Exide Inverterz Magic 12V 700VA User manual

USER MANUAL
EXIDE INVERTERZ
For any service related issue
call our Toll Free No. 1800–103–5454
Exide Industries Ltd.
59E, Chowringhee Road, Kolkata – 700 020

Dear Valued Customer,
We congratulate you for your excellent choice of our Exide Inverterz. Exide Inverterz
will provide you complete comfort during the absence of utility power and provide
your appliances the exact replication of mains supply because of the latest
Technology.
The salient features of EXIDE INVERTERZ MAGIC are
• Controlled Output Voltage
• Automatic Battery Charge Management
• Dual Mode of Charging i.e. Normal & Fast Charging Rates through Touch
Switch
• LED Indications for better user interface
• Automatic Overload, Battery Low, Over Temperature & Short Circuit
protection sense
• Wide Mains Voltage Charging Range i.e. 100V – 290V
• Mains Low Voltage Charging Facility
• Manual Mains Bypass Facility
• Great Power Saving
• Easy to Service
• No Humming Noise
This manual provides you thorough understanding of your Exide Inveterz and its
optimum use.
Please read installation and operating instructions in the manual carefully. Before
installing and using you EXIDE INVERTERZ. Pay special attention to the CAUTION
and WARNING statements in this manual.

About the EXIDE INVERTERZ MAGIC
Exide Inverterz Magic transforms Direct Current (DC) to Alternating Current (AC).
The battery acts as a reservoir ensuring continuous supply when utility power is not
available.
Controls
Front Panel
Graphic Description
Indication
Meaning
MAINS ON
Continuous Glow
Mains Present
Blinking with beep sound
Thermal Circuit Breaker trip
BACK-UP ON
Continuous Glow
Back-up ON
BATTERY LOW
Continuous glow with beep sound
Battery Voltage Low
Continuous glow without beep sound
Battery Voltage Low Cut
CHARGING/ CHARGED
Blinking
Battery Charging
Continuous Glow
Battery Charged
OVERLOAD/ SHORT
CIRCUIT
Blinking with beep sound
Overload Alarm
Blinking without beep sound
Shutdown
Continuous glow with beep sound
Short Circuit
ON/ OFF – ON
ON/ OFF Switch LED Glow
Inverterz ON
ON/ OFF - OFF
ON/ OFF Switch LED Not Glow
Inverterz OFF
FAST CHARGING
Fast Charging Switch LED Glow
Fast Charging Mode
NORMAL CHARGING
Normal Charging Switch LED Not Glow
Normal Charging Mode
UPS MODE
UPS Mode Switch ON LED Glow
UPS Mode Operation

Rear Panel
Exide Inverterz Magic has two battery wires coming out from the rear side, a
Thermal Circuit Breaker 7Amp for 800VA, 875VA & 1125VA and 10Amp for 1625VA,
output socket and a three pin top power cord to connect with mains supply. Red
coloured battery wire is to be connected to positive terminal of battery and black
coloured wire to be connected to negative terminal of the battery. Manual/Bypass
switch, if Inverterz faulty, than select Bypass selection.
Caution: Do not reverse the battery connections, it will blow the DC fuse
connected in series with battery connection inside the Power Card

Some Safety Measures
Important Precautions
The output side of the AC wiring of Exide Inverterz should never be connected to
utility power or a DG set. This condition is far worse than a short circuit. If the unit
survives this condition, it will shut down until connections are made.
Installation should ensure that the AC output of Exide Inverterz should not be
connected to AC input.
Note: Connecting the battery cables to the Exide Inverterz battery terminals
may cause spark, usually accompanied by a “snap”. This is normal, don’t let it
scare you.
Never disconnect battery cables while the Exide Inverterz is delivering power
or battery charger is operating. Always turn the switch off first.
General Precautions
• Before installing, connecting any wiring or using the Exide Inverterz, read all instructions
of this instruction manual.
• CAUTION: Do not install or connect batteries to this unit unless instructed to do so.
Failure to comply with this instruction can cause damage or complete failure of the unit.
• CAUTION: To reduce risk of injury, use only deep-cycle lead acid batteries.
• Do not expose the system to rain, snow or liquids of any type. Do not disassemble the
system; call EXIDE authorised service centre when service or repair is required. In
correct reassembly may result in a risk of electric shock or fire.
• To reduce risk of electric shock, disconnect all the wiring from the system before
attempting any maintenance cleaning. Turning off the system will not reduce this risk
• WARNNING: WORKING IN VICINITY OF A LEAD ACID BATTERY IS DANGEROUS.
• Be extra cautious when working with metal tools on, or around batteries. The potential
exists to drop a tool and short-circuit the batteries or other electrical parts resulting in
sparks that could cause an explosion
• Do not leave batteries in discharge state for more than a day or two. They will undergo a
chemical process called sulfation which can permanently damage the battery. Also
batteries will self-discharge over a period of 3-6 months, so they should periodically
recharge even if they are not being used.
• GROUNDING INSTRUCTIONS: The Exide Inverterz should be connected to a
grounded, permanent wiring system.

