FAG FLUO DX preliminary User Manual
Contents
The FLUO DX invisible ink colorimeter .................................................................................................... 1
Safety Instructions................................................................................................................................... 2
DECLARATION OF CONFORMITY ......................................................................................................... 2
This Manual............................................................................................................................................. 3
HARDWARE RESET of the DEVICE............................................................................................................ 3
Device Status information....................................................................................................................... 4
Positioning LED........................................................................................................................................ 4
Start Display............................................................................................................................................. 5
Measure References................................................................................................................................ 5
Fluorescence Intensity Reference (F256 or F365)............................................................................... 5
Phosphorescence Reference............................................................................................................... 6
Measure Intensity.................................................................................................................................... 6
Measure Fluorescent Intensity............................................................................................................ 6
Measure Phosphorescence Intensity .................................................................................................. 8
MLab Laboratory function................................................................................................................... 9
Fluorescent MLab function.............................................................................................................. 9
M Lab Phosphorescence.................................................................................................................... 10
MSpez function...................................................................................................................................... 11
The FLUO DX invisible ink colorimeter
The FLUO DX Invisible ink colorimeter is the ideal Device to control the use of invisible and
phosphorescent inks in the press room. The FLUO DX is equipped with two UV LEDs, at 365nm and
256nm and measures the Fluorescent Intensity, the Colorimetric parameters XYZ, xy, Lab, LCh and
the Phosphorescent characteristics of an ink.
Important: This manual describes the current version of the FLUO DX hardware and software. Future
enhancements or modifications are reserved.