FAMILY INADA HCP-S878D User manual

HCP-S878D
● Please read this Operating Manual before use.
●
Keep this Operating Manual nearby so that you can refer to it anytime.
●
This product is designed for home use.
● 使用前請詳細閱讀本操作手冊。
● 請妥善保管本操作手冊於方便查找之處,以備不時之需。
● 本機僅限於家庭使用。
● 使用前请阅读本使用说明书。
● 请将本使用说明书妥善保管在便于使用者查找的地方,以备不时之需。
● 本机仅限于家用。
Thank you for purchasing the INADA CHAIR.
You can enjoy various types of massage for relieving or soothing fatigue.
We hope the INADA CHAIR will be a valued partner in your daily health
preservation for many years to come.
感謝您選購 INADA CHAIR 按摩椅。
本產品能緩解並改善您的疲勞,帶給您多種按摩享受。願本產品成為
您永遠的健康良伴。
感谢您选购 INADA CHAIR 按摩椅。
本产品能缓解并改善您的疲劳,带给您多种按摩享受。愿本产品成为
您永远的健康良伴。
中文
操作手冊
另附保固卡
Operating Manual
Warranty card provided separately
使用说明书
另附保修卡
繁體中文
ENGLISH


CONTENTS
■SAFETY PRECAUTIONS ..................1
■MAIN FEATURES.............................4
■COMPONENTS & DESCRIPTION ....5
■BEFORE USE....................................7
■POSITION ADJUSTMENT .............12
■AFTER USE ....................................14
■CARE AND STORAGE....................15
■PROGRAMS & SELECTION ...........16
■PRESET PROGRAMS.....................17
■MANUAL SELECTION ...................19
■TROUBLESHOOTING....................23
■
REGULAR MAINTENANCE FOR SAFETY
...24
■FAQ................................................25
■AFTER SALES SERVICE .................27
■SPECIFICATIONS ..........................28
Thank you for purchasing the INADA CHAIR.
You can enjoy various types of massage for relieving or soothing fatigue.
We hope the INADA CHAIR will be a valued partner in your daily health
preservation for many years to come.
●Please read this Operating Manual before use.
●Keep this Operating Manual nearby so that you can refer to it anytime.
●This product is designed for home use.
Operating Manual
Warranty card provided separately
ENGLISH
HCP-S878D

[SAFETY PRECAUTIONS]
1
SAFETY PRECAUTIONS
Types of Indications
Warning This action could result in serious injury or death.
Caution This action could result in personal injury or damage to property.
Types of Symbols and Description
Prohibited
Prohibited.
Do not
disassemble
Do not disassemble.
No wet hands
Do not handle with wet hands.
Do not wet
Do not use in a location where the chair
may become wet.
Prohibited
Do not use in a bathroom.
Required Action
Required action.
Unplug
the chair
Unplug the power plug from the wall
outlet.
Remember to keep this Operating Manual in an easily accessible place.
Safety Precautions: Installation
Caution
Prohibited
●Do not install the chair in an area of high humidity,
such as a bathroom or sauna.
→Could result in electric shock or damage to the chair.
Prohibited
●Never connect the ground wire to gas pipes, water pipes,
telephone lines, or lightning rods.
Required Action
●Install on a at, level surface only.
→Chair could tip over accidentally if placed on an uneven
surface, resulting in an accident.
Safety Precautions: Installation
Warning
Electrical
grounding
●Space Requirements
This product must be grounded. If it should malfunction or breakdown, grounding provides a path of
least resistance for electric current in order to reduce the risk of electric shock. This product is equipped
with a cord having an equipment-grounding conductor and a grounding plug.
The plug must be plugged into an appropriate outlet that is properly installed and grounded in
accordance with all local codes and ordinances.
•
Improper connection of the equipment-grounding conductor can result in the risk of electric
shock. Check with a qualied electrician or serviceman if you are in doubt as to whether the
product is properly grounded. Do not modify the plug provided with the product if it will not
t the outlet; have a proper outlet installed by a qualied electrician. This product uses on
a normal Alternating Current(AC) circuit and has a grounding plug that looks like the plug
illustrated in the gure to the right. Make sure that the product is connected to an outlet
having the same conguration as the plug. No adapter should be used with this product.
Required Action
●Always unplug this appliance from the electrical outlet immediately after using and before cleaning.
Caution
Prohibited
●Do not operate under blanket or pillow. Excessive heating can occur and cause re, electric shock, or injury to persons.
●Use this appliance only for its intended use as described in this Operating Manual. Do not use attachments not recommended by
the manufacturer.
●Never operate this appliance if it has a damaged cord or plug, if it is not working properly, if it has been dropped or damaged, or
dropped into water. Return the appliance to a service center for examination and repair.
●Do not carry this appliance by supply cord or use cord as a handle.
●Never operate the appliance with the air openings blocked. Keep the air openings free of lint, hair, and the like.
●Never drop or insert any object into any opening.
●Do not use outdoors.
●Do not operate where aerosol (spray) products are being used or where oxygen is being administered.
●Children shall not play with the appliance.
→May result in accident or injury.
Required Action
●
An appliance should never be left unattended when plugged in. Unplug from outlet when not in use, and before putting on or taking oparts.
●Close supervision is necessary when this appliance is used by, on, or near children, invalids, or disabled persons.
●Keep the cord away from heated surfaces.
●To disconnect, turn all controls to the oposition, then remove plug from outlet.
●Keep children away from extended foot support (or other similar parts).
●Connect this appliance to a properly grounded outlet only. See Grounding Instructions.
●This appliance can be used by children aged from 8 years and above and persons with reduced physical, sensory or mental
capability or lack of experience and knowledge if they have been given supervision or instruction concerning use of the
appliance in a safe way and understand the hazards involved.
→May result in accident or injury.

