Evopower SF1000 User manual

Inverter Generator
Owner’s Manual Guide
D’Utilisation
Manual del Propietario
SF1000
SF2200
For product inquires or support, please visit www.evopower.co.uk or call our
registered offices support number on 01646 66 38 48.
Pour obtenir des renseignements sur les produits ou pour du soutien technique,
visitez notre site à l’adresse www.evopower.co.uk (en anglais seulement) ou
composez notre numéro sans frais 01646 66 38 48
Si tiene preguntas acerca de los productos o requiere de asistencia, visite
www.evopower.co.uk o llame gratis al 01646 66 38 48.

Congratulations on owning a Evopower inverter generator!
WARNING
This manual contains important instructions for operating this generator. For your safety, and the
safety of others, be sure to read this manual thoroughly before operating the generator. Failure to
properly follow all instructions and precautions can cause you and others to be seriously hurt or
killed.
Please use the spaces provided below to record important information about your generator. You may be asked to
provide this information should you require product service or support.
Identification information specific to your generator (model number and serial number) can be found on the genera-
tor nameplate.
p/n 101627 A
245453
Model Number: SF2200 Phas e: 1
Part Number: 101440A Frequency: 60Hz
AC/DC Voltage: 120V/12V Engine RPM: 5000
Power Output: 2.0kW Fuel: Gasoline
Max. Ambient Temp.: 40oC Insulation Class: F
Serial Number:
Date of Purchase:
Store/Dealer Purchased From:
Generator Model Number:
Generator Serial Number:
Genpower Ltd, Unit 1, Dowty Park
Milford Haven, Pembrokeshire,
United Kingdom SA73 2RS
TEL
01646 663848
www.evopower.co.uk
© 2009 Genpower Ltd
The Evopower Trademark is used
under
license
from
Genpower Ltd. Genpower Ltd makes no representations or
warranties with respect to this product.

PRODUCT REGISTRATION
To register your product, please complete the information below and mail to the address at the end of the form or register
online at www.Evopowergenerators.com. 18-digit serial number must be completed in order for warranty to be acti-
vated.
1 - PERSONAL INFORMATION
FIRST NAME
LAST NAME
PHONE
EMAIL
STREET ADDRESS
CITY, STATE, ZIP
COUNTRY
CHECK HERE TO RECEIVE ANNUAL MAINTENANCE REMINDERS AND SPECIAL OFFERS FROM EVOPOWER
GENERATORS
CHECK HERE TO RECEIVE INFORMATION FROM OTHER COMPANIES VIA EMAIL, UNDERSTANDING YOUR
EMAIL ADDRESS MAY BE SHARED OR COMBINED WITH INFORMATION FROM OTHER SOURCES
2 - PRODUCT INFORMATION
DATE OF PURCHASE:
/ /
MM DD YYYY
*MODEL NUMBER:
*SERIAL NUMBER (18-digits):
*Found on nameplate of generator
PURCHASE LOCATION:
IN-STORE
ONLINE
STORE NAME:
PURCHASE PRICE: $ .00
FEATURES INFLUENCING PRODUCT PURCHASE:
BRAND REPUTATION
EASE OF USE
PORTABILITY
SIZE / WEIGHT
POWER RATING
STYLE/APPEARANCE
PRICE WARRANTY
HOW DID YOU BECOME AWARE OF THIS PRODUCT?
IN-STORE
RADIO/TV
INTERNET STORE CIRCULAR
PRINT WORD OF MOUTH
OTHER BRANDS CONSIDERED WHEN SHOPPING
FOR THIS PRODUCT:
PRIMARY USE FOR PRODUCT:
TOOL POWER
RECREATION POWER
EMERGENCY POWER
PRIMARY LOCATION FOR PRODUCT USE:
HOME
WORK
TYPE OF WORK, IF PRODUCT BEING USED FOR
PROFESSION:
WHAT OTHER TYPE OF POWER EQUIPMENT ARE
YOU INTERESTED IN PURCHASING IN THE FUTURE?
WHO DECIDED TO PURCHASE THIS PRODUCT?

