CAUTION
MODELS • VCDD010I• VCDD015I
VCDD020I• VCDD025I• VCDD030I
Page 1
READ AND SAVE THESE INSTRUCTIONS
TO REDUCE THE RISK OF FIRE, ELECTRICAL SHOCK, OR
INJURY TO PERSONS, OBSERVE THE FOLLOWING:
1. Use this unit only in the manner intended by the manufac-
turer. If you have questions, contact the manufacturer at the
address or telephone number listed in the warranty.
2. Before servicing or cleaning unit, switch power off at service
panel and lock the service disconnecting means to prevent
power from being switched on accidentally. When the serv-
ice disconnecting means cannot be locked, securely fasten
a prominent warning device, such as a tag, to the service
panel.
3. Installation work and electrical wiring must be done by a
qualified person(s) in accordance with all applicable codes
and standards, including fire-rated construction codes and
standards.
4. Sufficient air is needed for proper combustion and exhaust-
ing of gases through the flue (chimney) of fuel burning
equipment to prevent backdrafting. Follow the heating
equipment manufacturer’s guideline and safety standards
such as those published by the National Fire Protection
Association (NFPA), and the American Society for Heating,
Refrigeration and Air Conditioning Engineers (ASHRAE),
and the local code authorities.
5. When cutting or drilling into wall or ceiling, do not damage
electrical wiring or other hidden utilities.
6. Ducted fans must always be vented to the outdoors.
7. To reduce the risk of fire, use only metal ductwork.
8. If this unit is to be installed over a tub or shower, it must be
marked as appropriate for the application and be connected
to a GFCI (Ground Fault Interrupter) - protected branch
circuit.
9. Never place a switch where it can be reached from a tub or
shower.
10.This unit must be grounded.
1. For general ventilation use only. Do not use to exhaust
hazardous or explosive materials and vapors.
2. To avoid motor bearing damage and noisy and/or unbal-
anced impellers, keep drywall spray, construction dust, etc.
off power unit.
3. Please read specification label on product for further
information and requirements.
WARNING
IN-LINE
VENTILATORS
TABLE OF CONTENTS
This manual is divided into sections as follows:
•“TYPICAL INSTALLATION”
This section shows a common installation in new and
existing frame construction.
- Mounting (New Construction)
- Mounting (Existing Construction)
- Wiring
- Ducting (Straight-Through Blower Discharge)
•“MOUNTING OPTIONS”
•“WIRING OPTIONS”
- Wiring Plate Position
•“DUCTING OPTIONS”
- Blower Discharge Positions
- Ducting (Right-Angle Blower Discharge)
•“USE AND CARE”
•“SERVICE PARTS”
•“WARRANTY”
MODELS • VCDD010I• VCDD015I
VCDD020I• VCDD025I• VCDD030I
Page 2
TYPICAL INSTALLATION TYPICAL INSTALLATION
MOUNTING (New Frame Construction)
Factory-shipped unit installed in new construction.
MOUNTING (Existing Frame Construction)
Factory-shipped unit installed in existing construction.
* VCDD010I& VCDD015Iuse 6” round duct.
VCDD020I, VCDD025I& VCDD030Iuse 8” round duct.
Two ways to connect ductwork to a factory-shipped unit.
* VCDD010I& VCDD015Iuse 6” round duct.
VCDD020I, VCDD025I& VCDD030Iuse 8” round duct.
IMPORTANT:
Remove shipping tape from damper
Remove the shipping tape from the damper flap and make sure
that damper flap opens and closes freely inside the ductwork.
Use duct tape to make ductwork connections secure and air-tight.
Remove shipping ring from blower inlet
Remove the shipping ring from the blower inlet before
operating the ventilator.
WIRING
Ventilator can be wired from outside of housing.
Use UL approved connectors to wire per local codes.
DUCTING (Straight-Through Blower Discharge)
ROUND DUCT*
ADDITIONAL
1½” FRAMING
MOUNTING
SCREW
Mounting brackets
factory-shipped in
position for ½”
ceiling material.
CEILING JOIST
(16” centers shown)
Blower factory-shipped
in straight through
discharge position.
2 X 4 FRAMING
(wide side down)
ROUND DUCT*
CEILING JOIST
(16” centers
shown)
FINISHED
CEILING
MATERIAL
MOUNTING
BRACKETS
(Attached to
opposite sides
of housing &
upside-down)
BLACK
TO
BLACK
WHITE
TO
WHITE
GROUND TO
WIRING PLATE
TOP / BACK
