exemys ID Series User manual


IDx User´s Manual Exemys
Exemys Products are in constant evolution to satisfy our customer’s needs.
For that reason, the specifications and capabilities are subject to change without prior notice.
Updated information can be found at www.exemys.com
Copyright © Exemys, 2005 All Rights Reserved.
Rev. 4.0.0
www.exemys.com Rev. 4.0.1 Página 2

IDx User´s Manual Exemys
Index
FEATURES 5
MODEL CODES 5
WORKING PRINCIPLE 7
RESET 7
AUTO TUNING 7
INDICATING LEDS 7
SENSIBILITY (SENS) 8
OUTPUTS 8
8.1 Pulsed______________________________________________________________ 8
8.2 Permanent while present ________________________________________________ 9
PRESENCE TIME (PRES) 9
FREQUENCY (FREC) 9
LOOP CONSTRUCTION AND INSTALLATION 9
CONNECTION 12
12.1 Connecting each model _______________________________________________ 12
TECHNICAL SPECIFICATIONS 13
FACTORY CONFIGURATION 13
GLOSSARY 14
www.exemys.com Rev. 4.0.1 Página 3

IDx User´s Manual Exemys
Figures
Figure 1 – Detail of the Codification of the models _________________________________________________5
Figure 2 – Available Models __________________________________________________________________6
Figure 3 – Pulsed output signal________________________________________________________________8
Figure 4 - Output signal permanent while present _________________________________________________9
Figure 5 – Loop construction ________________________________________________________________10
Figure 6 - Proper installation of the loop ________________________________________________________11
Figure 7 – Connection _____________________________________________________________________12
Figure 8 – Optoisolated outputs, Transistor, Relay and TTL. _________________________________________12
Figure 9 – Factory Configuration______________________________________________________________13
Tables
Table 1 – Indicating LED’s state _______________________________________________________________8
Table 2 - Sensibility ________________________________________________________________________8
Table 3 - Connection ______________________________________________________________________12
www.exemys.com Rev. 4.0.1 Página 4

IDx User´s Manual Exemys
Features
Microcontroller.
1 or 2 channels.
Switching power supply.
4 settable sensibility levels.
4 settable frequency levels.
Optoisolated, relay, transistor or digital outputs (TTL).
Safe output in case of failure.
Channel multiplexing.
Advanced failure analysis.
Auto-tuning.
Output while present
Drift compensation due to environmental fluctuations
Model Codes
IDX-XX-0-XX-
P
Activated while present
Normal Output
Output Type
Channels
Inductive Detector
(Optoailated Relay, Transistor or TTL)
(1 or 2)
Figure 1 – Detail of the Codification of the models
www.exemys.com Rev. 4.0.1 Página 5

IDx User´s Manual Exemys
PART NUMBER OUTPUTS CHANNELS
ID1-RL-0-NA-P
ID2-RL-0-NA-P
ID1-RL-0-NC-P
ID2-RL-0-NC-P
ID1-OP-0-NOFF-P
ID2-OP-0-NOFF-P
ID1-OP-0-NON-P
ID2-OP-0-NON-P
ID1-TR-0-NOFF-P
ID2-TR-0-NOFF-P
ID1-TT-0-N0-P
ID2-TT-0-N0-P
Normally Open Relay
Optoisolated Normally OFF
TTL Normally OFF
TTL
Normally Open Relay
Normally Closed Relay
Normally Closed Relay
Optoisolated Normally OFF
Optoisolated Normally ON
Optoisolated Normally ON
Transistor Normally OFF
Transistor Normally OFF
Normally OFF
1
2
1
2
1
2
1
2
1
2
1
2
Figure 2 – Available Models
www.exemys.com Rev. 4.0.1 Página 6