3 - DEMOGRAPHIC INFORMATION
GENDER:
MALE
FEMALE
MARITAL STATUS:
MARRIED
SINGLE
DATE OF BIRTH:
/ /
MM DD YYYY
INCLUDING YOURSELF, HOW MANY PEOPLE LIVE IN
YOUR HOUSEHOLD:
NUMBER OF CHILDREN UNDER 18 LIVING IN YOUR
HOUSEHOLD:
PRIMARY RESIDENCE:
OWN
RENT
EDUCATION:
SOME HIGH SCHOOL
HIGH SCHOOL DIPLOMA
COLLEGE DEGREE
GRADUATE DEGREE
HOUSEHOLD INCOME:
LESS THAN $15,000 $100,000 - $124,999
$15,000 - $29,999 $125,000 - $149,999
$30,000 - $49,999 $150,000 - $174,999
$50,000 - $79,999 $175,000 - $199,999
$80,000 - $99,999 $200,000 OR OVER
PRIMARY METHOD OF PURCHASING HOUSEHOLD
ITEMS:
IN-STORE
ONLINE
TV
MAIL ORDER
TYPES OF CREDIT CARDS HELD BY HOUSEHOLD
MEMBERS:
VISA / MASTERCARD
DISCOVER
AMERICAN EXPRESS
GAS / RETAIL
OTHER
NONE
HOUSEHOLD INTERESTS:
HOME IMPROVEMENT
AUTOMOTIVE WORK
CAMPING
OTHER
THANK YOU FOR REGISTERING YOUR PRODUCT. THE INFORMATION YOU PROVIDED MAY BE USED
FOR MARKETING PURPOSES IN ORDER TO OFFER YOU VARIOUS PRODUCT INFORMATION AND
OFFERS.
CHECK
HERE
IF YOU DO NOT
WISH
TO BE
CONTACTED
ABOUT
SPECIAL
OFFERS.
PLEASE RETURN THIS FORM TO THE FOLLOWING ADDRESS:
Genpower Ltd. (Evopower Manufacturer)
Unit 1, Dowty Park, Milford Haven, Pembrokeshire
United Kingdom, SA73 2RS
PLEASE MAIL THIS FORM IN A SEALED ENVELOPE. DO NOT STAPLE.

SF1000 / SF2200e Inverter Generator Owner’s Manual
www.evopower.co.uk
i
CONTENTS
IMPORTANT SAFETY RULES ............................................................................................ 1
Safety Messages
.........................................................................................................................................
1
Location of Important Labels
.......................................................................................................................
3
GETTING STARTED ......................................................................................................... 5
Package Checklist
.......................................................................................................................................
5
Record Generator Information
.....................................................................................................................
5
Grounding the Generator
.............................................................................................................................
6
Using Generator for Back-up Power
............................................................................................................
6
COMPONENTS ................................................................................................................. 7
Accessories
.................................................................................................................................................
7
Front and Back View
...................................................................................................................................
8
OPERATION ................................................................................................................... 11
Generator Location
....................................................................................................................................
11
Preparing for Operation
.............................................................................................................................
11
Starting Generator
.....................................................................................................................................
12
AC Operation
.............................................................................................................................................
14
Stopping Generator
...................................................................................................................................
14
Low Oil Protection
.....................................................................................................................................
14
High-Altitude Operation
.............................................................................................................................
14
Powering Appliances
.................................................................................................................................
15
Appliance Wattage Information
.................................................................................................................
15
MAINTENANCE .............................................................................................................. 17
Maintenance Schedule
..............................................................................................................................
17
Engine Oil
..................................................................................................................................................
18
Engine Fuel
...............................................................................................................................................
21
Cleaning Fuel Strainer
...............................................................................................................................
22
Air Filter Maintenance
................................................................................................................................
23
Cleaning Spark Arrestor Screen
................................................................................................................
24
Spark Plug Service
....................................................................................................................................
25
Transporting Generator
.............................................................................................................................
26
Storing Generator
......................................................................................................................................
26
TROUBLESHOOTING .................................................................................................... 27
SPECIFICATIONS AND WIRING DIAGRAMS ............................................................... 29
WARRANTIES ................................................................................................................ 33
NORTHSHORE POWER SYSTEMS CONSUMER LIMITED WARRANTY
.............................................
33
NORTHSHORE POWER SYSTEMS EMISSIONS CONTROL WARRANTY
...........................................
34
INDEX .............................................................................................................................. 37
MAINTENANCE PARTS ................................................................................................. 39

ii
www.evopower.co.uk
SF1000 / SF2200e Inverter Generator Owner’s Manual
THIS PAGE INTENTIONALLY LEFT BLANK

SF1000 / SF2200e Inverter Generator Owner’s Manual
www.evopower.co.uk
1
DANGER
Indicates an imminently hazardous situa-
tion which, if not avoided, will result in
death or serious injury to the operator or
to bystanders.
WARNING
Indicates a potentially hazardous situa-
tion which, if not avoided, could result in
death or serious injury to the operator or
to bystanders.
CAUTION
Indicates a potentially hazardous situa-
tion which, if not avoided, may result in
moderate or minor injury to the operator
or to bystanders.
NOTICE
Indicates a situation which, if not avoided,
may result in damage to the generator
components.
SAVE THESE INSTRUCTIONS
IMPORTANT SAFETY RULES
WARNING
ANYONE using or servicing this generator must read, understand, and follow all safety and operation instructions pro
-
vided in the product manual. Failure to closely follow these instructions can result in circumstances leading to death,
serious injury, and property damage.
NOTE:
Since there are many variations in the circumstances sur-
rounding the installation, operation, service, and mainte-
nance of this generator, we cannot possibly anticipate or
provide advice or safety messages to cover every situa-
tion.
Hazard Symbols and Meanings
In addition to the signal words, the following symbols may
be used to draw your attention to specific types of haz-
ards.
Signal Words
Safety messages are provided throughout this manual to
help prevent personal injury and equipment damage. All
safety messages are introduced by a signal word indicat-
Explosion Toxic fumes Fire
ing the
hazard
level.
Chemical burn
Electrical shock
Hot surface
DANGER
Using a generator indoors CAN KILL YOU IN MINUTES.
Generator exhaust contains carbon monoxide. This is a poi-
son you cannot see or smell.
Only use OUTSIDE and far
away from windows, doors, a
nd
vents.
NEVER use inside a home
or garage, EVEN IF doors
and windows are open.

