www.event-lighting.com.au
Product Operation
1. Connect the DMXRTWALL to a DMXRT using a CAT cable. The maximum
recommended cable length is 25m.
2. DMXRTWALL’s behaviour differs based on whether the jumper is installed. There are
two options:
a. With the jumper installed: Set DMXRT’s Trigger Event – Mode setting to
TOGGLE_TR. Pressing a button on DMXRTWALL will start the selected
program. Pressing the button again will immediately end the program.
b. Without the jumper installed: Set DMXRT’s Trigger Event – Mode setting to
NO_TR. Pressing a button on DMXRTWALL will start the selected program.
Pressing the button again will end the program once the currently active scene
reaches its end.
For more information, refer to the user manual for DMXRT.
3. Press the trigger buttons TR1 – TR6 on DMXRTWALL to activate/deactivate the
corresponding programs. When a program is active, the button will light up.
RJ45 Connector Pinout
• Pin 1 = Trigger 1
• Pin 2 = Trigger 3
• Pin 3 = Trigger 4
• Pin 4 = +12V
• Pin 5 = Trigger 6
• Pin 6 = Trigger 5
• Pin 7 = Trigger 2
• Pin 8 = GND
Trigger Connection
Each of the six modes (NO_TR, NC_TR, NCBK_TR, NOBK_TR, TOGGLE_TR and AUTO_TR)
can be used independently for separate triggers.
Technical Specifications
• Connection: Trigger connector RJ45
• Trigger buttons: 6
• Housing: Aluminium
• IP Rating: IP20
• Dimensions: 85*85*36mm
• Installation depth: 29mm
• Weight: 0.1kg