• Someone should be your audible range to come to your aid when you work near
batteries.
• Have plenty of fresh water and so nearby in case battery acid contacts skin, clothing or
eyes
• Wear complete eye protection and clothing protection. Avoid touching eyes while
working near batteries. Wash hands when done.
• If battery acid contacts skin or clothing, wash immediately with soap and water. If acid
enters eyes, immediately flood eyes with running cool water for at least 15minutes and
get medical attention immediately.
• Never attempt to charge a frozen battery.
• Before touching battery terminal makes sure that the system front system is OFF and
AC mains to the Exide Inverterz are also OFF.
• NEVER smoke or allow spark or flame in vicinity of the batteries.
• Remove personal metal items such as rings, bracelets, necklaces and watches when
working electrical circuit. These items can cause a short circuit current high enough to
weld a ring and may cause severe burns
• If it is necessary to remove any battery, always remove the grounded terminal from the
battery first. Make sure all the accessories are off, so as not to cause arcing. Be sure
that the area around the battery is well ventilated.
• Clean battery terminals. Be careful not to allow corrosion to come in contact with eyes.
• Study all battery manufacturers’ specific precautions and recommended rate of charge.
• Add only distilled water in each cell until battery acid reaches level specified by the
battery manufacturer. This helps purge excess gas from cells. Do not over fill. For a
battery without caps, carefully follow manufacturer’s charging instructions.
• CATUION: The EXIDE INVERTERZ should be connected to grounded, permanent
wire system.
SPECIAL NOTICES:
1. The Exide Inverterz charge is for use with a nominal supply voltage of 12V/ 24V DC.
2. No AC or DC disconnects are provided as an integral part of this system.
3. No over current protection for the battery supply is proved as an integral part of this
system. Both AC & DC disconnects must be provide as part of the system installation.
4. No over current protection for the AC output wiring is provided as an integral part of the
system. Over current protection of the AC output wiring is prided as part of the system
installation.
Personal Precautions

CHARGING MODE
PARAMETER
SPECIFICATIONS
MAGIC 12V
800VA
MAGIC 12V
875VA
MAGIC 12V
1125VA
MAGIC 24V
1625VA
Fast Charging Current
13Amp ±
1.5Amp
14Amp ±
1.5Amp
17Amp ±
1.5Amp
17Amp ±
1.5Amp
Normal Charging Current
9.5Amp ±
1.5Amp
10Amp ±
1.5Amp
12.5Amp ±
1.5Amp
12.5Amp ±
1.5Amp
Battery Boost Voltage
14.4V ± 0.2V
28.8V ± 0.4V
Battery Float Voltage
13.7V ± 0.2V
27.4V ± 0.4V
LOAD CHART *
Model
800VA
875VA
1125VA
1625VA
Options
A
B
C
D
A
B
C
D
A
B
C
D
A
B
C
D
Computers (TFT)
0
0
0
1
0
0
0
1
0
0
0
2
0
0
0
3
Printer (Laser)
0
0
0
1
0
0
0
1
0
0
0
1
0
0
0
1
TV (LCD 26")
0
0
1
0
0
0
1
0
0
0
1
0
0
0
1
0
Tube light (40W)
4
0
5
3
5
0
6
3
7
0
8
6
9
0
8
2
Fan (80W)
5
0
4
3
5
0
4
4
6
0
5
4
10
0
10
5
CFL (15W)
5
42
6
7
6
46
7
6
9
60
10
6
9
86
10
6
* Depending on the actual VA rating/technical specifications of the appliance. Specifications
are subject to change without prior notice due to constant R&D effort. Accessories show in
the picture is not the standard part of the product.
APPLICATION CHART EXIDE INVERTERZ*
Back-up Power of electrical loads:
• Computer & Printer
• Fan, Tubelight CFL, LED Light
• T.V. Sets, DVD & Music System
*Ideal for Computer & Printer.