www.evopower.co.uk
2
SF1000 / SF2200e Inverter Generator Owner’s Manual
WARNING
Generators produce powerful voltage that can cause
death or great physical harm.
•
NEVER touch bare wires or receptacles.
•NEVER use generator with electrical cords that are
worn, frayed, bare, or otherwise damaged.
•NEVER operate generator in rain or snow, or when
the generator is set on wet surface.
•Keep the generator out of reach of children, pets,
and untrained people.
Safety Messages
Safety Messages
Electric Shock Hazards
Fire and Burn Hazards
WARNING
Medical and Life Support Uses
WARNING
•In case of emergency, call 911 immediately.
•NEVER use this product to power life support
devices or life support appliances.
•NEVER use this product to power medical devices
or medical appliances.
•Inform your electricity provider immediately if
you
or
anyone in your household depends on electric
al
equipment to live.
•Inform your electrical provider immediately if a loss
of power would cause you or anyone in your
household to experience a medical emergency.
Generator Damage Hazards
Fuel and its vapors are extremely flammable and
explosive under certain conditions.
•Refuel generator only outdoors, in a well-ventilated
area.
•NEVER enclose the generator in any structure.
•Keep generator at least 6 feet (2 meters) away from
buildings, other equipment, and combustible mate-
rials during operation.
•NEVER fill fuel tank while the engine is running.
Turn generator OFF and allow to cool before filling
with fuel.
•NEVER smoke or allow flames or sparks near the
generator or where gasoline is stored.
•NEVER overfill the fuel tank (there should be no
fuel in the filler neck). After refueling, make sure the
tank cap is closed properly and securely.
•Be careful not to spill fuel when refueling. Spilled
fuel or fuel vapor may ignite. If any fuel is spilled, be
sure the area is dry before starting the engine.
•Avoid repeated or prolonged contact with skin or
breathing of vapor.
NOTICE
Improper treatment or misuse of generator can cause per-
manent damage.
•NEVER modify generator in any way.
•NEVER tamper with governed speed. Generator sup-
plies correct rated frequency and
voltage
when
run-
ning at governed speed.
•Damage to generator caused by misuse or modifi-
cation is not covered under Warranty.
WARNING
The muffler becomes very hot during operation and
remains hot for a while after stopping the engine.
•NEVER touch hot surfaces and avoid hot gases.
•Let engine cool before storing the generator
indoors.

www.evopower.co.uk
SF1000 / SF2200e Inverter Generator Owner’s Manual
3
A
A
Location of Important Labels
Location of Important Labels
Location of Important Labels
Your generator has several labels which provide important safety and maintenance information. Samples of these labels are
provided below. Should any of these labels become illegible or damaged, call 01646 663848 for replacements.
A F
B
D
G
C H
FIGURE 1: SF1000 Model Label Locations
A
B
D
G
E
C F H
FIGURE 2: SF2200 Model Label Locations
PRODUCT LABEL
PART NUMBER
A
101589A
DANGER
Using a
generator
indoors CAN
KILL
YOU IN
MINUTES.
Generator
exhaust
contains
carbon
monoxide.
This is a
poison
you
cannot
see
or
smell.
NEVER use
inside
a
home
or
garage,
EVEN
IF
doors
and
windows
are
open
Only use
OUTSIDE
and
far
away
from
windows,
doors,
and
DANGER
L'utilisation
d’une
génératrice
à
l’intérieur
peut
CAUSER LA
MORT
EN
QUELQUES
MINUTES.
L’échappement de la
génératrice
dégage
du
monoxyde de
carbone.
Ce produit
ne
doit JAMAIS être
utilisé
à l’intérieur d’une maison
ou
d’un garage,
MÊME SI les
porte s et les
fenêtres
sont
Utilisez
SEULEMENT
à
l’extérieur
et tenez éloigné des
fenêtres,
portes
et
prises
d’air
ouvertes.
PELIGRO
Utilizar
un
generador
en el
interior
PUEDE M ATARLO
EN
CUESTION
DE
MINUTOS.
Los
gases
de
escape
del
generador
contienen
monóxido
de
carbono.
Estees
un
veneno
queno
se
ve,ni
huele.
NUNCA lo
utilice
dentro
del
hogar
ni
del
garaje
AUNQUE
estén
abiertas
las
puertas
y
las
ventanas.
Utilícelo
siempre
AFUERA
y
lejos
de
ventanas,
puertas
y
ventilas.
B
101591A

