Page | 1 User manual for evplug Fuse Box 7.4kW PN. EV40001 and EV40002 www.evplugchargers.com
EV FUSE BOX manual
Compatible with all 3.6 and 7.4kW EV chargers
7.4kW PN. EV40001 y EV40002
Features
Easy Plug and Play installation
FULLY WIRED complaining EURO Standards
Auto reclosing circuit
Lock with key
Charging plug meet IEC 62196-2 standard.
Excellent protection performance
Protection Grade IP65-Working condition.
Operating temperature: -30C to +50C
Rated voltage: 230V 1 phase
Current Max.: 32A
Components characteristics
1. Over voltage under-voltage protection: Surge
arrester (BY18-1+1): 1P, Imax=20kA, 275VAC,
with remote control
2. Over current protection Auto reclosing circuit
2P, 40A, C curve, 6kA
3. Leakage protection RCCB (KRC3): 1P+N, A
type, 40A,
30mA
4. Meter:230V, 5(40)A, 50Hz (Only in option
EV40002)
5. 4. Plastic box (WDB6): 6way, IP65 (EV40001)
Easy Plug and Play
installation
FULLY WIRED complaining
EURO Standards
Auto reclosing circuit
Lock with key
Page | 2 User manual for evplug Fuse Box 7.4kW PN. EV40001 and EV40002 www.evplugchargers.com
or Plastic box (WDB9): 9way, IP65 (EV40002)
Electric Performance
Rated Current and Voltage: 250V AC 32A
﹒Insulation Resistance: >1000MΩ(DC500V)
﹒Terminal Temperature Rise: < 50K
﹒Contact impedance: 0.5 mΩ Max
Wiring specification
Specification: 6mm²
Wiring diagram as:
•Fig 1.1 (PN. EV40001)
•Fig.1.2 (PN. EV40002)
Cautions
﹒DO not put the device in the water.
﹒DO not step on the box, do not pull it, do not
fold it up.
﹒Do not plug the fuse box into a electric
installation prepared for less than 7.4W or
electric current limit under 32 A.
﹒DO not drop the frontal door or put heavy
things on it.
﹒DO not place the fuse box near high-
temperature objects.
﹒DO not use the device in extreme
temperatures (normal operating range (-30C to
+50C).
﹒The power supply input cable should have at
least 6mm² with a standard 32A jack. It is
proposed to complete the distribution of
electricity by professionals.
﹒Make sure that the fuse box is free from any
signs of scratches, rust, cracks, etc.
﹒DO not charge if the fuse box is damaged,
rusted, cracked or loosely connected.
Warnings
﹒Carefully read these instructions and your
vehicle owner’s handbook before installing your
EV fuse box and EV charger
﹒Use only on the mains with fault current
circuit breaker.
﹒DO not use this product if the EV charging
cable is damaged.
﹒This is not a EV charger, use a EV charger
connected between this Fuse box and your
electric vehicle.
﹒For use with EV charging.
﹒The product must be grounded.
﹒DO not use this unit with an extension cord or
adapter.
﹒The unit contains no user serviceable parts.
DO not try to repair or service the device
yourself.
﹒If the unit does not work properly in
accordance with the operating instructions, do
not use this unit. Contact your dealer for a repair
or replacement.
﹒Use the product under normal away from high
temperature erosive materials or ignition source.
﹒DO not contact metal conductor to prevent
electric shock accident.
﹒Product shell is made of thermoplastic, please
do not pound it to avoid reducing performances.
Installation
1. Check the installation comply with the
national standards and the incoming
wiring are a minimum of 6mm2
(10mm2 if the distant between the
power supply and the fuse box is
longer than 8m)
2. Connect your EV charger bellows this
point.
3. Make sure that the power outlet
complies with.
Page | 3 User manual for evplug Fuse Box 7.4kW PN. EV40001 and EV40002 www.evplugchargers.com
Warranty:
Damage caused for the following reasons is
not covered by the warranty:
1. Improper handling, installation, use and
maintenance by the user.
2. Pulling the connector or wires
3. Product falls into the water.
This warranty is for the original purchaser
only and is NOT transferable.
PLEASE NOTE: This document includes the
latest information at the time of printing.
EVplug Chargers, S.L. reserves the right to
make changes to this product without
further notice. Changes or modifications to
this product by other than an authorized
service facility could void the product
warranty
Failure mode:
Fault identifies that there is an error in the
upload process.
It can occur for the following reasons:
1. Differential protection: Error in the
ground connection, connector, cables or
very humid or wet vehicle battery.
2. High or low voltage: the supply voltage is
too high or too low.
4. High current or short circuit in charging
circuit.
In the event of this error, unplug the
charger, turn up all switches and reconnect
it. In case the error persists, contact an
authorized electrical installer.
Assembled components:
Page | 4 User manual for evplug Fuse Box 7.4kW PN. EV40001 and EV40002 www.evplugchargers.com
MANUALS IN OTHER LANGUAGES
For manuals in any other language, please, read the following code or go to
https://evplugchargers.com/downloads/
Para manuales en otro idioma, por favor lea el siguiente código o vaya a
https://evplugchargers.com/downloads/
Pour les manuels dans une autre langue, veuillez lire le code ci-dessous ou allez sur
https://evplugchargers.com/downloads/
Für Handbücher in einer anderen Sprache lesen Sie bitte den Code unten oder
gehen Sie zu https://evplugchargers.com/downloads/
Per i manuali in un'altra lingua, leggere il codice qui sotto o andare su
https://evplugchargers.com/downloads/
Aby uzyskać instrukcje w innym języku, przeczytaj poniższy kod lub przejdź do
https://evplugchargers.com/downloads/
Başka bir dildeki kılavuzlar için lütfen aşağıdaki kodu okuyun veya
https://evplugchargers.com/downloads/ adresine gidin.