IDx User´s Manual Exemys
Working Principle
The IDx detects metallic masses measuring the inductance of a loop.
This loop is part of an oscillating circuit that generates a magnetic field. When a vehicle passes
over the loop the oscillator’s frequency changes. The IDx’s microprocessor detects these changes
and, depending on its configuration, generates the corresponding output.
Reset
The RESET button is used to configure the IDx with the DIP SWITCH’s settings.
Every time the settings are changed the RESET button must be pressed.
Auto Tuning
When the IDx is turned on, the auto tuning process begins which determines the reference level.
During this process, the indicating leds are turned on.
The environmental fluctuations produce frequency changes which are compensated due to the
auto tuning process.
Indicating Leds
The IDx has three indicating leds. The channel leds turn on when a vehicle is detected and remain
this way until the vehicle has completely left the loop.
Apart from indicating a vehicle’s presence, these leds indicate channel failure.
www.exemys.com Rev. 4.0.1 Página 7

IDx User´s Manual Exemys
Table 1 – Indicating LED’s state
Led CH1 and CH2 STATE
1 Flash Short-circuit in loop
2 Flashes Disconnected loop or frequency too low.
3 Flashes Frequency too high
Led on Vehicle detection
Sensibility (SENS)
Each channel has 4 configurable sensibility levels. This sensibility is specified as δL/L [%]: the
minimum change (δL), the loop’s inductance must suffer, divided the loop’s inductance (with no
vehicle present). A cars typical sensibility is δL/L=3% approximately.
Table 2 - Sensibility
SENSIBILITY δL/L %
Low 0.50
Medium 0.10
High 0.05
Very High 0.02
Outputs
8.1 Pulsed
The output signal activates when the vehicle enters the loop and remains on for 120 ms
approximately.
120 ms
Vehicle over the loop
OUTPUT
LED
Figure 3 – Pulsed output signal
www.exemys.com Rev. 4.0.1 Página 8

IDx User´s Manual Exemys
8.2 Permanent while present
The output signal activates when the vehicle enters the loop and remains on while the vehicle
crosses the loop.
Vehicle over the loop
OUTPUT
LED
Figure 4 - Output signal permanent while present
Presence Time
(PRES)
Regardless of the output signal type (pulsed or permanent while present), if a vehicle remains
over the loop longer than a certain amount of time, the IDx will reset, causing a re-tuning. This
period of time, called
presence time
, depends on the size of the metallic mass that’s being
detected. A car will reset the IDx after remaining over the loop for approximately an hour.
Frequency
(FREC)
You can choose the working frequency of both channels to avoid interference with other
detection systems. Frequencies differ from each other around 5%.
The frequency will depend on the loop’s geometry. The detector works with frequencies from
25Khz to 120KHz. Above or below those frequencies the detector will indicate failure. To avoid
interference between the IDx’s channels, detection on each channel is done separately. When
detection is taking place in one channel the other one is off, this way mutual interference is not
possible. The IDx switches from one channel to the other with enough speed as not to affect
normal operation.
Loop construction and installation
The wire used for the loop must reach the detector module without cuts. The ends of the wire are
brought back to the enclosure. This sector of wire must be twisted, at least 25 turns per meter ( 8
per feet), and it can’t exceed 100m (330 feet). If the cut in pavement is shared by the channels,
increasing the number of turns per meter and using shield wires is recommended (shield must be
ground connected in detection module).
www.exemys.com Rev. 4.0.1 Página 9

IDx User´s Manual Exemys
The loop, unless under prohibitive conditions, should be rectangular. Shorter sides should follow
traffic flow. Longer sides must be separated at least 1 meter (3 feet).
Wire section must be 1.5 mm square (14/16 AWG) or above. The wire may be multi core with
silicon jacket.
Figure 5 – Loop construction
25 turns / meter (8 turns / feet)
100 m (330 feet) Maximum
Examples on loop size and number of turns:
Standard Loop
2m x 1m (6.5 x 3 feet), 3 turns
When installing two loops, of different detection modules, at close ranges you should choose
different working frequencies for each loop, to avoid interference. In any case, loops should be at
least two meters apart. When both loops are connected to the same IDx this restriction doesn’t
apply.
The loop is installed in a cut in pavement. The cuts should be wider than the diameter of the wire
used to form the loop; the depth should be N x wire’s diameter + 20 mm (1/8 “) or deeper (where
N is the number loop’s of turns). Cutting the rectangle’s corners at a 45º angle helps avoid
curving the wire beyond the maximum curve-diameter.
Proper installation of the loop will result in optimal detection. If a loop fails, it can’t be repaired
due to the installation method.
www.exemys.com Rev. 4.0.1 Página 10