OF HOUSING
WIRING
PLATE
120 VAC LINE IN
ROOF CAP
ROUND DUCT*
ROUND
ELBOW*
WALL
CAP
MODELS • VCDD010I• VCDD015I
VCDD020I• VCDD025I• VCDD030I
Page 3
MOUNTING OPTIONS DUCTING OPTIONS
DUCTING (Right-Angle Blower Discharge)
BLOWER DISCHARGE POSITIONS
Typical ductwork connection to a ventilator
converted to right-angle discharge.
* VCDD010I& VCDD015Iuse 6” round duct.
VCDD020I, VCDD025I& VCDD030Iuse 8” round duct.
USE AND CARE
Ventilator is designated for continuous operation. If desired, it
may be controlled using an on/off switch or a solid-state,
variable speed control. Follow wiring instructions packed with
control, and adhere to all local and state codes, and the
National Electrical Code.
WARNING: To reduce the risk of electric shock,
disconnect from power supply before servicing.
To clean grille: Use appropriate vacuum attachment or
remove grille and clean with a soft cloth and mild soap or
detergent. Dry grille thoroughly before reinstalling.
To clean blower assembly: Remove grille, unplug blower from
housing, remove blower mounting nuts, and carefully remove
blower from housing. Use appropriate vacuum attachment or a
soft cloth and mild soap detergent to clean blower discharge
area and wheel. NO NOT ALLOW WATER TO ENTER MOTOR.
Make sure blower assembly is completely dry before reinstalling.
Motor is permanently lubricated. Do not oil or disassemble motor.
Blower and duct connector
in straight-through discharge
position. (Factory-shipped)
Blower and duct connector
in right-angle discharge
position.
WIRING OPTIONS
Wiring plate mounts to side or top of housing.
WIRING PLATE
POSITION
Mounting brackets in
factory-shipped position.
(Outlet parallel to joists.)
(New construction)
Mounting brackets flipped
over and mounted to outlet
sides of housing.
(Outlet parallel to joists.)
(Existing construction)
Mounting brackets mounted
to outlet sides of housing.
(Outlet perpendicular to joists.)
(New construction)
Mounting brackets flipped
over to give approx. 1”
more clearance.
(Outlet parallel to joists.)
(New construction)
Mounting brackets mounted
to top of sides of housing.
(Outlet parallel to joists.)
(New or existing construction)
Mounting brackets flipped
over and mounted to top
sides of housing.
(Outlet parallel to joists.)
(New or existing construction)
¼-20 hex nuts secure mounting brackets to housing. Loosen
and re-tighten or remove and replace nuts as necessary for
desired mounting bracket position. DUCT CONNECTOR DUCT CONNECTOR
BLOWER BLOWER
Change
blower &
duct connector
positions for
right angle
discharge.
ROOF CAP
ROUND
DUCT*
HORIZONTAL POWER
CABLE CONNECTION
VERTICAL
POWER
CABLE
CONNECTION
448 S. Main Street
Verona, Wisconsin 53593
KEY NO. PART NO. DESCRIPTION
1 97014735 Housing Assembly
(VCDD010I& VCDD015I)
97014736 Housing Assembly
(VCDD020I, VCDD025I& VCDD030I)
2 97014728 Mounting Bracket (2 req.)
3 97014760 Damper Assembly (6” dia.)
97014761 Damper Assembly (8” dia.)
4 99390098 Duct Connector (6” dia.)
99390099 Duct Connector (8” dia.)
5 99150415 Screw, 8-18” x ¼ (12 req.)*
6 98005513 Wire Box Cover
7 99400035 Strain Relief Bushing
8 98005512 Wiring Plate
9 99150471 Ground Screw, 10-32 x ½ (2 req.)
10 97014774 Scroll Assembly
(VCDD010I& VCDD015I)
97014775 Scroll Assembly
(VCDD020I, VCDD025I& VCDD030I)
11 98009399 Inlet Ring
12 99110805 Blower Wheel
13 99080481 Motor (VCDD010I)
99080482 Motor (VCDD015I)
99080483 Motor (VCDD020I)
99080484 Motor (VCDD025I)
99080485 Motor (VCDD030I)
14 99260558 Lock Nut, 8-32 (4 req.)*
15 99250959 Washer (4 req.)*
16 99100491 Grommet (4 req.)
Blower Assembly, Complete
(Includes Key Nos. 5 & 10-16)
97014800 (VCDD010I)
97014801 (VCDD015I)
97014802 (VCDD020I)
97014803 (VCDD025I)
97014804 (VCDD030I)
17 99260477 Nut, ¼-20 (6 req.)*
18 97006039 Wire Harness
19 98009417 Access Panel
20 99420470 Cover Nut (2 req.)
21 99150472 Cover Mounting Screw (2 req.)
22 99150591 Screw, 10-16 x 7/8 (4 req.)*
Order replacement parts by PART NO. - not by KEY NO.
* Standard hardware - may be purchased locally.
ASX-11238
MODELS • VCDD010I• VCDD015I
VCDD020I• VCDD025I• VCDD030I
Page 4
SERVICE PARTS SERVICE PARTS
BLOWER
ASSEMBLY

