EVOVX EVOAQ User manual

EVOAQ Ventilation Controller
Please read all instructions before commencing installation.
Power ON/OFF
Ventilation rate adjust
Mode
Set Comfort Temperature Up
Set Comfort Temperature Down
INSTALLATION INSTRUCTIONS
Automated Touch Screen Overview
This digital controller has been specifically designed to ensure the best possible ventilation for
your home. The large screen is designed to measure the indoor air temperature using a high
precision built-in sensor.
The digital controller communicates your ventilation requirement to the intelligent fan control
board which is constantly sensing the air quality and adjusting the fan speed. By selecting the
ventilation requirement this control board will increase/decrease the amount of ventilation to
your house. The ventilation requirement is adjusted according to your Set Comfort
Temperature.
No further inputs or adjustments are required. Simply set and forget.
Display Information
Off System is Off. The system will switch to shutdown mode and stop after several minutes.
Set Comfort Temperature – The controller adjusts the ventilation requirement according to the
set temperature. Adjust the set temperature using the Adjust Up and Down buttons.
Mode Switch between Summer and Winter mode
Summer - Heat Transfer OFF / Air is taken from outside
Winter - Heat Transfer ON / Air is taken from the roof space
NB Without the respective air source options installed the mode selection has no effect.
Page 1 V1.1:20181005

Setting your Ventilation Requirement
Adjust the set ventilation with the Ventilation Rate Adjust button. The setting will cycle
through the different options below.
High ventilation - Fan will operate at high speeds across a wider range of
temperature to actively work on Air Quality and condensation.
Medium ventilation - Fan will operate optimal airflows (default).
Low ventilation - Fan will provide lower airflows while maintaining air quality.
Auto ventilation - Controller selects Low, Medium or High Ventilation
depending on the difference between the room temperature and your
comfort set temperature.
Low ventilation is suitable for low occupancy numbers in the house and when total
ventilation requirements may be substituted with opening windows and doors
(summertime).
Medium Ventilation (default) provides the ideal ventilation requirements for an
average well-insulated home.
High Ventilation is suitable when there is a higher occupancy in the home or signs of
poor air quality due to increased moisture levels in the house (condensation).
Auto mode maintains the requirements of the three rates based on temperature in the
home. As well as providing the correct levels of ventilation, the system also tries to
normalise the indoor air temperature to the target comfort level set by the user.
•
•
•
Frequently Asked Questions
Which ventilation rate should I choose?
I turned the controller off. Why does the system keep running?
When turning the controller off the fan enters a shutdown cycle which may take up to a
minute to turn off fully.
•
Wiring Diagrams
Fixed Wires
Com Volts -DC
12-24 Volts +DC
12 Volt AUX
Mode Output
Aux Air Source
NC
NC
7
6
5
4
3
2
1
4a
Controller (back)
4b
Page 2 V1.1:20181005

1a 1b2 3
Selecting the mounting location
The controller is for internal use only.
Mount approx. 1.5 metres above the floor on an inner wall. Select the wall for ease of
wiring to the fan.
Avoid locations which are not generally affected by changes in the room temperature.
Do not mount on hot surfaces or surfaces exposed to direct sunlight.
Do not install in damp or wet areas like the laundry or bathrooms.
•
•
•
•
•
Open the thermostat by pushing in the tabs located on the bottom of the unit
(figure 1a and 1b) and remove the interconnect cable.
Choose a mounting position on the wall and cut a 64 mm diameter hole in the
wall gib, avoiding any structure timber framing.
See Wiring Diagrams (figure 4a and 4b) for connections.
After connecting the required wiring, mount the base of the controller with the 4
screws provided (figure 2), noting the top direction.
Reconnect the interconnect cable to the display front.
Replace the cover by locating the two tabs at the top of the unit and lever the
touch screen on as shown (figure 3). As you close the unit ensure the two plastic
tabs at the bottom clip into place.
1.
2.
3.
4.
5.
6.
Note: Do not use excessive force to fit the cover.
Mounting Instructions & Installation
EVOAQ EC Fan (side)
RJ45 Connector
EVOAQ EC Fan (front)
Page 3 V1.1:20181005

This controller has been designed to only work with EVOVX Ventilation System EC
Fans
Set Temperature Range:
Temperature Resolution:
Operating Voltage/Frequency:
Sensing Element:
Operating Temperature:
Operating Humidity:
Output Control:
Display:
Approval:
EMC Approval:
5 - 35°C
0.5°C
12 - 24 Volt DC
NTC thermistor
0 to 40ºC
5 - 90% non-condensing
Digital control interface
3.5” digital LCD Touchscreen
All relevant AS/NZS standards
All relevant AS/NZS standards
Technical Specifications
Advanced controller functions
• Turn off your controller with the Power Off button.
• Press and hold the Ventilation rate adjust button for 5 seconds.
• Release the button when the screen turns on.
To calibrate your controller's room temperature you need to enter the programming mode
• Press the Power Off button to return to the home screen.
The temperature calibration value is shown in the middle of the display. Adjust the calibration
value using the Adjust Up and Down buttons.
• The controller will turn off after 5 seconds of no activity in programming mode.
The calibration value is added or subtracted (if negative) to the room temperature.
Example: The room temperature is 22°C and the controller displays 20°C. The
calibration value is -1°C change the calibration value to 1°C.
• To lock the controller press and hold the Adjust Up and Down buttons together.
• The Lock Symbol appears in the middle-left of the display.
• To unlock the controller repeat as above.
Locking the controller
The unit should be checked and the filter changed at least every 24 months.
Page 4 V1.1:20181005
Table of contents