www.evopower.co.uk
4
SF1000 / SF2200e Inverter Generator Owner’s Manual
CAUTION
Air intake located on bottom
of inverter. DO NOT
BLOCK
ATTENTION
Entrée d’air sur le bas de l’inverseur.
MAINTENEZ LA ZONE CLAIRE.
CUIDADO
El aire entra en el fondo de
la unidad. NO BLOQUEE.
p/n: 101588A
E
2
2
3
1
10
3
4
5
10
9
1
4
5
6
Location of Important Labels
Location of Important Labels
C 101588A
D OFF
CHOKE
p/n 101605A
ON ON
CHOKE
p/n 101610A
OFF 101605A (SF1000 Model)
101610A (SF2200 Model)
p/n 101726A
TO START
PRIME ENGINE 3 TO 5X
INITIAL OR DRY START
PRIME ENGINE 30 TO 50X
101726A (SF2200 Model)
101590A (SF1000 Model)
F 101628A (SF2200 Model)
SMART START INSTRUCTIONS
SF1000
ALL USERS MUST READAND UNDE RSTAND OW NER’S MANUAL!
TOUS LES UTILIS ATEURS DOIVENT LIRE ET CO MPREND RE LE GUIDE D'UTILISATION!
TODOS LOS USUARIO S DEBEN LEER Y COMPRENDE R EL MANUAL OPERACIÓN!
CHECK OIL & FUE L LEVEL.
VÉRIFIE Z LE NIVE AU D'HUILE ET DE
CARBURA NT
.
REVISE LOS NIVELES DE ACEI TE Y
COMBUSTIBLE.
SMART START INSTRUCTIONS
SF2200
ALL USE RS M UST REA D AND U NDE RS TANDOWNER’S MANUAL!
TOUS LES UTILIS ATEURS DOIVENT LIRE ET CO MPREND RE LE GUIDE D'UTILISATION!
TODOS LOS USUARIO S DEBEN LEER Y COMPRENDE R EL MANUAL OPERACIÓN!
CHECK OIL & FUE LLEVEL.
VÉRIFIE Z LE NIVE AU D'H UILE ET DE
CARBURA NT
.
REVISE LOS NIVELES DE ACEI TE Y
MOVE INVE RTE R OUTSIDE.
DÉPLACEZ L'ONDU LATEUR À
L’EXTÉRIEU R.
MUEVA EL INVERSOR HAC IA
AFUERA.
G
PL UG IN PO WER
CORDS
.
BRANCHE Z LES
CORDONS
D’ALIMENTA TIO N.
MOVE CHOKE TO ON.
ME TTE Z L’ÉTRANGLEUREN P OSITIO N ON.
MUEVA EL CONTROL DE
AHOGO A ENCENDI DO
.
TURN F UEL VENT ON.
OUVREZ LA M ISE À L’AIR
LIBRE CA RBURAN T
.
MUEVA EL RESPIRA DERO
DE COMBUSTIBLE A
ENCENDI DO
.
TURN F UEL VALVE ON.
OUVREZ LE R OBINET
DE CARBURA NT
.
MUEVA LA VÁLVULA
DE COMBUS TIBLE
A ENCENDIDO
.
M OVE ENGINE S WI TCH TO RUN
AND EFFICIENCY M ODE TO OFF
.
ME TTE Z LE COMMUTATE UR DU
MOVE INV ERTER O UTSIDE.
DÉPLACEZ L'ONDU LATEUR À
L’EXTÉRIEU R.
MUEVA EL INVERSOR HAC IA
AFUERA.
P LUG IN POW E R
CORDS
.
BRANCHE Z LES
CORDONS
D’ALIMENTA TIO N.
CONECTE LO S
CABLES
.
CHECK READY LIG HT ON.
ASSUREZ-VOUS QUE LE V OYANT
LUMINEU X EST ALLUMÉ.
ESPÉRESE HA STA QUE SE
COMBUSTIBLE. MOVE CHOKE TO O N.
ME TTE Z L’ÉTRANGLEUREN P OSITIO N ON.
MUEVA EL CONTROL DE AHOGO A
ENCENDI DO
.
TURN F UEL VALVE ON.
OUVREZ LE R OBINET
DE CARBURA NT
.
MUEVA LA VÁLVULA
DE COMBUS TIBLE
A ENCENDIDO
.
PRIME E NGINE 3X.
INJEC TEZ DU
CARBURA NT 3 X.
EMPUJE EL BULBO
TRES VE CES
.
6
MOVE ENGINE S W ITCH
101596A* (SF1000 Model)
101597A* (SF2200 Model)
CONECTE LOS CABLES
.
MOTE UR EN P OSITION RUN ET
LE MODE D'EFFICACITÉ EN ENCIENDA LA LUZ L ISTA. TO RUN AND EFFICIENCY
MODE TO OFF
.
IF TA NK LOW OR RUN TO
EMPTY, PR IME30 TO 50 X.
ME TTE Z LE COMMUTATE UR SI LE RÉSERVOIR EST
BAS
9
CHECK REA DY LIGHT O N.
7
PULL RECOIL TO S TA RT
.
POSITION
OFF
.
8
MOVE CHOK E TO OFF
.
7
PULL RECOIL TO S TART
.
DU M OTEU R EN
POS ITION OU SE VIDE, INJECTEZ DU
ASSUREZ-VOUS QUE LE V OYANT
LUMINEU X EST ALLUMÉ. TIREZ LE LA NCEUR À
RAPPELP OUR
MUEVA EL CONTROL DE M OTOR
A EJECU TARY EL MODO DE M ETTE Z L’ÉTRANGLEU R
EN POSITIO N OFF
.
TIRE Z LE LANCE UR À RUN ET LE MODED'EFFICA -CARBURA NT 30 À 50 X.
SI EL TANQUE BAJOO EL
ESPÉRESE H AS TA QUESE
8
M OVE CHOKE TO
OFF
.
DÉMARRE R. EFICACIA A A PAGADO
.
RAPPEL POUR DÉMARRE R. CITÉ EN POSITIO N OFF
.
ENCIENDA LA LUZ LISTA. METTE Z L’ÉTRANGLEU R
EN POSITIO N OFF
.
JALE LA CUERDA DE
MUEVA EL CONTROL DE
AHOGO A APAGADO
.
JALE LA CUERDA DE
REBOBINADO PA RA
MUEVA EL CONTROL DE
MOTOR A EJECUTARY EL
FUNCIONA MIENTO A
VACÍO
,
EMPUJE EL BULBO
MUEVA EL CONTROL DE REBOBINADOPARA ARRA NCAR. MODO DE E FICACIA A 30 - 50 VE CES
.
AHOGO A APAGADO
.
ARRANCAR. APAGADO
.
STOPPI NG INSTRUCTIONS INSTRUCTIONS D’ARRÊT INSTRUC TIONS PARA
DETENER STOPPING INSTRUCTIONS INSTRUC TIO NS D’ARRÊT INS TRUCTI ONS PARA DETENER
1
UNPLUG POW ER CORDS
.
2
MOVE ENGINE S WITC H TO STOP
.
3
TU RN F UEL VALVE
OFF
.
4
TURN F UEL VENT
OFF
.
UNPLUG P OWER CORDS
.
MOVE ENGI NE SW ITCH TO S TOP
.
TURN FUELVALVE OFF
.
DÉBRA NCHEZ LES CO RDONS ME TTEZ LE COMMUTATE UR
DU FERMEZ LE ROBINET DE
CARBURA NT
.
FERMEZLA M ISE À L’A IR
1
DÉBRA NCHEZ LE S
CORDONS
2
MET TE Z LE COMMUTA TEU R
DU
3
FERMEZ LA MIS E À L’ AIR
D’ALIMENTA TIO N. MO TEUR EN P OSITION D’A RRÊT
.
M UEVA EL RESPIRADE RO DE LIBR E CARBURAN T
.
D’ALIMENTA TIO N. MO TEUR EN P OSITION D’A RRÊT
.
LIB RE CARBU RANT
.
DESENC HUFE LOS CABLES
.
MUEVA EL CONTROL DE MOTOR A COMBUSTIBLE A
EJECUTAR. DETENER.
MUEVA LA VÁLVULA
DE COMBUS TIBLE
A APAGADO
.
DESENC HUFE LOS CABLES
.
MUEVA EL CONTROL DE M OTOR A
DETENER.
MUEVA LA VÁLVULA DE
COMBUSTIBLEA A PAGADO
.
FOR
24-HOUR STARTING
INSTRUC TIONS
1-888-RECOIL-8
(732-
6458)
p/n 101596A
FOR
24-HOUR
STARTING INSTRUCTIONS
1-888-RECOIL-8
(732-6458)
p/n 101597A
OFF
H FUEL 101592A
ON
p/n 101592A
TABLE 1. Safety Labels
WARNING
* The Smart Start instruction label is NOT intended to replace information provided in this Owner’s Manual.
Be sure to
thoroughly read and understand all information provided in the Owner’s Manual before operating the generator. Fail
ure
to properly follow all instructions and precautions can cause you and others to be seriously injured or killed.