[SAFETY PRECAUTIONS]
2
Safety Precautions: Before Use
Warning
Prohibited
●The following persons must not use this massage chair:
◎Persons who have been instructed by a doctor to avoid massage therapy. Ex. Thrombosis, severe aneurism, acute varicosity, or dermatitis and/or
skin infection including inammation of the typodermis. ◎Persons with suspected acute neck sprain (whiplash injury)
●Do not use the chair with any power supply other than those shown in the table on the right.
→May result in re or electric shock.
●Do not use with any type of transformer device.
→May result in damage to the chair or electric shock.
●Do not use the chair, if the power cord or plug is damaged, or if the wall outlet connection
is loose.
→May result in electric shock, short circuit, or combustion.
●Before each use, check for holes or tears in the chair covering. Also, check the other parts for tearing. Unplug the chair and
contact the “Repair Service Center“ (see back page) for assistance. Never use the chair with the chair covering removed or with
holes or tears in the covering, because doing so is extremely dangerous.
→Using the chair with holes or tears in the covering could result in injury or electric shock.
Required Action
●Persons with any of the following conditions should seek medical advice before using the chair:
◎Serious heart conditions ◎Sensory impairment caused by serious peripheral circulatory disorders due to diabetes and other diseases
◎Osteoporosis, spinal fractures, acute pain and/or symptoms thereof ◎Persons being treated for personal injuries
◎High fever (38°C (100°F ) or higher) Ex. Strong acute inammation illness caused by fatigue, chills, blood pressure uctuation, or asthenia
◎Persons in the early stages of pregnancy, or immediately after giving birth. ◎Persons who have electronic medical device(s) easily susceptible to
electromagnetic interference, e.g. pacemaker
◎Abnormal or curved spine ◎Persons planning to use the chair for treatment or for rehabilitation purposes ◎Persons with malignant tumor(s)
◎Persons under bed rest orders ◎Persons with acute gastro-intestinal complaints or ailments such as gastritis, enteritis, or hepatitis
◎Persons under a doctor's care, or those experiencing unusual physical discomfort ◎Joint dysfunction due to rheumatism, gout, or other
diseases ◎Persons with symptoms such as qualm, dizziness, or tinnitus ◎Inammation due to sprains, muscle strain, or other injuries
◎Persons with thecitis or suspected thecitis ◎Persons with thermoanesthesia
●Elderly people and persons with weak bones should seek medical advice before using the chair, even if they do not have a
specic disease.
●If your condition does not improve after use, consult a doctor or specialist.
Caution
Prohibited
●Do not use the chair in any way not prescribed by the Operating Manual. Do not use the chair together with any other therapeutic
device or with an electric blanket.
→May result in injury or have a negative eect on health.
●Do not move the chair while someone is in it.
→Accident or injury may result if the chair tips over.
●Do not sit down on the chair with the leg rest raised.
→Any sudden impact on the leg rest could cause damage to the mechanism. Also, an accident or injury may result if the chair tips over.
●Do not use with anything other than the accessories supplied with this product.
Required Action
●Before plugging the power cord into the wall outlet, make sure that the power switch is set to OFF.
→May result in damage to the chair or electric shock.
●Make sure that the plugs on the power cord are inserted fully into the cord connector and the wall outlet.
→May result in electric shock, short circuit, or combustion.
●Before using the chair for the rst time, turn on all the switches in order as indicated in this Operating Manual to check that the
chair is operating properly.
●Before using, raise the reclining seat to its fully upright position. Then recline the seat back slowly to the most comfortable
position, remembering to start owith a lighter massage.
→Starting with a deep massage may hurt the user. Elderly people and persons with weak bones should be especially careful when selecting
massage intensity.
●For safety, sit down in the chair slowly without turning or twisting the body to ensure that the spinal rollers are placed at either
side of the spine.
●Do not sit, stand, or lean on the leg rest unless you are sitting in or getting up from the chair.
→Personal injury or damage to the chair may result if the chair tips over.
●If you use the chair after it has not been used for a long time, read this Operating Manual again thoroughly and check if the chair
operates properly.
Safety Precautions: During Use
Warning
Prohibited
●Do not wrap the power cord or the remote controller cord around your body, or place the chair on top of either cord. Do not
scratch, tear, treat, unduly twist, stretch or bend the power cord or the remote controller cord.
→The cords may be damaged, resulting in re or electric shock.
●Do not spill water and/or other liquids on the chair or remote controller.
→May result in electric shock, short circuit, or combustion.
●It is advisable to keep children and pets othe chair and away from the surrounding area (especially behind the reclining seat
back or under the seat or leg rest).
→Could result in accident or injury.
●
Do not use the chair while more than one person is sitting in it. In particular, do not use the chair while holding a small child (or baby).
→Could result in accident or injury.
●Do not use the chair while your body is wet, or with wet hands.
→Could result in electric shock or damage to the chair.
●Do not use the chair if the covering is torn. If it is, unplug the power cord from the wall outlet.
→Could result in an accident, injury or electric shock. For repairs, contact the “Repair Service Center“ (see back page) for assistance.
●Do not release hands suddenly while lifting the leg rest by hand.
Required Action
●Make sure no one, especially children or pets, is in the way when lowering or raising the reclining seat back. Be careful that
people or objects are not caught behind the seat back or under the leg rest.
Model number Power supply
HCP-S878D 220-240V

