FARM SCAN Jackal User manual

JULY 2020
For Serial Numbers 7000-9999

CONTENTS
GENERAL DESCRIPTION ............................................................................................ 1
INSTALLATION ........................................................................................................... 2
CONNECTIONS .......................................................................................................... 3
INSTALLING SENSORS ............................................................................................... 9
OVERVIEW .............................................................................................................. 13
SPRAYER (WIZARD) – CONTROL VERSION & SPRAY ............................................... 16
AREA & SPEED METER SETUP (WIZARD) ................................................................ 21
AREA & SPEED METER USING GPS SETUP (WIZARD) ............................................. 24
TACHOMETER - RPM METER SETUP (WIZARD) ...................................................... 25
FLOW METER SETUP (WIZARD) .............................................................................. 27
SLIPPAGE METER (WIZARD).................................................................................... 30
RATE MONITOR – LIQUID ....................................................................................... 31
RATE MONITOR – SOLID ......................................................................................... 32
BATCH METER (JACKAL CONTROL ONLY) ............................................................... 34
BIN LEVEL SENSOR .................................................................................................. 36
AIR/VOLT/DEPTH/%/TEMP PRESSURE SENSOR ..................................................... 37
TRIPS ....................................................................................................................... 40
ALARMS ................................................................................................................... 41
INPUTS .................................................................................................................... 42
GENERIC WIZARD .................................................................................................... 43
FRONT SCREEN ....................................................................................................... 43
OTHER SETTINGS .................................................................................................... 44
OUTPUTS ................................................................................................................. 45
GPS/SERIAL ............................................................................................................. 46
ABOUT JACKAL ........................................................................................................ 46
DIAGNOSTICS .......................................................................................................... 46
FACTORY RESET ...................................................................................................... 46
WRITE YOUR SETTINGS DOWN ..................................................................................
NOTES .........................................................................................................................

AM-JACKAL-35 / JULY 2020
1
GENERAL DESCRIPTION
Your new Farmscan Jackal Spray Controller or Monitor system is the result of extensive infield development
and will give many years of dependable service. Software & hardware updates are provided by Smart Ag
Systems Pty Ltd.
3 Section Spray Controller (Controller Unlock)
Once installed and calibrated, the system will automatically maintain the selected spray rate regardless of
speed or pressure variations within the limits of the sprayer pump capacity and nozzle size.
This version of the Jackal is completely unlocked, un-restricted and has the full feature set of the Jackal-
Monitor. NB: Inputs consist of 7x Pulse & 2x Varying Inputs. Simply add additional sensors to utilise the
Jackal to its full potential.
Our onboard calibration wizard makes setup a breeze! It’s simplified with the ability to enter either a factor
(pulses per unit) or simply drive/run a set amount whilst the unit is counting the pulses and let the system
calculate its own factor.
24 recordable trips allow the operator to track numerous jobs in a period of work and each input can be
used to display information using imperial and metric units.
TECHNICAL SPECIFICATIONS
Specifications below are subject to change and are based on a fully unlocked Jackal.
Power
Requirements (12Vdc)
10 – 18
VDC
@
250mA
Display
128 x 64 Mono Graphic LCD
Operating Temperature
0 to
50
˚
c
Storage Temperature
-5 to
65
˚
c
Dimensions
135mm H
x
100mm W
x
30mm D
Sensor Inputs
9
Inputs 1-5 & 8-9
(Square Wave)
Up to 400 pulses per
second (On/Off/Freq)
Inputs 6-7
Analog Voltage
0 –
5V
GPS
RS232 TX/RX
Ground
2
Output PWM
2
Output +12v
1
Output
4
Output current rating
4A/output
DISCLAIMER
The warranty offered on this Farmscan product is limited to the repair or replacement of the faulty goods.
No liability will be accepted for loss of profit or productivity. WARRANTY IS VOID if power and or sensors are
not connected as described in this guide.

