PACK CONTENTS
REQUIRED
MOUNTING/ INSTALLATION STEPS
x1 x1 x1 x1 x1 x1
x1x1 x1 x1 x2
M4 x 14mm
(For Euro conduit box
installation)
M3 x 20mm
(For ceiling mout
installation)
Hole saw size:
Ф75mm - 80mm
M3 x 15mm
(For cable clamps
installation)
x2
x4
Surface Mount
1
4
2
5
3
6
7
9
8
I
5mm
4mm
No 2
Phillips
3mm
0FF
230V
ij
5mm
50.8mm or 60mm
60mm
50.8mm
CAUTION:
OR
OR
‘CLICK’ ‘CLICK’ ‘CLICK’
Switch OFF the electricity at the fuse box by
removing the relevant fuse or switching off the circuit
breaker before proceeding with the installation.
IMPORTANT
L1L2LN
Wiring diagram
Connect the mains supply
cable to the terminal block on
the backplate as follows.
Connect the cable from the
lighting load to the terminal block
on the backplate as follows.
Note: Remove the external link
between L and L2
( See connection diagram )
Option1
Connection:
L
N
Live Brown
L1 Switched Live White
Neutral Blue
Earth Green / Yellow
L
N
Live Brown
L1 &
L2
Relay contact
for external load White
Neutral Blue
Earth Green / Yellow
The device needs
20-50 seconds to
warm up.
x2 x2
1 x 2.5mm²
Cable entry
capability at
terminal block
2 x 1.0mm²
2 x 1.5mm²
Cut out
here
N
NL
μ
L2 L1
L
Option2
* Remark: L1 & L2 is relay output N
NL
L2 L1
L
L1
L2
μ
LS1000R LightSpot 360° Dual Mount PIR installation and operating instructions
Only suitably qualified personnel should install this equipment
!!
Haydock Lane
Haydock
Merseyside
WA11 9UJ
UK
www.ex-or.com
Technical Support
+44 (0)1942 719229
WALK TESTING
1 3
Activate Manual Override Operation
MANUAL OVERRIDE OPERATION
SWITCHABLE LOAD
TECHNICAL SPECIFICATIONS
Detection Range:
Detection Angle:
Power Supply:
Maximum Switchable Load:
Time On Adjustment:
Dusk Level Adjustment:
Operating temperature:
Environment Protection:
Up to 6 metres diameter (3m Radius)
at mounting height of 2.5m
360°
220 ~ 240 VAC / 50 Hz
Max load current 6A
Incandescent / Halogen Max 2000W
Flourescent lamp (magnetic) Max 500W
Flourescent lamp (electronic ballast) Max 400W
Low energy (CFL) Max 120W
LED lamp Max 110W
Fan Max 75W
5 seconds - 15 minutes
Day & night or night only operation
-20 to 40°C
For ceiling mount - IP44
For flush mount - IP44 (at sensor portion only)
- IP20 (ceiling board onwards)
Max 400W
Max 500W
Max 2000W Max 120W
Max 110W
Max 75W
2
MIN. SUN.
warm up
20-50 SEC
Around
10 second
Lamp turn on
when reach Lux
setting level.
ON
OFF
ON
2 times within 2 seconds
DUSK
DAWN
Hrs
2 SEC
5
SEC
1
Deactivate Manual Override Operation
Manual deactivation before dawn
2Auto deactivation when
dusk to dawn ON
Lamp turn off when
dusk to dawn.
OFF
ON
1 time within 1 second
1 SEC
5
SEC
OR
Auto Mode
Auto Mode
ON
MOUNTING/ INSTALLATION STEPS
Flush Mount
REMOVING
Surface Mount
REMOVING
Flush Mount
‘CLICK’
6 7 8
4Opening hole
75mm~80mm diameter
Ceiling board
thickness
5mm-20mm
Power wire
9
‘CLICK’
Ceiling board The device need
20-50 seconds to
warm up.
5
1 2 3
0FF
230V
Switch OFF the electricity at the fuse box by
removing the relevant fuse or switching off the circuit
breaker before proceeding with the installation.
IMPORTANT
L1L2LN
* Remark: L1 & L2 is relay output
Wiring diagram
Connect the mains supply
cable to the terminal block on
the backplate as follows.
( See connection diagram )
Option1
Connection:
L
N
Live Brown
L1 Switched Live White
Neutral Blue
Earth Green / Yellow
N
NL
μ
L2 L1
L
Connect the cable from the
lighting load to the terminal block
on the backplate as follows.
Note: Remove the external link
between L and L2
L
N
Live Brown
L1 &
L2
Relay contact
for external load White
Neutral Blue
Earth Green / Yellow
Option2
N
NL
L2 L1
L
L1
L2
μ
1 x 2.5mm²
Cable entry
capability at
terminal block
2 x 1.0mm²
2 x 1.5mm²
TOP VIEW
3 METRE
3 METRE 3 METRE
3 METRE
MOTION SENSOR DETECTION
When mounting
at 2.5m height
Dia. 6 METRE
SIDE VIEW
PERSPECTIVE VIEW
2.5 M
1 M
3 METRE 3 METRE
10
20
30
40
°C
40
LENS MASK
Lens mask
sticker
Restrict
short
detection
Restrict
long
detection
Restrict
detection
directly
under
sensor
Adjustment
15 MIN
SEC
-Can be adjusted by flat head screwdriver.
5 SEC
MIN
15
ON-TIME LUX
TESTING & OPERATION
10
20
30
40
°C
40
10
20
30
40
°C
40