[SAFETY PRECAUTIONS]
3
SAFETY PRECAUTIONS
Safety Precautions: During Use
Caution
Prohibited
●Do not use the chair unclothed.
●Do not use the chair for purposes other than massage, or other than the ordinary uses of a chair.
→Could result in accident or injury.
●Do not use the chair to massage the head, chest, stomach, and/or joints (knees, elbows).
→May result in nausea or injury. Place a soft towel behind your neck if you want to avoid intense stimulation of the area.
●
Do not place your hands or feet into the roller tracks, into the space between the seat back and the seat or into the moving parts.
Do not sit wearing hard objects, such as hair accessories, or a necklace, watch, bracelet or ring.
→May result in personal injury.
●Do not place anything other than legs and feet on the leg rest.
→May result in personal injury.
●Do not operate the massage chair or leave it operating when there is no one in it.
→Could result in accident or injury.
Required Action
●
In an emergency, or if you nd any abnormal condition, push the EMERGENCY STOP button on the remote controller to stop operation immediately.
●
If you get acute pain or other unusual physical discomfort while using the chair, immediately discontinue the use of the chair and seek medical advice.
●If you feel the massage is too strong, reduce the stimulation according to this Operating Manual. If this solution does not work,
stop operation immediately and contact the “Repair Service Center“ (see back page) for assistance.
→May result in injury if you continue use with high stimulation under such circumstances.
●Do not use with the back pad removed.
→May result in personal injury.
●Do not fall asleep in the chair during a massage session.
→May result in personal injury.
●
Keep massage sessions to no longer than 15 minutes. Do not exceed 5 minutes for an area-specic massage of any particular part of the body.
→Continuous use for extended periods of time can result in over-stimulation, which could cause the opposite of the desired eect, or even injury. The
total amount of time for a daily massage should be limited to about 30 minutes keeping appropriate intervals between each massage session.
●If your leg or foot comes out of the leg rest during the massage, do not try to force it back in.
→Undue force may result in damage to the mechanism.
●If your arm comes out of the upper arm unit or forearm unit during the massage, do not try to force it back in.
→Undue force may result in damage to the mechanism.
●This appliance has heated surface. Persons insensitive to heat must be careful when using the appliance.
Unplug
the chair
●If there is a power outage or the possibility of a power outage, stop the chair immediately and turn the main POWER switch to
OFF. Unplug the power plug from the wall outlet.
→Accident or injury may result if the chair is still in operating mode when the power resumes.
●
If there is a threat of lightning, stop operation immediately and turn the main POWER switch to OFF. Unplug the power plug from the wall outlet.
●
If an operation does not start, or if you nd any abnormality, stop the chair immediately and turn the main POWER switch to OFF to
prevent an accident. Unplug the power plug from the wall outlet. Contact the “Repair Service Center“ (see back page) for assistance.
→Electric shock or re caused by a short circuit may result if the chair is left plugged in under such circumstances.
Safety Precautions: After Use or When Not in Use
Caution
Prohibited
●Be sure to turn the Main POWER switch to oafter every use and to unplug the power plug from the wall outlet.
→An accident or injury may result if children or pets play with the chair.
●Do not use the power cord for any other products.
●
After using the chair, be sure to return the reclining seat back to its upright position and lower the leg rest to its lowest position.
●Wipe the chair oafter every use, and store the chair in a place with low humidity.
●Do not place any object on the chair.
●Cleaning and user maintenance shall not be made by children without supervision.
→May result in accident or injury.
Unplug
the chair
●Hold the power plug when unplugging from the wall outlet. Do not pull on the power cord.
→May result in electric shock or re caused by short-circuiting.
●
When cleaning the chair, make sure to unplug the power plug from the wall outlet rst. Do not plug or unplug the power plug with wet hands.
●If the chair is left unused for a while, be sure to unplug it from the wall outlet.
→Insulation degradation by dirt or moisture may cause electric shock, or re due to short-circuit.
Other Precautions
Warning
Prohibited
●Do not stand on the chair. Do not make a major impact or sit on any part of the chair other than the seat.
→Personal injury or damage to the chair may result if the chair tips over.
Do not
disassemble
●Do not try to repair any malfunction of the chair. Contact the vendor or the “Repair Service Center“ (see back page) for assistance.
●For safety, if the power cord is damaged contact the “Repair Service Center“ (see back page) for assistance.
●Do not modify or remodel the chair.
→May result in re, electric shock, or injury.
Caution
Required Action
●If you lend, sell, or otherwise transfer the chair to another party, make sure to include this Operating Manual.
Note
●Before disposing of the product or its accessories, consult your local authorities about the proper procedure.