AM-JACKAL-35/ JULY 2020
2
INSTALLATION
PARTS LIST
REF
PART NUMBER
DESCRIPTION
QTY
1
A-Jackal
Jackal Monitor
1
2
AH-407
Mounting Bracket
1
3 ^
P-321 x1
P-322 x1
11 Way Input Plug
Green & Grey
1 each colour
4 ^
AC-105
5m Power Cable
1
5 ^
HM-506
Screw Driver
1
Not Pictured
AM-200
Warranty Card
1
Not Pictured
AM-Jackal
Manual
1
6 *
AC-4501/T
Jackal Tractor
Harness 5m
1
7 *
AC-4501/S
Jackal Section
Harness 5m
1
^ Items
NOT
supplied when purchased as full spray control kit
* Items supplied if full control kit purchased
PARTS PICTORIAL
An additonal AC-4501/EXT – 10m extensions is available for purchase to extend the Parts 6 & 7 over a longer
implement.
MOUNTING & INSTALLATION
The Jackal Monitor & Spray Controller is
provided
with a
suction window mount. An optional RAM
style is also available for purchase at an additional cost. Farmscan Part No: AH-407-RAM
Slide
mount
onto unit and push
sideways
to lock into place. Make sure you hear a c
lick
of the
mount
locking
into
place.
Place in a
convenient position
on the
windscreen
and using the
toggle
lever
pictur
ed above (Item 2),
push all the way to the
bottom
until lever locks into
position.
Note:
Monitor should
be
mounted
in a clearly visible
position
in the cab for the
operator, but
not in
a
position where
it is
subject
to
intense
heat or
moistur
e.
1
2
3
4
5
6
7

AM-JACKAL-35 / JULY 2020
3
CONNECTIONS
The connector on the rear of the Jackal Controller has the following connection points available for use
POWER CONNECTION
Power connection must come direct from the battery terminals. WARRANTY IS VOID if power is not
connected as described in this section.
The supplied harness comes pre-terminated; however, this information is important if required in the future.
1. Connect power cable supplied DIRECTLY TO BATTERY
2. Ring terminals are used for battery connection and the bare end used to connect to the rear Jackal.
(Refer above image for power connection)
3. Connect Ground to BATT -VE, Terminal B11 using the RED with BLACK stripe wire
4. Connect +12 Volts (+battery terminal) to BATT +VE, Terminal B10 using the RED wire
5. Ensure that the battery connection to the Jackal is +12 Volts
Connecting 24V to the Jackal will VOID WARRANTY
Disconnect the terminal plugs
from the Jackal if ARC
WELDING on machinery

AM-JACKAL-35/ JULY 2020
4
REAR CONNECTIONS (MONITOR & CONTROL VERSION)
The connector on the rear of the Jackal Monitor & Controller has the following points available for use when the
supplied Tractor & Section/Implement harness is not used.
A
BOTTOM ROW (GREEN PLUG)
B
TOP ROW (GREY PLUG)
A1
INPUT 1
Prox / Reed / High-Low / On-Off / Alarm
B1
GROUND
Earth / 0v
A2
INPUT 2
Prox / Reed / High-Low / On-Off / Alarm
B2
INPUT 7
Varying Voltage Sensor
A3
INPUT 3
Prox / Reed / High-Low / On-Off / Alarm
B3
INPUT 8
Prox / Reed / High-Low / On-Off / Alarm
A4
INPUT 4
Prox / Reed / High-Low / On-Off / Alarm
B4
INPUT 9
Prox / Reed / High-Low / On-Off / Alarm
A5
INPUT 5
Prox / Reed / High-Low / On-Off / Alarm
B5
+12v OUT
Supply Out / Sensor Power
A6
INPUT 6
Varying Voltage Sensor
B6
OUT 6
Dump
A7
GROUND
Earth / 0v
B7
OUT 5
Section 3
A8
OUT 2
GND/+12v/Run/Hold/Alarm/Freq/Batch
B8
OUT 4
Section 2
A9
OUT 1
GND/+12v/Run/Hold/Alarm/Freq/Batch
B9
OUT 3
Section 1
A10
+12v In
+12v Battery
B10
RS232 TX
From GPS
A11
-Ve In
Ground / GND Battery
B11
RS232 RX
From GPS
• B5 supplies 12v out to sensors when the Jackal is turned on
• Free prox INPUTS maybe be used as the remote/run hold function
o Excludes Varying Voltage Inputs
Need an extra Prox Input?
Consider swapping your wheel sensor
input for out T-135 GPS Speed sensor

