SAFETY INFORMATION
PROTECTION FROM ELECTRIC SHOCK
Warning! This product is for professional use only. It is not for household or residential use.
This product presents risks of lethal or severe injury due to fire and heat, electric shock, ultraviolet
radiation, lamp explosion, and falls. Read this manual before powering or installing the fixture, follow the
safety precautions listed below and observe all warnings in this manual and printed on the fixture. If you
have any question about how to use this fixture safely, please contact your Entar dealer.
Warning! Always disconnect from mains supply before replacing the lamp.
Disconnect the fixture from AC power before removing or installing the lamp, fuse, or any part, and when
not in use.
Always ground (earth) the fixture electrically.
Use only a source of AC power that complies with local building and electrical codes and has both
overload and ground-fault protection.
Do not expose the fixture in rain and moisture.
Refer any service operation not described in this manual to a qualified technician.
PROTECTION FROM UV RADIATION AND LMP EXPLOSION
Never operate the fixture with missing or damaged lenses and/or covers.
When replacing the lamp, allow the fixture to cool for at least 15 minutes before opening the fixture of
removing the lamp. Protect your hands and eyes with gloves and safety glasses.
Do not stare directly into the light. Never look at an exposed lamp while it is lit.
Replace the lamp if it becomes defective or worn out, or before usage exceeds the maximum service life.
PROTECTION FROM BURNS AND FIRE
Danger! Intense heat. Avoid contact by persons and materials.
The exterior of the fixture can get very hot – up to 120
°
C. Allow the fixture to cool for at least 45
minutes before handling.
Prolonged exposure to unshielded lamp can cause eye and skin burns.
Never attempt to bypass the thermostatic switch or fuses. Always replace defective fuses with ones of
the specified type and rating.
Keep all combustible materials (for example fabric, wood, paper) at least 1 meter away from the fixture.
Keep flammable materials well away from the fixture.
Do not illuminate surfaces within 3 meters (10 feet) of the fixture.
Provide a minimum clearance of 0.1 meters around fans and air vents.
Never place filters or other materials over the lens.

Extra575usermanual Entar Professional Limited 3
INTRODUCTION
MAIN FEATURES
540°pan and 270° tilt at 8/16 bit
DMX channels: 13
Lamp: Discharge lamp 575W, double ended (optional)
Power consumption: 660W
Dimmer: Smooth mechanical dimming 0-100%
Strobe: 1~10 f.p.s.
Prism: Rotating in both directions, three faces prism
Color: 8 plus open white with rainbow effect
Rotating gobo: 6 plus open white
Focus: Motorized
Speed: pan and tilt speed adjustment
Pan and tilt position correction
SETUP
UNPACKING
The Extra 575 comes with:
User manual
Power cable
2x XLR connectors
Lamp and clamps are optional (Please contact your dealer for more information)
AC POWER
Warning! For protection from electric shock, the fixture must be grounded (earthed). The power supply
shall have overload and ground-fault protection.
RIGGING OR MOUNTING THE EXTRA 575
Warning! Attach an approved safety cable to the attachment point provided in the base. Never use the
carrying handles for secondary attachment. Always use an approved safety cable.
CONNECTING THE SERIAL DATA LINK
The Extra 575 has locking 3-pin data input and output sockets that are wired for use with DMX devices
with pin 1 to shield, pin 2 to cold(-) and pin 3 to hot(+).
1. Connect the controller’s output to the fixture’s data input.
2. Connect the output of the fixture closest to the controller to the input of the next fixture. If connecting
a fixture with pin 3 hot to a fixture with pin 3 cold, use a phase-reversing adaptor.
3. To terminate the link, insert a male 120ΩXLR termination plug in the output of the last fixture.