SF1000 / SF2200e Inverter Generator Owner’s Manual
www.evopower.co.uk
5
GETTING STARTED
Use the information in this section to get your generator ready for operation.
WARNING
ANYONE using this generator must read, understand, and follow all safety and operation instructions provided in the
product manual. Failure to closely follow these instructions can result in circumstances leading to death, serious
injury, and property damage.
Package Checklist
CAUTION
Generator is heavy! Obtain assistance to lift the generator to avoid back or other bodily injury.
Verify that all of the following items are included in the generator package:
Inverter Generator
Owner’s Manual
Oil Fill Container
Oil Drain Pipe
Spark Plug Wrench
Screwdriver Handle
Screwdriver Universal Bit
Inspect for Damage
Carefully inspect generator for any damage that may have occurred during shipment. If loss or damage is noted after
opening, separate damaged materials and call 01646 663848.
Record Generator Information
Write down the identification information specific to your generator in the spaces provided on the inside cover of this
Owner’s Manual. This information is located on the generator nameplate (see illustration below).
Northshore Power Systems, LLC
Milwaukee, WI 53212 USA
p/n 101627A
245453
Model Number: SF2200 Phase: 1
Part Number: 101440A Frequency: 60Hz
AC/DC Voltage: 120V/12V Engine RPM: 5000
Power Output: 2.0kW Fuel: Gasoline
Max. Ambient Temp.: 40oC Insulation Class: F
Serial Number:
FIGURE 3: Generator Nameplate Location