[MAIN FEATURES]
4
MAIN FEATURES
Benets
As a therapeutic massage device for household use, the Inada Chair provides the
following benets:
●Relieves fatigue ●Alleviates muscle fatigue ●Relieves muscle pain
●Improves blood circulation ●Relieves muscle aches
Main Features
Compact and high-performance
New Hybrid Massage Function
The chair has a compact, high-performance design
enabling a roller massage from the shoulders to
the lower back, and an air massage of the buttocks
and legs, and also from the shoulders to the
ngertips.
Optic sensors provide for
Automatic Shiatsu Point Locator Function
Automatically locates shiatsu points which vary
from person to person. This allows for an eective
massage that tailors itself to your size and shape.
Easy-to-see LED
Stylish Remote Control
An LED lights up for the selected program, making
the buttons easy to understand and use. Also, the
remote control semicircle area displays LEDs for
the shoulder position search and operations inside
the panel of the remote control.
Easy to adjust to the most comfortable position
Automatic Reclining Function
The seat back can be reclined to any angle
between approx. 115° and 165° from the oor. The
angle of the leg rest also can be adjusted up to
approx. 90° according to your preference.
Air massage kneading
Full Body Air Massage Function
The chair performs a full body air massage from
the leg rest that massages the feet and calves, seat
that massages the buttocks, and arm/shoulder
units that massage from the shoulders to the
ngertips.
Boost the power with just one button
Addition of a Max Intensity Mode
In addition to intensity adjustment using individual
buttons as in previous models, a Max Intensity mode
button has been added that can boost the overall
power of a massage with just one touch. When a
preset program or manual selection program is
selected, the massage operation can be changed to
Max Intensity mode.
Relieve any kind of fatigue
Various Program Functions
Preset programs allow you to select the optimal
program according to your purpose, while the
manual selection mode allows you to combine
functions to suit your particular needs.
Warm on hand and foot
Heater for Fingers and Toes
The chair is equipped with heaters for the
ngertips and toes.

[COMPONENTS & DESCRIPTION]
a
b
d
f
e
c
f
b
e
d
⑪
⑩
⑨
④
1
2
③
1
③
2
⑰
⑥
⑤
①
⑧
⑦
⑬ ⑫⑭
⑯⑮
②g
h
5
COMPONENTS & DESCRIPTION
Chair
①Headrest
②Back Pad
③Armrest (right)
・1 Shoulder Unit
・2 Arm Unit
④Armrest (left)
・1 Shoulder Unit
・2 Arm Unit
⑤Seat
⑥Leg Rest
⑦Remote Control
⑧Remote Control Pocket
⑨Reclining Seat Back
⑩Back Cover
⑪Wheels
⑫Main POWER Switch
⑬Power Connector
⑭Cord Connector
⑮Power Cord
⑯Plug
⑰
Rollers
Normally stored inside the upper
part of the seat back.
aArm Air Cushion
/2 each on left and right
bArm Air Cushion
/4 each on left and right
c Seat Air Cushion /x 1
d Calf Air Cushion /x 6
e Instep air cell /x 8
f Sole air cell /x 2
gPalm Heater
/1 each on left and right
hFoot Cover Heater
/1 each on left and right