This manual suits for next models

5

Other Express Fan manuals

Express VMBL Series Assembly instructions

Express

Express VMBL Series Assembly instructions

Express VCDD0901 User manual

Express

Express VCDD0901 User manual

Popular Fan manuals by other brands

Keystone KSTFA12AAG instruction manual

Keystone

Keystone KSTFA12AAG instruction manual

Monte Carlo Fan Company 5AHR60 Series owner's manual

Monte Carlo Fan Company

Monte Carlo Fan Company 5AHR60 Series owner's manual

DVS G3 Operating guidelines

DVS

DVS G3 Operating guidelines

Craftmade KAT72ESP9 installation guide

Craftmade

Craftmade KAT72ESP9 installation guide

Monte Carlo Fan Company 4TK52 Series Owner's guide and installation manual

Monte Carlo Fan Company

Monte Carlo Fan Company 4TK52 Series Owner's guide and installation manual

Monte Carlo Fan Company 8EEDR60 D Series Owner's guide and installation manual

Monte Carlo Fan Company

Monte Carlo Fan Company 8EEDR60 D Series Owner's guide and installation manual

Hunter 42859-01 Owner's guide and installation manual

Hunter

Hunter 42859-01 Owner's guide and installation manual

Hunter 21705 Manual de Installatión y Operatión

Hunter

Hunter 21705 Manual de Installatión y Operatión

Impecca FANFAIR FWF-1600 user guide

Impecca

Impecca FANFAIR FWF-1600 user guide

AirTech Air+ PIV Installation & commissioning instructions

AirTech

AirTech Air+ PIV Installation & commissioning instructions

Parrot Uncle F3513 Installation & operating instructions

Parrot Uncle

Parrot Uncle F3513 Installation & operating instructions

Hunter 20578 owner's manual

Hunter

Hunter 20578 owner's manual

OSTBERG IRB 125 B1 EC Directions for use

OSTBERG

OSTBERG IRB 125 B1 EC Directions for use

Monte Carlo Fan Company 5HVO44 Series Owner's guide and installation manual

Monte Carlo Fan Company

Monte Carlo Fan Company 5HVO44 Series Owner's guide and installation manual

Monte Carlo Fan Company Mini 4MC20BS Owner's guide and installation manual

Monte Carlo Fan Company

Monte Carlo Fan Company Mini 4MC20BS Owner's guide and installation manual

Trox Technik CAK installation manual

Trox Technik

Trox Technik CAK installation manual

emerio FN-114309.4 instruction manual

emerio

emerio FN-114309.4 instruction manual

iGenix IGFD4009W user manual

iGenix

iGenix IGFD4009W user manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.