www.evopower.co.uk
6
SF1000 / SF2200e Inverter Generator Owner’s Manual
Grounding the Generator
Grounding the Generator
Grounding the Generator
WARNING
Generator must be grounded to prevent electrical
shock from faulty appliances.
• Before using generator, consult a qualified electrician,
electrical inspector, or local agency having jurisdiction
for local codes or ordinances that apply to the intended
use of generator.
The National Electric Code requires the generator to
be
connected to an earth ground. Before using the generator,
connect a copper wire (minimum 14 AWG) from the
ground terminal (see Figure 4) to an earth ground. Con-
sult a licensed electrician for proper grounding methods.
Using Generator for Back-up Power
DANGER
Before connecting to a building’s electrical system, consult
your local utility company or a qualified electrician.
Improper connections to a building's electrical system can
be deadly.
Electrical current from generator can feedback into
utility lines. Such feedback may electrocute utility
company workers or others who contact utility lines
during a power outage.
Electrical current can feedback into generator. When
utility power is restored, generator may explode,
burn, or cause fires in building's electrical system.
The National Electric Code requires any generator con-
nected to a building’s electrical wiring utilize a transfer
switch installed by a licensed electrician.
What is a transfer switch?
A transfer switch is a device that allows switching
from utility power to emergency generator power.
The transfer switch is either a manual switch, an
automatic switch, or a combination of manual and
automatic. During a power outage, the transfer
switch isolates emergency circuits from the utility
line, allowing for efficient operation of the generator
without back-feeding into utility power.
FIGURE 4: Ground Terminal (SF2200 model illustrated)
NOTE:
The system ground is not connected to the AC neutral
wire. If using a receptacle tester, it will not show the same
ground circuit condition as for a home receptacle.
Special Requirements
There may be Federal or State Occupational
Safety
and
Health Administration (OSHA) regulations, local codes, or
ordinances that apply to the intended use of generator.
Please consult a qualified electrician, electrical inspector,
or the local agency having jurisdiction.
•In some areas, generators are required to be regis-
tered with local utility companies.
•If generator is used at a construction site, there may
be additional regulations which must be observed.

SF1000 / SF2200e Inverter Generator Owner’s Manual
www.evopower.co.uk
7
COMPONENTS
Use information provided in this section to become familiar with your generator’s components.
CAUTION
The information below is provided for reference only. Refer to “OPERATION” on page 11 for instructions on
operating generator.
Generator is heavy! Obtain assistance to lift the generator to avoid back or other bodily injury.
Accessories
Oil Drain
Pipe
Oil Fill Container
Screwdriver Handle Screwdriver
Universal
Bit
Spark Plug Wrench
FIGURE 5: Inverter Accessories

www.evopower.co.uk
8
SF1000 / SF2200e Inverter Generator Owner’s Manual
CAUTION
Generator must be grounded to prevent electrical
shock from faulty appliances. See page 6.
Front and Back View
Front and Back View
Front and Back View
SF1000 Model
4
5
3
6
7
2 8
1
B
F
A C G
D J
A—Control Panel
E
H
3. Breakers
1. Outlets
125VAC outlet(s) (NEMA 5-15R [SF1000 model] and NEMA
5-20R [SF2200 model]) to connect 120V appliances to gen-
erator for power.
DC outlet ranges from 12 to 18 volts and is unregulated. This
outlet should not be used for battery charging.
Protect circuits from damage caused by
overload or short-circuit by stopping flow
of electricity from generator to the appli-
ance. If there is no power at outlets, see
“Troubleshooting” on page 27.
4. Overload Indicator Light
DC
AC
Set Tripped
WARNING
NEVER use unapproved DC cables as this can
result in circumstances leading to death, serious
injury, and property damage. ALWAYS use Honey-
well DC accessory cables (sold separately) available
from a Evopower dealer.
2. Ground Terminal
Connects generator to ground wire for grounding protection.
Illuminates red when the generator is overloaded or if there is
a short circuit in a connected appliance. Turn the generator
off immediately and determine the reason for the overload.
5. Output Indicator Light
Illuminates green when the generator is running under nor-
mal operating conditions.
6. Oil Alert Indicator Light
Illuminates red when low oil conditions are present and the
generator is running (or while recoil
is
pulled)
. The engine
will automatically stop to prevent generator damage.

