3. Fit all pathways side by side through opening.
4. Slide wall plate over pathways. With the ends of all pathways evenly aligned, set the wall plate to the correct wall thickness
Pre position and fasten wall plate to one side of pathway (fig. 3) roughly centering pathway within barrier.
5. Carefully tighten all set screws (See Fig 4).
6. Slide plate with mounted pathways tight against wall surface.
7. Fasten wall plate to wall as required (See Table A), (Fig 5).
8. Moving to the opposite side of the wall, install remaining plate making sure to tighten all set screws. Fasten plate to wall if required.
GENERAL - READ COMPLETELY BEFORE INSTALLING
This product allows for several optional installation methods.
The pathway (device) consists of an enclosed heavy
gauge galvanized steel channel with a detachable lid.
Pathways (devices) are ordered separately. Gang plates
are designed to accommodate up to four or seven device
installations. Component requirements will vary according
to the method of installation chosen.
NOTE: Wall installations require this device to be installed with
the top (lid) facing upward. The lid may be identified by the
EZ-Path®logo stamped onto the face of the steel lid. Gang plates
are asymmetrical with the stencil marking the top.
INSTALLATION SHEET
Four & Seven Gang Mounting Plates
EZP433W, EZP433GK, EZP733W, EZDP733GK
Page 1 of 2 Installation Sheet •EZ-PATH® Four & Seven Ganga Mounting Plates ZIS1005 - 3345
ZIS1005 - 3345
TABLE A: Slot Size & Capacity
Stud spacing 16” (406 mm) 24” (610 mm)
Mounting plate
part number EZP433W EZP733W
Capacity
(Qty. of devices) (4) EZD33FWS (7) EZD33FWS
Slot size 12-1/8” x 3-1/8”
(308 mm x 80 mm)
21-1/8” x 3-1/8”
(537 mm x 80 mm)
Fastener Requirements
Gypsum board 2” (51 mm) L Type S screws 2” (51 mm) L Type S screws
Fasten to studs (OPTIONAL) (REQUIRED)
Masonry
1” X 1/8”masonry screws
(25 mm x 3 mm)
(OPTIONAL)
1” X 1/8”masonry screws
(25 mm x 3 mm)
(OPTIONAL)
Option 1 – Installation in Finished Walls
1. Determine a suitable location for installation. Plates are
designed to allow either 4 pathways (studs 16” , 406 mm OC)
or 7 pathways (studs 24”, 610 mm OC) to be installed hori-
zontally in a row. Installation requires an opening to be cut or
formedcompletelythroughthewall(bothsides)perthedimen-
sions listed in Table A. In hollow walls, care must be exer-
cised to assure that slots on both sides are properly aligned
(See Fig. 1).
2. Install gasket tape to the flat side of both plates (See Fig 2).
Apply by aligning tape to the inside edge of the framed
opening. Remove release liner and adhere tape.
Option 2 – Installing Devices Prior to Wallboard (New Wall Construction)
1. Invert gang plates such that flanges project into stud cavity and fasten directly to studs using four 5/8” (16 mm) Type S
screws on each side of stud cavity (See Fig. 6).
2. Install devices and tighten set screws provided with device using Allen wrench supplied (See Fig. 3 & 4).
3. Complete wall construction as required by design. Opening in wallboard facing shall be cut so that clearance between
devices and wallboard does not exceed 1/8” (3 mm).
4. Resulting gap shall be filled with joint compound or SpecSeal®brand firestop sealant at the option of the installer (See Fig. 7 & 8).
Fig. 1 Fig. 2 Fig. 3
Fig. 5
Fig. 4
Fig. 7 Fig. 8
Fig. 6
Page 2 of 2 Installation Sheet •EZ-PATH® Four & Seven Ganga Mounting Plates ZIS1005 - 3345
Option 3 – Large Block Outs in Concrete Floors and Walls
1. Form or cut opening to allow gang plate to overlap a minimum 1” (25 mm) on both sides. Fasten
gang plates to concrete using 1” long by 1/8” (25 mm x 3 mm) diameter steel masonry screws
(See Fig. 9).
2. Center desired number of devices within floor or wall assembly and tighten set screws provided
with device using Allen wrench supplied.
3. Install SpecSeal® Firestop Mortar, mortar or hydraulic cement into void between periphery of
opening and device(s) to a minimum depth of 4-1/2” (114 mm) in floors and 6” (152 mm) in walls.
INSTALLING or PULLING CABLES
A resilient liner provides an adjustable seal within the pathway device. Liner must be protected from
damage while adding or removing cables. Wrap cable ends with a suitable low friction tape before
inserting into the pathway. Where cable lubricants are used, low solids, water-based products are
recommended. This device is designed to be fully functional at all cable loadings from completely
empty to visually filled, and cables should easily slide through the pathway using minimal effort. IF
RESISTANCE IS ENCOUNTERED, DO NOT FORCE CABLES OR CABLE BUNDLES THROUGH
THE PATHWAY. DAMAGE MAY RESULT. Upper curved liner may be depressed when inserting
cables, if necessary, using a flat, smooth implement and then removing it after cables are installed.
The rectangular shape of the loading area coupled with gentle pressure exerted by resilient liners
will naturally distribute the cables at a relatively uniform height across the width of the device. The
use of a cable dressing/combing instrument to straighten and organize cables may help to maximize
usable space within the pathway device.
GROUNDING
At the option of the installer, this device may be grounded. After device(s) has been installed, insert
ground screws where indicated (See Fig. 10). For installations using single, double, or triple wall plates,
or optional positioning clamps, two ground screws are required and are included in these kits.
LABELING
Labels are provided with the device as well as wall plate kits. Larger orange colored label is intended
to be used to identify the device’s installer as well as to provide applicable UL System information.
Smaller secondary labels are included with double, triple, four and seven gang mounting plates
plates as an optional method for identifying or marking cable types, uses, or trades. Two sets of
labels are provided for marking both sides of wall or floor.
Fig. 10
Fig. 9
MAINTENANCE
No maintenance of the device is normally required. Interior of device should be inspected before
and after any modifications to cable bundle. If any damage to intumescent pads lining top and
bottom of the device is found, contact the factory to determine if replacement is required.
Important Notice: All statements, technical information, and recommendations
contained herein are based upon testing believed to be reliable, but the accuracy
and completeness thereof is not guaranteed.
WARRANTY: Specified Technologies Inc. manufactures its goods in a manner to
be free of defects. Should any defect occur in its goods (within one year), Specified
Technologies Inc., upon prompt notification, will at its option, exchange or repair
the goods or refund the purchase price.
Limitations and Exclusions: THIS WARRANTY IS IN LIEU OF ALL OTHER
REPRESENTATIONS EXPRESSED OR IMPLIED (INCLUDING THE IMPLIED
WARRANTIES OF MERCHANTABILITY OR FITNESS FOR USE) AND
UNDER NO CIRCUMSTANCES SHALL SPECIFIED TECHNOLOGIES INC. BE
RESPONSIBLE FOR ANY INCIDENTAL OR CONSEQUENTIAL PROPERTY
DAMAGE OR LOSSES. PRIOR TO USE, THE USER SHALL DETERMINE THE
SUITABILITY OF THE PRODUCT FOR ITS INTENDED USE, AND THE USER
ASSUMES ALL RISKS AND LIABILITY FOR SUBSEQUENT USE. No statement
or recommendation not contained herein shall have any force or effect unless in an
agreement signed by officers of seller and manufacturer.
MADE IN USA • PRINTED IN USA – COPYRIGHT © 2015 SPECIFIED
TECHNOLOGIES INC.
Somerville, NJ 08876 USA
Phone: (800) 992-1180 • www.stifirestop.com