This manual suits for next models

1

Popular Industrial Equipment manuals by other brands

MCDonald 6480 quick start guide

MCDonald

MCDonald 6480 quick start guide

John Crane A Series Fitting & Maintenance Instructions

John Crane

John Crane A Series Fitting & Maintenance Instructions

Siemens BD2-AK 02 M2 Series installation instructions

Siemens

Siemens BD2-AK 02 M2 Series installation instructions

Titan 118 Installation, Maintenance, and Parts Manual

Titan

Titan 118 Installation, Maintenance, and Parts Manual

ABB HT576824 Operation manual

ABB

ABB HT576824 Operation manual

Bilanciai Cigiemme MERCURY PLUS instruction manual

Bilanciai

Bilanciai Cigiemme MERCURY PLUS instruction manual

Philadelphia Scientific HydroCart Max instructions

Philadelphia Scientific

Philadelphia Scientific HydroCart Max instructions

Still Trolley Mover Original instructions

Still

Still Trolley Mover Original instructions

Grundfos CR Installation and operating instructions

Grundfos

Grundfos CR Installation and operating instructions

Nederman HD100 instruction manual

Nederman

Nederman HD100 instruction manual

ABB AutoLink Mounting instructions

ABB

ABB AutoLink Mounting instructions

CHART ULTRADOSER 500S user manual

CHART

CHART ULTRADOSER 500S user manual

Conquip Concrete Coneflow Skip Series user guide

Conquip

Conquip Concrete Coneflow Skip Series user guide

ABB ReliaGear ND Installation, operation and maintenance manual

ABB

ABB ReliaGear ND Installation, operation and maintenance manual

Nexen AIR CHAMP Burke E. Porter 5H50P user manual

Nexen

Nexen AIR CHAMP Burke E. Porter 5H50P user manual

Siemens EBS SENTRON 3VM operating instructions

Siemens

Siemens EBS SENTRON 3VM operating instructions

PCB Piezotronics ICP 352C67 Installation and operating manual

PCB Piezotronics

PCB Piezotronics ICP 352C67 Installation and operating manual

ClockedIn OnTIme Hardware installation guide

ClockedIn

ClockedIn OnTIme Hardware installation guide

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.