www.evopower.co.uk
SF1000 / SF2200e Inverter Generator Owner’s Manual
9
WARNING
Muffler reaches temperatures that can cause serio
us
burns if touched. NEVER touch hot surfaces.
Front and Back View
Front and Back View
SF2200 Model
6
8
5
4
7
3
1
2
B
F
G
C
A
E J
D I
H
7. Engine Control Switch
Turns the engine ON or OFF.
8. Efficiency Mode Switch
When Efficiency Mode is ON, the engine speed will automati-
cally adjust based on the connected load, resulting in better
fuel consumption and less noise.
In DC operation, set the Efficiency Mode Switch to the
OFF position.
B—Top Maintenance Cover
Provides access to the engine spark plug.
C—Muffler
Provides outlet for engine exhaust.
D—Case Feet
Provides stability to the generator.
E—Recoil Starter Handle
Starts engine.
F—Back Maintenance Cover
Provides access to air filter, fuel filter, and oil fill cap.
G—Fuel Cap
Provides a secure seal on fuel tank. The SF1000 model has
a vented fuel cap.
H—Fuel Valve
Controls flow of fuel from fuel tank to carburetor.
I— Primer Bulb (SF2200 model only)
Provides primer fuel to start engine.
J—Choke Control
Controls choke valve. Choke control must be in the ON posi-
tion when startingacold engine.

10
www.evopower.co.uk
SF1000 / SF2200e Inverter Generator Owner’s Manual
THIS PAGE INTENTIONALLY LEFT BLANK

SF1000 / SF2200e Inverter Generator Owner’s Manual
www.evopower.co.uk
11
OPERATION
Generator
Location
When deciding on the location to place your generator,
keep in mind the following safety rules:
DANGER
Depressed areas such as construction foundations,
pools, or any low-lying areas, can cause carbon
monoxide to accumulate. Inhalation of carbon mon-
oxide can kill you in minutes.
• NEVER use generator inside homes, garages,
crawl spaces, sheds, or similar enclosed
spaces. Use generator only outdoors and far
away from windows, doors, and vents.
WARNING
If generator is placed on an uneven or flexible sur-
face, generator could tilt or overturn, causing fuel to
spill from gas tank. Spilled fuel could ignite.
• Place generator on firm, level surface and avoid
loose sand or snow. If generator is tilted or
overturned, fuel spillage may result. Also, if
generator is overturned or sinks into a soft sur-
face, sand, dirt, or water may enter generator.
WARNING
NEVER operate generator in rain or snow, or
when the generator is set on wet surface.
WARNING
Keep generator at least 6 feet (2 meters) away
from buildings, other equipment, and combustible
materials during operation.
Preparing for Operation
DANGER
Using a generator indoors CAN KILL YOU IN MINUTES.
Generator exhaust contains carbon monoxide. This is a poi-
son you cannot see or smell.
Only use OUTSIDE and far
away from windows, doors, and
vents.
NEVER use inside a home
or garage, EVEN IF doors
and windows are open.
Before starting generator, complete the following prepara-
tion tasks:
Be sure generator is placed outdoors in a
well
ventilated area.
Check/add engine oil— IMPORTANT! BEFORE
STARTING GENERATOR, FILL WITH ENGINE OIL.
See page 18 -p. 21 for instructions on filling, check-
ing, and changing oil.
Check/add fuel—ADD FUEL. See page 22.
Check air filter—See “Air Filter Maintenance”
on
page 23.
Be sure ground terminal is properly connected
to
earth ground—See “Grounding the Generator” on
page 6.
Check extension cords—be sure cords are:
In good condition.
Rated for outdoor use and match amperage
and
voltage ratings of generator outlet.
Equipped with proper plugs that contain
grounding
blades.

www.evopower.co.uk
12
SF1000 / SF2200e Inverter Generator Owner’s Manual
Starting Generator
Starting Generator
Starting Generator
WARNING
Before starting generator, be sure to thoroughly read
all information provided in this Owner’s Manual.
NOTICE
It is very important to maintain the proper level of engine oil
to keep the engine in good running condition.
• Check engine oil level prior to each use.
IMPORTANT! BEFORE STARTING GENERATOR, FILL
WITH ENGINE OIL.
Starting generator with appliances connected can cause
permanent damage to appliances.
• NEVER start generator with electrical appliances
plugged in and turned on.
• Do not move the generator while it is running.
4. Move the choke to the ON position.
NOTE:
Place the choke in the OFF position when the SF1000
has a warm engine.
5. Set the efficiency mode switch to the
OFF
position.
FIGURE 7: Efficiency
Mode
Swi
t
ch
6. Turn the fuel valve to the ON position.
OFF
FUEL
1. Fill the fuel tank and check oil is to appropriate level.
NOTE:
The generator starts more easily with a full fuel tank.
2. Place the generator outside on a flat surface free of
debris to prevent blocking the air intake vents in the
bottom of the generator.
ON
p/n 1015 92A ON
FIGURE 8: Fuel Valve —
ON
position
7. Press the engine control switch to the RUN position.
FIGURE 9: Engine Control Switch
8. SF1000 Model Only: Turn the fuel cap vent to the
ON
position.
FIGURE 6: Air Intake - DO NOT BLOCK
NOTICE
Blocking the air flow may cause damage to the generator.
3. Connect a ground wire to the generator (see “Ground-
ing the Generator” on page 6).
FIGURE 10: Fuel Cap Vent — ON position