[COMPONENTS & DESCRIPTION]
10
6
Remote Control
①Button
Turns the remote control power ON and OFF. Pushing the
POWER button while the chair is activated causes the
rollers to return to the starting position, after which the
chair turns itself o.
The button lights in green while the power to the remote
control is ON, lights in orange while the power is OFF, and
ashes in red while the chair is stopped in an emergency.
②EMERGENCY STOP Button
Use this button to shut the chair oimmediately in an
emergency or if there is a malfunction during operation
of the chair. The rollers will stop immediately.
③Roller Position Display The position of the roller during the massage is
displayed.
④Shiatsu Point Locator
Indicator
A light indicates when the shiatsu point locator is
operating and when the operation has nished.
⑤Max Intensity Mode Button Selects Max Intensity mode.
⑥Preset Program Buttons 1 Selects the corresponding program.
⑦Leg Rest Button Use to adjust the angle of the leg rest.
⑧Reclining Button Use to adjust the angle of the reclining seat back.
⑨ROLLER-Position Adjustment
Buttons
Use to adjust the shoulder position while the shiatsu
point locator is operating, and to adjust the roller
position during manual selection mode.
⑩Preset Program Buttons 2 Selects the corresponding program.
⑪Intensity Adjustment Buttons Adjusts the intensity of air pressure.
⑫Manual Selection Buttons Basic operations or special operations can be selected.
⑬
Air Massage Buttons
Selects among arm, back or leg air massage.
*These 3 air massage types can all be selected at the
same time.
⑭
Automatic Raise Cancel Button
The automatic seat reclining raise operation when the
program is completed can be set ON/OFF.
⑮Hand and Foot Heater Button The hand and foot heater can be switched ON/OFF.
Warning ●Do not spill water and/or other liquids on the remote control.
●Do not handle the remote control with wet hands.
Caution ●
Do not sit on the remote control. Do not drop or step on the remote control. Do not pull the remote control cord forcibly.
●Do not use pointed or hard objects to push the buttons.
→May result in damage to the remote control.
Remote Control/Inside the Panel
①②
④
⑧
⑨
③
⑤
⑥
⑦
Panel
ON
⑬
⑫
⑪
⑩
⑮
⑭

[BEFORE USE]
7
●This product is shipped with the reclining seat back in its fully reclined position. Be sure to raise
the seat back to its fully upright position.
●Do not expose the chair to sudden bursts of heat. If the room where the chair is to be used is cold,
turn the heat up slowly. If the chair is moved from a cold place into a heated room, wait one hour
before using the chair.
→Condensation could occur in the moving parts of the chair, which may compromise performance.
Installation
Allow for at least 50 cm (20 inch) clearance behind and in front of the chair when reclining so as to be able
to recline the seat back fully without obstruction.
Caution
●Do not install the chair in an area of high humidity, such as a bathroom or sauna.
●Install on a at, level surface only.
●Do not use in areas of high debris or dust content. Do not use where the ambient temperature is 40°C (104°F) or over.
●Do not install the chair where it can come into contact with direct heat, such as direct sunlight or a radiator.
●Keep re sources such as cigarettes and ashtrays away from the chair.
Checking the Supplied Items
Check that the chair and the other items are all in the package.
* This product is shipped with the armrests being installed.
For removing the armrests, see page 8.
●
To avoid damaging oor surfaces and to minimize the chair noise, it may be better to install the chair on a
carpeted surface or to lay a piece of carpet under the chair.
(Do not install on an electric carpet.)
●The chair is heavy, so please be careful when unloading it so as not to damage oor surfaces.
●
Install the chair at least 1 m (39 inch) away from TVs, radios, and other audio or video equipment. Otherwise
they may make noises aected by the operation of the chair.
●
The load to the oor per 1 cm2(0.15 inch2) is approximately 2.3 kg (5.1 lb), with a person weighing 100 kg
(220 lb) sitting on the chair.
BEFORE USE
50 cm
(20 inch)
50 cm
(20 inch)
Items IncludedChair
Chair
T-shaped WrenchAC Cord
Remote Control Pocket
Operating Manual
(this document)
Foot Shiatsu Pads (L/R) Shiatsu Sheet ×2