Where to install
The system should be installed in a location that meets the following requirements:
a) Dry – Do not allow to water to drip or splash on the Exide Inverterz
b) Cool – The ambient air temperature around the system should be between
00C to 450C (320F to 1130F). Cooler environment is better for the system.
c) Ventilation: Allow at least two inches (5cm) of clearance around the system
for air flow.
d) Safe: DO not install the Exide Inverterz in the same compartment as
batteries or in any compartment which are storing flammable liquids such as
gasoline.
e) Close to battery - Install the system as close to the battery as possible in
order to minimise the length of cable required to connect the system to the
battery. It is better and cheaper to run longer AC wires than longer DC
cables.
CAUTIONS! To prevent fire, do not cover or obstruct ventilation openings. Do
not install the system in a zero - clearance compartment. Overheating may
result.
WARNNING! This equipment contains components which tent to produce arcs
or sparks. To prevent fire or explosion do not install in compartment
containing batteries or flammable materials or in locations which require
ignition protected equipment.
Installation

How to Install
DC Cabling:
1. Ensure that the ON/OFF switch on the front panel of the Inverterz if OFF
position before you begin the installation.
2. Connect the negative terminal of the battery to the thick black wire of system
3. Connect the positive terminal of the battery to the thick red wire of system
AC Cabling:
Plug in the power cord to the mains socket on the wall. The cabling should have
proper earthing. Connect AC input supply to the 3 way terminal of the system such
that the line is connected to ‘L’, neutral is connected to ’N’ and earth is connected
to ‘E’. Input supply should remain ON once the system is installed. Take out from
output socket.

Once the AC and DC wiring have been installed and connected, take a moment to
go re-examine all the connections and make sure they are secured and in the
proper terminals.
1. Check to see that the Exide Inverterz is turned off and then apply battery
(DC) power to it. Ensure that all wiring has been installed properly. Next turn
On the battery bank DC disconnects or connect the proper fuse in line to the
battery to compete the battery circuit.
2. Put ON/OFF switch to the ON position. This system should run a load
without AC input (battery only). Place a load on the system and make sure it
works.
3. To charge your batteries connect AC power to the system by lugging in the
AC power and turning on the mains line. This shows that charger is working
properly. Any AC load powered by the system should also work at this point
since a portion of the AC power is passed through this Exide Inverterz to
power the loads.
4. Disconnect the AC power the system should transfer to battery mode
immediately. This will be indicated by clicking sound as the internal transfer
relay changes position.
5. The system will begin to take power from the batteries and use it to power
the load. And the load continues to operate uninterrupted.
The above steps will complete the functional test of the Exide Inverterz. If all areas
pass, the system is ready for use. If something fail figure out the reason before
proceeding or contact the service centre
Note: Manual / Bypass switch selection should be manual mode, if Inverterz faulty,
than select Bypass selection.
Very little maintenance is required to keep your Exide Inverterz Magic operating
properly. You should clean the exterior of the unit periodically with a damp cloth to
prevent accumulation of dust and dirt
Start Operation
Maintenance

Problems and Symptoms
Possible Cause
Solution
No Output voltage
No Indication
Poor battery condition or
battery connection loose
Use new battery or make
proper connections
No output voltage
Overload indication
Excess Load Applied
Reduce the excessive load
from the Exide Inverterz &
reset by ON/OFF Switch
No output voltage
All LED Blinking
Thermal shut down
Call the service support. There
is overheat problem in the
system
Mains LED Blinking with
Buzzer
Thermal Circuit Breaker Trip
Reset Thermal Circuit Breaker
Mains ON but Not Charging
UPS/ Normal Selection
switch may be in UPS mode
Check Mains voltage &
Selection of Normal / UPS
mode as per specified voltage
range
Mains ON but Not Charging
Bypass Switch may by in
Bypass Mode
It should be in Manual Mode
while Inverterz is OK
Troubleshooting Guide

Technical Specifications
Model with Rating
Parameters
MAGIC
12V 800VA
MAGIC
12V 875VA
MAGIC
12V 1125VA
MAGIC
24V 1625VA
No Load Output Voltage
235V ± 5V
Output Frequency
50Hz ± 1Hz
Output Wave Form
Modified Square Wave
Nominal Battery Voltage
12V
24V
Battery Low Cut Off
10.5V ± 0.2V
21.0V ± 0.4V
Mains Input Voltage Range
(at Normal Mode)
100V - 290V ± 10V
Mains Input Voltage Range
(at UPS Mode)
180V - 265V ± 10V
Changeover Time - Mains to
Back-up (UPS Mode)
≤10 msec
Changeover Time - Back-up
to Mains (UPS Mode)
≤10 msec
Changeover Time - Mains to
Back-up (Normal Mode)
≤40 msec
Changeover Time - Back-up
to Mains (Normal Mode)
≤10 msec
Specifications
Other manuals for Inverterz Magic 12V 700VA
1
This manual suits for next models
3
Table of contents
Other Exide UPS manuals