This manual suits for next models

4

Popular Rack & Stand manuals by other brands

interion ONTOP 192-42106 quick start guide

interion

interion ONTOP 192-42106 quick start guide

Seneca AV SD11 user manual

Seneca AV

Seneca AV SD11 user manual

GABOR ACCUGEAR UPMP-1000 user manual

GABOR

GABOR ACCUGEAR UPMP-1000 user manual

Konig & Meyer 18878 manual

Konig & Meyer

Konig & Meyer 18878 manual

UPC 3536 Assembly instructions

UPC

UPC 3536 Assembly instructions

Savant Shade Double Drive Quick reference guide

Savant

Savant Shade Double Drive Quick reference guide

Ledra Brands BRUCK Eco Track installation instructions

Ledra Brands

Ledra Brands BRUCK Eco Track installation instructions

Mounting Dream MD2268-XL Installation instruction

Mounting Dream

Mounting Dream MD2268-XL Installation instruction

Nibe DEW 41 Installer manual

Nibe

Nibe DEW 41 Installer manual

Altelix NS241610-DIN installation guide

Altelix

Altelix NS241610-DIN installation guide

CHIEF FSA-1015 installation instructions

CHIEF

CHIEF FSA-1015 installation instructions

Rose electronics XTREME S.P.R. III owner's manual

Rose electronics

Rose electronics XTREME S.P.R. III owner's manual

Crestron RMK-17L installation guide

Crestron

Crestron RMK-17L installation guide

New Star Computer Products NOTEBOOK-D300 instruction manual

New Star Computer Products

New Star Computer Products NOTEBOOK-D300 instruction manual

peerless-AV LCD Screens Installation and assembly

peerless-AV

peerless-AV LCD Screens Installation and assembly

Mo-vis Q2M User & installation manual

Mo-vis

Mo-vis Q2M User & installation manual

Ergotron Neo-Flex Wall Mount Lift Assembly instructions

Ergotron

Ergotron Neo-Flex Wall Mount Lift Assembly instructions

Vac-Rac QUAD RAC instructions

Vac-Rac

Vac-Rac QUAD RAC instructions

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.