Command ASCII Command Response Additional Description
Video Mute
Mute output video X@*1B VmtX@*1]Mute the video on output X@.
Mute video on all outputs 1B Vmt1]Mute the video on all outputs.
Mute video and sync 2B Vmt2]Mute the video and sync on all outputs.
Unmute video and sync 0B Vmt0]Unmute the video on all outputs.
View output mute status B VmtX4@1•X4@2•X4@3]View mute status X4@ for outputs 1, 2, and loop (3).
Audio Configuration
Set audio input format EIX!*X5*AFMT}AfmtIX!*X5*]Set the audio format of input X! to X5*.
View audio input format EIX!AFMT}X5*]View the audio format of input X!.
Front Panel Lockout (Executive Modes)
Enable lock mode 1 1X Exe1]Lock all front panel controls.
Enable lock mode 2 2X Exe2]Lock the front panel except for input selection, logo
conguration, and volume adjustment.
Enable lock mode 3 3X Exe3]Lock the front panel except for input selection and logos.
Enable lock mode 4 4X Exe4]Lock the front panel except for volume adjustment.
Disable executive modes 0X Exe0]Allow all front panel adjustments and selections.
IP Settings
Set switcher IP address EX8&CI}Ipi•X8&] Specify a new switcher IP address.
Set switcher DHCP mode EX( DH}Idh X1)] Enable or disable DHCP (0= default).
Set subnet mask EX8*CS}Ips•X8*] Specify a new subnet mask.
Set gateway IP address EX8(CG}Ipg•X8(] Specify a new gateway IP address.
Reboot network E2BOOT}Boot2]Restart network connection after IP or DHCP changes.
NOTE: IP settings do not take effect until the E2BOOT}command is executed.
Twisted Pair Protocol
Set input TP type EIX!*X6&HDBT}HdbtIX!*X6&] Set the DTP2/XTP type for input X! to X6&.
View input TP type EIX!HDBT}X6&] View the current DTP2/XTP type for input X!.
Set output TP type EO2*X6&HDBT}HdbtO 2*X6&] Set the TP type for input X! to X6&.
View output TP type EO2HDBT}X6&] View the DTP2/XTP/HDBT setting X6& on output 2.
DTP Remote Power Parameters
Set input remote power EIX!*X6^RPWR}RpwrIX!*X6^] Set remote power on input X! to X6^.
View input remote power EIX!RPWR}X6^] View remote power setting on input X!.
Set output 2 remote power EO2*X6^RPWR}RpwrO 2*X6^] Set remote power on output 2 to X6^.
View output 2 remote power EOX@RPWR}X6^] View remote power setting on output .
KEY:
X! = Input selection Inputs 1 through 8. For the Twisted Pair Protocol commands, X! = Inputs 7 and 8 only.
X@ = Output selection 1= Output 1 (HDMI/DVI), 2= Output 2 (DTP2/XTP/HDBT)
X1) =Enable or disable 0= Off or disabled, 1= on or enabled
X4@ =Video mute status 0= Unmuted, 1= muted
X5* =Audio input type 0= None (input muted), 1= Analog aux line (5-pole captive screw), 2= LPCM-2Ch, 3= Multi-Ch,
4= LPCM-2Ch Auto (AUX) (default), 5= Multi-Ch Auto (AUX)
X6^ =DTP remote power 0= Off (No remote power, default), 1= DTP 12 VDC, 2= DTP 48 VDC
X6& =TP format 0= DTP2 format (default), 1= XTP, 2= HDBaseT format (supported on output only)
X8& =IP address Format nnn.nnn.nnn.nnn, 192.168.254.254 = default
X8* =Subnet mask Format nnn.nnn.nnn.nnn, 255.255.255.0 = default
X8( =Gateway address Format nnn.nnn.nnn.nnn, 0.0.0.0 = default