Other Exor Security Sensor manuals

Exor MLS CONNECT MLS2000CDR Installation and operation manual

Exor

Exor MLS CONNECT MLS2000CDR Installation and operation manual

Exor LR15 Installation and operation manual

Exor

Exor LR15 Installation and operation manual

Exor MLS2000PF Installation and operation manual

Exor

Exor MLS2000PF Installation and operation manual

Exor MS1001F Installation and operation manual

Exor

Exor MS1001F Installation and operation manual

Popular Security Sensor manuals by other brands

Omron F3W-D052A instruction sheet

Omron

Omron F3W-D052A instruction sheet

Seago Premium Stainless Steel Liftraft Cradle quick start guide

Seago

Seago Premium Stainless Steel Liftraft Cradle quick start guide

PRASTEL FOTOTEST/2 manual

PRASTEL

PRASTEL FOTOTEST/2 manual

Sealey VS600.V2 instructions

Sealey

Sealey VS600.V2 instructions

Nortek GoControl user guide

Nortek

Nortek GoControl user guide

Powerfix Z31174 Operation and safety notes

Powerfix

Powerfix Z31174 Operation and safety notes

F&F DRM-02 quick start guide

F&F

F&F DRM-02 quick start guide

Siemens Cerberus CS1140 Commissioning

Siemens

Siemens Cerberus CS1140 Commissioning

BAPI BA/LDT Termination and Troubleshooting

BAPI

BAPI BA/LDT Termination and Troubleshooting

Ecolink WST-621v2 installation manual

Ecolink

Ecolink WST-621v2 installation manual

Visonic K-940 installation instructions

Visonic

Visonic K-940 installation instructions

Crow BS-1 Installation instructions & user manual

Crow

Crow BS-1 Installation instructions & user manual

UTC Fire and Security Det-Tronics Dual Spectrum PM-5MPX instructions

UTC Fire and Security

UTC Fire and Security Det-Tronics Dual Spectrum PM-5MPX instructions

Waters ACQUITY QDa Overview and maintenance guide

Waters

Waters ACQUITY QDa Overview and maintenance guide

GJD D-TECT Walktester GJD380 Installation & user guide

GJD

GJD D-TECT Walktester GJD380 Installation & user guide

Firefly OMNIGUARD 540 Operating and service manual

Firefly

Firefly OMNIGUARD 540 Operating and service manual

SKF TMEH 1 Instructions for use

SKF