[BEFORE USE]
Caution
8
How to Remove and Install the Armrests
If the clearance of the transportation passageway is less than 87 cm, removing the armrests is recommended
before transporting the chair.
Minimum product width when armrests installed: Approx. 83 cm
Minimum product width when armrests removed: Approx. 61 cm
For safety, before removing or installing the armrests, turn othe main power and disconnect the power cord
connector from the power connector on the chair.
*For installation, perform the procedure in reverse.
Read the installation precautions carefully.
①Open the zipper on the armrest.
②Remove the air hose and harness.
●To prevent disconnection, be sure to check the connection
after connecting by lightly pulling the connector.
●If the connector is not connected properly, an error is
generated. After connecting, be sure to turn on the main
POWER switch to check for errors.
●Installation precautions
Insert the power cord into the power connector, turn on the main
power and use the reclining button on the operating mechanism to
raise the chair to its fully upright position. Then, pull the leather by
hand to straighten out the wrinkles, and close the zipper.
*For details on turning on the main power, see page 10.
●Installation precautions
Electric Wire
Red Air Hose
Black Air Hose
White Air Hose
Electric Wire
Arm Rest(Left) Arm Rest(Right)

[BEFORE USE]
9
③Remove the screws and washers. (3 locations on each side, shown by the dotted line circles)
①②
③
●Installation precautions
Install by using the T-shaped wrench in the direction shown in the diagram. (Ensure that the washer direction is
correct.)
If the screw is installed at an angle, the threads may be crushed.
Make sure it is not at an angle.
④Remove the armrest in the order of a, then b.
a
b
●Installation precautions
Pass the air hose and harness through the rectangular hole on the armrest. (4 on each side)
*Be careful not to use the wrong hole.
Align the shaft on the chair with the hole on the armrest, and insert the armrest.
*Make sure that the operating mechanism cable does not pass between the chair and the armrest.
The operating mechanism cable may break.
*Make sure that the fabric on the inner side of the armrest is not caught by the shaft.
BEFORE USE
Cover
Fabric Washer
(Concave Surface)
Screw
Air Hose, Harness
Rectangular Hole

[BEFORE USE]
10
How to Transport or Move the Chair
Before moving the chair, turn othe main power, unplug the power plug from the wall outlet, and also disconnect the
power cord connector from the power connector on the chair.
To Move with the Wheels To Carry
Raise the reclining seat back to its upright position, hold
the sides of the leg rest, and then move the chair on the
wheels by lifting and holding up the front part of the chair.
Fully recline the seat back and carry the chair by holding
the handle on the upper part of the back cover and the
sides of the leg rest.
■The chair is very heavy, so be careful not to hurt your lower back when transporting or moving it.
■The remote control is attached to the chair, so make sure that it does not fall when moving the chair.
Caution
●Do not move the chair while someone is in it.
●Before moving the chair, turn othe main power, unplug the power plug from the wall outlet, and also disconnect the
power cord connector from the power connector on the chair.
→The power cord may be damaged, resulting in re or electric shock.
Main Power Connection
①First, plug the power
cord into the cord
connector located at the
front right of the chair.
Then, plug the other end
into the wall outlet.
②Set the main POWER
switch located on the
right side of the chair set
to ON.
*If the main POWER switch is turned ON while the rollers are stopped partway, they will automatically return to the starting position (upper part of the
seat back) and then stop.
Warning Caution
●Do not use with any type of transformer device.
→May result in damage to the chair or electric shock.
●Before plugging the power cord into the wall outlet, make sure that the power
switch is set to OFF.
●Make sure that the plug on the power cord is inserted fully into the wall outlet.
●Before using the chair for the rst time, turn on all the switches in order
as indicated in this Operating Manual to check that the chair is operating
properly.

[BEFORE USE]
11
①Place the remote control pocket on the
armrest (right).
②There is Velcro for installing the remote control pocket on the
inside of the armrest (right). Wrap the remote control pocket
around the armrest (right) to install it.
BEFORE USE
Checking the Seat Cover
Before using the chair, check the seat cover for tearing with the following procedure.
①Peel open the Velcro at the top. ②Fold the back pad forward, and check by touching with
your hands that the chair fabric is not damaged.
Velcro
Back Pad
Chair Covering
Caution ●Be sure to check for tearing on the chair before every use, as shown in the illustration. Also, check the other parts for
tearing. Unplug the chair and contact the “Repair Service Center“ (see back page) for assistance. Never use the chair
with the chair covering removed or with holes or tears in the covering, because doing so is extremely dangerous.
How to Install the Remote Control Pocket
Attach the supplied remote control pocket to the arm rest (right) as shown in the diagram below.
Velcro
Remote control pocket
Armrest (right)
Place on the
armrest (right)
Wrap around the
armrest to install
Insert the remote control
into the pocket for use.