IDx User´s Manual Exemys
Traffic Flow
Pavement Cuts
Sealer
LOOP
PAVEMENT
Figure 6 - Proper installation of the loop
Fill the pavement’s cuts with epoxy resin, avoiding moisture or other materials since this could
affect the measurements.
When placing a new loop, remove the old one. If this is not possible separate and isolate the wire
ends.
www.exemys.com Rev. 4.0.1 Página 11

IDx User´s Manual Exemys
Connection
10
11
2
6
4
3
57
8
9
LOOPS
10-30 VDC
CHASIS GROUND
OUTPUT 1
OUTPUT 2
2
1
+
-
Figure 7 – Connection
12.1 Connecting each model
OPTOISOLATED
(OP)
7 y 10
8 y 11
TRANSISTOR
(TR)
7 y 10
8 y 11
RELAY
(RL)
TTL
(TT)
7
y
10
8
y
11 7
y
10
8
y
11
Figure 8 – Optoisolated outputs, Transistor, Relay and TTL.
Table 3 - Connection
Pin Description
1 + Vdc (10-30V)
2 GND
3 Loop Channel 1
4 Loop Channel 1
5 Loop Channel 2
6 Loop Channel 2
7 Relay output 2 (NA-NC) / Opto + / TR+ / GND
8 Relay output 2 (Common) / Opto - / GND / TTL
9 Chassis ground
10 Relay output 1 (NA-NC) / Opto + / TR+ / GND
11 Relay output 1 (Common) / Opto - / GND / TTL
www.exemys.com Rev. 4.0.1 Página 12

IDx User´s Manual Exemys
Technical Specifications
Power Supply 10-30 Vdc, internal switching power source.
Operating current 100mA max.
Relay 0.5ª 120Vca, 1ª 24Vdc, 0.3ª 60Vdc.
Optoisolators Optoisolated output, 30V max, 10mA max.
Transistor Transistor output, 30V max, 100mA max.
TTL Digital output TTL (0-5V)
Protections Varistors in power supply and relay outputs. Lightning protection and ground
terminators. Loop input isolation with transformer.
Inductance range 20uHy a 2000uHy. Factor Q>5
Frequency range 25Khz a 120Khz
Presence time 1hour for δL/L = 3%
Sensibility δL/L = 0.02%, 0.05%, 0.1%, 0.5%
Mux time 10mS
Enclosure Polycarbonate (top) y Noril (base), UL94-V0, Grey RAL 7035.
Factory Configuration
ON
LOW
MEDIUM
HIGH
VERY HIGH
SENS. CH 1
SENS. CH 2
FRECUENCY
PRESENCE
ON
8
7
6
5
4
2
1
Figure 9 – Factory Configuration
www.exemys.com Rev. 4.0.1 Página 13

IDx User´s Manual Exemys
Glossary
Drift:
Frequency change due to environmental fluctuations.
Delta L/L (δL/L):
change in the loop’s inductance caused by an object over it, divided the loop’s
inductance without objects over it.
Loop:
wire wound in a given shape, placed in the detection zone.
Startup:
process that takes place when the detector is turned on, or when RESET is pressed, in
which the settings of the DIP SWITCH are read and the reference level is determined.
Led: Light emitting diode
Sensibility:
signal level that produces a detection output. Usually expressed in δL/L.
Presence time:
Maximum activation time of a loop before the detector resets.
www.exemys.com Rev. 4.0.1 Página 14
This manual suits for next models
12
Table of contents
Popular Security Sensor manuals by other brands

Timeguard
Timeguard SLW360 Installation & operating instructions

Hellermann Tyton
Hellermann Tyton TopTronic T175HP manual

KraftPowercon
KraftPowercon PRM1 Series manual

Abus
Abus SHMK10000 quick guide

C.P. Electronics
C.P. Electronics MWS3A-AD installation guide

Resolution
Resolution DSC-Compatible NanoMax RE322 instructions