grundfos CU 3x4 Installation and operating instructions

Nexen
Nexen Paper Checker PC210 User manua