[POSITION ADJUSTMENT]
12
POSITION ADJUSTMENT
How to Sit
When the chair is o, the rollers are normally drawn back into the left and right sides of the upper part of
the seat back (Storage Position). For safety, rst check the position of the rollers. If they are in any position
other than the storage positions, turn the main POWER switch ON before sitting down to allow the rollers
to return to their storage position. When you nish checking, sit down slowly in the center of the seat.
Caution
●Do not sit down on the chair with the leg rest raised.
→Any sudden impact on the leg rest could cause damage to the mechanism. Also, an accident or injury may result if the chair tips over.
●Before using, raise the reclining seat to its fully upright position. Then recline the seat back slowly to the most
comfortable position, remembering to start owith a lighter massage.
Caution
●Do not use the shoulder unit and arm unit
for anywhere other than your shoulders and
arms respectively.
→May result in personal injury.
●If your arm comes out of the shoulder unit or
arm unit during the massage, do not try to
force it back in.
→Undue force may result in damage to the
mechanism.
●Do not massage your elbows. Also, be sure
that your palms are facing down when
massaging your arms.
→May result in personal injury.
Caution ●When you sit on or stand up from the chair,
be aware of the projecting parts on the foot
sections.
●Place your elbows between the
arm unit and shoulder unit.
How to Use the Armrest
Place your arm as shown in the diagram below
so that your elbow is between the arm unit and
shoulder unit.
If you want to enhance the intensity of massage,
put the Shiatsu sheets under your wrists.
●Insert so that your palm is
facing down.
How to Use the Shiatsu Balls
The accessories for foot Shiatsu pads (strong, weak)
can be placed on the foot sections for use. The
used Shiatsu pads can be selected according to the
individual’s preferences.
●Rotate the shoulder unit to the desired
position before starting the massage.
Foot Section

[POSITION ADJUSTMENT]
13
Leg Rest Extension and Retraction
How to Use the Leg Rest
■To raise the leg rest
Press the top LEG REST button to raise the leg rest.
■To lower the leg rest
Press the bottom LEG REST button to lower the leg rest.
Vertical Adjustment
Warning
●Make sure no one, especially children or pets, is in the way when lowering the leg rest. Be careful that people and/or
objects are not caught under the leg rest.
●Do not release your hands suddenly while lifting the leg rest by hand.
Caution ●Do not place anything other than legs and feet on the leg rest.
When you sit in the chair and raise the leg rest to the specied height, it automatically adjusts.
*Retracts
approximately
27 cm (10.6 inch).
If it stops mid-operation, press the button again.
When you press the button for approximately 2
seconds, the leg raise (lower) operation automatically
operates.
Hold Function
POSITION ADJUSTMENT

[POSITION ADJUSTMENT] [AFTER USE]
14
How to Use the Reclining Seat Back
■To raise the reclining seat back
Press the top RECLINE button to raise the reclining seat back.
■To lower the reclining seat back
Press the bottom RECLINE button to lower the reclining seat back.
Reclining Movement Range
Warning ●Make sure no one, especially children or pets, is in the way when lowering the reclining seat back. Be careful that people
and/or objects are not caught behind the reclining seat back.
The chair reclines up and down in conjunction with the movement of the seat back and leg rest.
If it stops mid-operation, press the button again.
Hold the button for about 2 seconds to raise (or lower) the
reclining seat back automatically*.
How To Use The Heater
Press the Heat button to turn on the heater.
The button light also turns on.
Press the button to turn the heater on or o.
*The seat back and leg rest move to their maximum positions and then stop.
Hold Function
AFTER USE
While making sure there is nothing in the surrounding area, return the reclining seat back
to its upright position and lower the leg rest to its lowest position.
Turn othe main POWER switch on the front right of the chair!
Unplug the power plug from the wall outlet. This will save energy because no standby power
will be consumed.
Caution
●Be sure to turn the main POWER switch to oafter every use and to unplug the power plug from the wall outlet.
→An accident or injury may result if children or pets play with the chair.
●After using the chair, be sure to return the reclining seat back to its upright position and lower the leg rest to its lowest
position.
●Wipe the chair oafter every use, and store the chair in a place with low humidity.
●Hold the power plug when unplugging from the wall outlet. Do not pull on the power cord.
●If the chair is left unused for a while, be sure to unplug it from the wall outlet.
●Be careful not to tangle yourself in the cords and trip over.