Extra575usermanual Entar Professional Limited 4
TIPS FOR BUILDING A SERIAL LINK
zUse shielded twisted-pair cable designed for RS-485 devices: standard microphone cable cannot
transmit DMX data reliably over long runs. For links up to 300 meters (1000 ft.) long, you can use
24 AWG, low capacitance, 85-150 ohm characteristic impedance, shielded cable with 1 or more
twisted pairs. For runs up to 500 meters (1640 ft.) use 22 AWG cable. Use an amplifier if the serial
link exceeds 500 meters.
zNever use a “Y” connector to split the link. To split the serial link into branches use a splitter.
zDo not overload the link. Up to 32 devices may be connected on a serial link.
zTerminate the link by installing a termination plug in the output socket of the last fixture on the link.
The termination plug, which is simply a male XLR connector with a 120 ohm, 0.25 watt resistor
soldered between pins 2 and 3, “soaks up” the control signal so it does not reflect back down the
link and cause interference. If a splitter is used, terminate each branch of the link.
CONTROL PANEL
MENU NAVIGATION
The DMX address is displayed after the fixture resets. To enter the menu, press [mode]. Use the [up] and
[down] keys to select an option.
SETTING THE DMX MODE
1. Apply power to the Extra 575. Press [mode] to enter the Addr mode.
2. Select a DMX starting address by using the [up] and [down] keys.
3. Store the DMX starting address by pressing the [mode].
MOVEMENT
The Extra 575 provides 2 menus with options for optimizing movement to suit different applications.
(PAN->YES) allows you to reverse pan movement.
(Tilt->YES) allows you to reverse tilt movement.
RESET
The Extra 575 can be reset without switching off the power supply (RSET).
1. Press [mode] to enter the (rSEt) mode.
2. Press [up] or [down] key to reset the fixture.
OPERATING MODES
The Extra 575 can run in 3 modes: DMX, sound activation and auto. The fixtures can run in master/slave
mode with sound activation.
To activate sound trigger, press [mode] to enter (RUN), then press [up] or [down] key to select (PRG0).
To run the built-in sequences, press [mode] to enter (RUN), then press [up] or [down] key to select
(PRG1).
To set a fixture run as a slave unit, press [mode] to enter (RUN), then press [up] or [down] key to select
(FOLL).

Extra575usermanual Entar Professional Limited 5
DMX PROTOCOL
DMX channel Value Function
1 0-255 Pan
(127 = neutral)
2 0-255 Tilt
(127 = neutral)
3 0-255 Pan 16 bit
4 0-255 Tilt 16 bit
5
0-255
Pan/Tilt speed
Fast → slow
6
0-7
8-230
231-239
240-255
Shutter, strobe, reset
Shutter closed
Strobe, fast →slow
Keep 4 seconds for reset the fixture
Shutter open
7
0-255
Dimming
Dark Æbright
8
0-13
14-28
29-41
42-55
56-69
70-88
89-97
98-111
112-127
128-191
192-255
Color
White
Blue
Purple
Pink
Red
Green
Yellow
L. blue
Orange
Continuous rotation
CCW, slow →fast
CW, slow →fast
9
0-17
18-35
36-53
54-71
72-89
90-107
108-127
128-191
192-255
Gobo selection
Open gobo
Gobo 1
Gobo 2
Gobo 3
Gobo 4
Gobo 5
Gobo 6
Continuous scroll
CCW, slow →fast
CW, slow →fast
10
0-16
17-136
137-255
Gobo rotation
No rotation
CCW, slow →fast
CW, slow →fast

Extra575usermanual Entar Professional Limited 6
11
0-127
128-255
Prism
Prism off
Prism on
12
0-8
9-119
120-231
232-255
Prism rotate
Still
CCW, slow →fast
CW, slow →fast
Macro
13
0-255
Focus
Infinity Æclose
Table of contents
Popular Speakers manuals by other brands

Kenwood
Kenwood KFC-1652MRW/B installation instructions

Philips
Philips SPA2360/17 user manual

Bowers & Wilkins
Bowers & Wilkins CM7 owner's manual

HMDX
HMDX AMP User guide and warranty information

Troldekt
Troldekt Troldekt installation instructions

Audio Pro
Audio Pro Image Series Image 44 Mounting instructions