RC200-EU-EN-V1.4-3/114
Operating Instructions
WARNING: Risk of electrocution. High-voltage circuits, both AC and DC, are very
dangerous and should be measured with great car e.
1. If “OL” appears in the display duri ng a measurement, the value exceeds the range you
have selected. Change to a higher range.
2. The meter will automatically recognize if the voltage test leads or tweezers adaptor is
inserted.
3. The meter will turn on with autoranging “AUTO” selected. In this mode, the unit will
automatically select the prope r range to measure the device under t est. Press the
“RANGE” button to go to manual ( “MANU”) ranging. Continue pressing the button unt il
the range desired is selected. Press and hold the RANGE button f or two seconds to
return to autoranging.
4. On some low AC and DC voltage ranges, with the test leads not connected to a device,
the display m ay show a random, changing readi ng. This is normal and is caused by the
high-input sensitivity. The reading will stabilize and give a proper measurement when
connected to a load.
Test Lead AC/DC Voltage Measurements
1. Insert the voltage adaptor into the meter observing the polarity indicators.
2. Press the MODE button for 2 seconds until the meter beeps. “V ” will be displayed on the
LCD
3. Press the MODE button to select either AC or DC voltage.
4. Touch the black test probe tip to the negative side of the circuit.
Touch the red test probe tip to th e positive side of the circuit.
5. Read the voltage in the display.
Note: The “
“ DANGER symbol will appear in the display whenever the measured voltage
exceeds 30V
WARNING: To a void electric shock, disconnec t power to the unit under test and
discharge all capacitors before taking any capacitance or resistance measurements.
Remove the batteries and unplug line cords.
Tweezer Resistance, Capacitance, Continuity and Diode Measurements.
1. Insert the tweezers adaptor into the meter observing the polarit y indicators.
2. Press the MODE button for 2 seconds until the meter beeps. The meter turns on in the
SCAN mode and “- - - -“ on the di splay.
3. Insert a component into the tweezers contacts. In the SCAN mode, the meter
automatically sel ects the proper range and units (Capacitance or Resistance).
4. Read the measurement results in the display.
5. Press the MODE button to exit the SCAN mode and begin resistance measurements.
The “Ω” icon will appear on the display.
6. Press the MODE button for continuity measureme nts. The
icon will appear on the
display. The meter will beep if the resistance is less than the continuity threshold.
7. Press the MODE button for diode measurements. The
icon will appear on the
display. A go od diode will read “OL” in one direction and a lo w voltage in the opposite
direction.
8. Press the MODE button for capacitance measurem ents .The “F” icon will appear on the
display. It can take several minutes for the re ading to stabilize at the final value for large
value capacitors.
9. Press the MODE button again to r eturn to the SCAN mode.