[CARE AND STORAGE]
15
CARE AND STORAGE
Storage
●After wiping oany dust or dirt, store your chair in a place that is relatively dry.
●If the chair is left unused for a while, put a cover on it that will protect it from dust and dirt.
●Pets can sometimes chew on power cords, so try to keep pets away from the chair even when it is being
stored.
Caution ●Do not install the chair where it can come into contact with direct heat, such as direct sunlight or a radiator.
Care and Maintenance
Caution ●
When cleaning the chair, be sure to unplug the power plug from the wall outlet rst. Do not plug or unplug the power plug
with wet hands.
[Caring for the Back Pad and Covers]
Soak a piece of soft cloth in lukewarm water in which a small amount of mild detergent has been added.
Then thoroughly wring it out before cleaning oany spots or grime.
Caution ●The fabric color can change if the chair is in contact with vinyl covers or wall coverings for a prolonged period of time.
[Caring for the Remote Control]
Wipe dirt othe remote control with a dry cloth.
●Never use a moistened or wet cloth. →May result in a mechanical failure.
[Caring for Other Plastic Parts]
Soak a piece of soft cloth in lukewarm water in which a small amount of mild detergent has been added,
thoroughly wring it out, and clean oany spots or grime. Then wipe with a dry cloth so that no detergent
residue remains.
●Do not use alcohol-based or other household cleaning products or abrasives because they can scratch or crack the
nish or cause color to fade.

[PROGRAMS & SELECTION]
16
Preset Programs The preset programs make it easy to select a program that suits
your preferences or objectives.
Healthcare Programs
Full Body & Stretch
This program includes light stretching in a full-body massage.
Stretch All
This program includes light stretch actions where the entire
body is stretched.
Full Body
This program is recommended for persons who feel symptoms
such as lack of energy or fatigue.
These programs are for
recovering from muscle
fatigue.
Low Body
This massage is focused on the lower half of the body.
Warm Up
This program is for gently exing your muscles before exercise.
It can also help to wake up your body in the morning.
Cool Down
This program is for balanced exing your muscles after exercise. We
recommend using this program to prevent any next-day fatigue.
Manual Selection
You can combine your favorite massage types. You can also adjust the
speed, intensity, and roller positions.
PROGRAMS & SELECTION

[PRESET PROGRAMS]
ON
❹
17
Preset Program Massages
●6 automatic programs provide a variety of dierent massages to relieve fatigue.
●With the preset program buttons, you can choose your favorite program to give you a massage
according to the preset menu.
PRESET PROGRAMS
❶Press the button.
If no selection is made within 5 minutes, the power shuts o
automatically.
❷Press the desired program button.
The chair will recline for a short time. Then, the
shiatsu point locator indicator turns on and
shiatsu point locating is performed.
[Note]
Sit as far back as possible in the chair and put
your head against the headrest in a relaxed
manner. Shiatsu points cannot be accurately
located if you are not properly seated.
❸The shoulder positions can be adjusted.
After the shiatsu points are located, the ROLLER buttons ash.
The shoulder positions can be adjusted while the buttons ash. If
no adjustment is required, do not use these buttons.
▲
The rollers move up
while this button is
pressed.
▼
The rollers move down
while this button is
pressed.
Shoulder Position Adjustment
If the shoulder position is not correct, adjust the shoulder position while the
ROLLER buttons are ashing.
Too High
Too Low
Correct
Position
❶
❷
❷
❸
❹
❹The program starts.
When shiatsu point locating is completed, the Complete light turns on
and the program starts. During operation, you can adjust the mechanical
intensity, adjust the air intensity or cancel the air operation.
Table of contents
Other FAMILY INADA Indoor Furnishing manuals
Popular Indoor Furnishing manuals by other brands

MAJA Möbel
MAJA Möbel 4052 Assembling instructions

Intercon
Intercon SM-BR-4325FS-TUS-FB Assembly instructions

Alice's Home
Alice's Home Astrid ICHRASVV 2 Series manual

KEUCO
KEUCO Edition 400 Series Instructions for use

BATHCO
BATHCO LAUNDRY installation instructions

Balzar Beskow
Balzar Beskow LINE B-305R Assembly instructions

Coaster
Coaster 203500Q Assembly instructions

burgbad
burgbad Lin20 M1263 FITTING INSTRUCTIONS AND OPERATING MANUAL

Ashley
Ashley Signature 141635 Assembly instructions

GLITZHOME
GLITZHOME Midcentury GH2001100004 Assembly instruction

Alera
Alera ALE-MX4517 manual

Möbel AS
Möbel AS WNZ431 Assembling Instruction