www.evopower.co.uk
SF1000 / SF2200e Inverter Generator Owner’s Manual
13
Starting Generator
Starting Generator
SF2200 Model Only: Depress the primer bulb 3
times to supply fuel to start the engine.
12. After starting, confirm the output ready indicator light
is green and stays on.
FIGURE 11: Prime Engine
NOTE:
INITIAL START: Depress the primer bulb 30-50 times to
prime the fuel lines.
NOTE:
If the generator has a low fuel tank or has been run to
empty before being refilled, the primer bulb may need to
be depressed 30-50 times to prime the fuel lines.
9. While securing the generator with one hand, grip the
recoil starter handle and pull slowly until you feel
slight resistance. (SF2200 model illustrated)
FIGURE 13: Output Ready Indicator Light (SF1000 model)
13. Allow the engine to run continuously and warm up
before connecting any appliance.
NOTICE
If the engine stops and will not restart, check the engine oil
level before troubleshooting in other areas.
FIGURE 12: Recoil Starter Handle
10. Apply 1 to 4 swift pulls to start the engine, carefully
returning the recoil starter handle to the original posi-
tion.
NOTICE
To prevent damage to the generator, do not allow the recoil
starter handle to snap back against the engine.
11. After the engine starts, let run for 2-5 seconds and
then slowly move the choke to the OFF position.

www.evopower.co.uk
14
SF1000 / SF2200e Inverter Generator Owner’s Manual
AC Operation
AC Operation
AC Operation
NOTE:
DC power and AC power can be used at the same time.
1. Turn off and unplug all equipment to be plugged into
the generator.
2. Start the generator (see “Starting Generator” on
page 12).
3. Plug in the appliance and monitor the overload indica-
tor light. If the overload indicator illuminates longer
than 4 seconds, STOP THE ENGINE IMMEDIATELY.
Do not restart generator until the reason for the over-
load or appliance short circuit is corrected.
Low Oil Protection
The oil alert system is designed to avoid engine damage
from not enough oil in the crankcase. The oil alert system
will stop the engine automatically before the crankcase oil
gets below the safety line.
The
engine
will not restart until
the required amount of engine oil is added.
NOTE:
Oil alert indicator light only illuminates while generator is
running or while recoil is pulled.
FIGURE 14: Overload Indicator Light (SF2200 model)
CAUTION
Substantial overloading that continuously lights the overload
indicator light may damage the generator. Marginal overload-
ing that temporarily lights the overload indicator light may
shorten the service life of the generator.
If appliance begins to operate abnormally, becomes slug-
gish, or stops suddenly, turn it OFF immediately. Disconnect
appliance and determine whether problem is appliance, or if
rated load capacity of generator has been exceeded.
4. Set the efficiency mode switch to the ON position.
FIGURE 15: Efficiency
Mode
Switch
Stopping Generator
In an emergency:
Press the engine control switch to the STOP position.
In normal use:
1. Turn OFF any connected appliances and unplug any
connected power cords.
2. Allow the generator to run for 2-3 minutes.
3. Press the engine control switch to the STOP position.
4. Turn the fuel valve to the OFF position.
5. Turn the fuel cap vent to the OFF position (SF1000
model only).
FIGURE 16: Oil Alert Indicator Light
High-Altitude
Operation
At high altitudes, standard carburetor air-fuel mixture will
be excessively rich. Performance will decrease and fuel
consumption will increase.
High-altitude performance can be improved by installing a
smaller diameter main fuel jet in the carburetor and then
readjusting the pilot screws. If you always operate the
engine at altitudes higher than 5000 feet (1500 meters)
above sea level, have an authorized generator dealer per-
form this carburetor modification.
Even with suitable carburetor jetting, engine horsepower
will decrease approximately 3.5% for each 1000 foot (300
meters) increase in altitude above sea level. The effect of
altitude on horsepower will be greater than this if no car-
buretor modification
is
made.
NOTICE
If engine jetted for high altitude is used at lower altitude, lean
air fuel mixture will reduce performance and may over-heat
and seriously damage the engine.
This manual suits for next models
1
Table of contents
Other Evopower Portable Generator manuals
Popular Portable Generator manuals by other brands

LIPOWER
LIPOWER PA300 user manual

Champion Global Power Equipment
Champion Global Power Equipment 201047 Operator's manual

Ryobi
Ryobi RG-3500 Owner's operating manual

Troy-Bilt
Troy-Bilt 30237 owner's manual

B+K precision
B+K precision 4013DDS instruction manual

FRONIUS