AM-JACKAL-35 / JULY 2020
5
REAR CONNECTIONS (CONTROL VERSION & SPRAY)
The Jackal Spray Controller harness comes pre-terminated for ease of install and convenience.
The following table outlines the pre-termination of this cable.
A
BOTTOM ROW (GREEN PLUG)
B
TOP ROW (GREY PLUG)
A1
INPUT 1 / NOT USED
B1
GROUND / GPS PIN 5
A2
INPUT 2 / FLOW SENSOR
B2
INPUT 7 / NOT USED
A3
INPUT 3 / TANK LEVEL SENSOR
B3
INPUT 8 / NOT USED
A4
INPUT 4 / WHEEL SENSOR
B4
INPUT 9 / NOT USED
A5
INPUT 5 / NOT USED
B5
+12v OUT / COMMON SENSOR POWER
A6
INPUT 6 / PRESSURE SENSOR
B6
OUT 6 / DUMP VALVE
A7
COMMON SENSOR GROUND
B7
OUT 5 / SECTION 3
A8
OUT 2 / MASTER MOTOR -
B8
OUT 4 / SECTION 2
A9
OUT 1 / MASTER MOTOR +
B9
OUT 3 / SECTION 1
A10
+12v IN / +12V BATTERY
B10
RS232 TX
A11
-Ve IN / BATTERY GROUND
B11
RS232 RX
Notes as below:
• The Jackal sprayer harness is wired to suit the Farmscan control valve bank (see below)
• The Jackal Harness comes pre-terminated with Packard plugs & Pins
o Adapter cables maybe purchased or included with some kits (Page7)
• This cable can be modified for different valve bank assemblies.
• Please refer to your implement supplier or auto electrician to determine the current requirement and wiring
if you are not using a Farmscan control valve bank.
• The Jackal controller should only be connected directly to 3-wire motorised valves.
• If you are connecting to a 2 Wire section valve (E.g., Arag or Hardi) you will require a 2-3 Wire Converter
(Farmscan Part Number A-2091) These are available to order at an additional cost.
Example – Farmscan 3 Section Valve Bank
(Farmscan Part Number AA-AF-CONTROL/3 or /3-D with Dump)

AM-JACKAL-35/ JULY 2020
6
TRACTOR HARNESS (CONTROL VERSION & SPRAY)
Overview of Tractor Harness as below
Connect to rear of Jackal
Optional GPS Connection for
Ground Speed
12v – To
Battery
Sensor
Connector
Power
Connector to
Sensors
Jackal Tractor
Harness
Part #
AC-4501/T
P2 - GREY
P1 - GREEN

AM-JACKAL-35 / JULY 2020
7
IMPLEMENT/SECTION HARNESS (CONTROL VERSION & SPRAY)
Overview of Implement/Section Harness as below
Connect to implement as required. Unused connectors and wires should be taped back to
avoid weather corrosion or accidental shorting and damage.
NB: All Red Wires are +12v (live when Jackal is on) – DO NOT SHORT
Jackal Implement
& Sectional
Harness
Part #
AC-4501/S
The Jackal Implement Harness allows for the
following connections
• Sections 1-3 (3 Wire)
• Flow Control Valve (2 Wire)
• Dump (Optional)
• Pressure
• Wheel Input (Speed)
• Tank Level Sensor
• Flow Meter (3 Wire)
NB: The Jackal harness comes pre-terminated
with Packard’s. Kits purchased directly may
include adapters as below.
Packard Adapters are as follows:
• AC-7722 – Packard to Flow Control
• AC-7721 – Packard to Section Valves

AM-JACKAL-35/ JULY 2020
8
SPRAY HARNESS OVERVIEW (CONTROL VERSION & SPRAY)
AC-7721 - Packard to Section Valve
AC-7722 - Packard to Control Valve

AM-JACKAL-35 / JULY 2020
9
INSTALLING SENSORS
The following examples will help to determine appropriate sensor input connections into the Jackal IF you choose to
alter the pre-terminated cable to your specifications or have purchased the fully unlocked Jackal Control.
TWO WIRE “REED” – BLACK END SENSOR (OLD SENSORS)
KIT # 1007P, 2009, 2076
These kits will all include a “reed” type sensor. The reed type
sensor is a 2 wire sensor (normally black end) and only uses a
ground/earth wire and a signal wire.
The diagram to the right shows which terminals to connect your
sensors to.
Insert the black ground wire to either (A7 or B1) and the
white/coloured signal wire into any (A1-A5 or B3-B4)
Use the wizard to setup the port and calibrate a sensor once
installed.
THREE WIRE – PROX SENSOR OR 3 WIRE FLOW METERS (NEW SENSORS)
KIT # AA-2011P, AA-123P, AA-125, AA-242, AA-230X, AA-232X, AA-231
These kits will all include a “square wave” type sensor. The sensor
is 3 wires and uses a ground/earth wire, a signal wire and a 12v
power wire.
These inputs are also used with 3 wire (square wave) flow meters.
The diagram to the right shows which terminals to connect your
sensors to.
Insert the ground wire to either (A7 or B1) and the sensor wire into
any (A1-A5 or B3-B4) and the power wire to (B5)
Use the wizard to setup the port and calibrate a sensor once
installed.
NB: A Proximity sensor can be used for wheel speed or RPM.

AM-JACKAL-35/ JULY 2020
10
THREE WIRE “ANALOGUE/VOLTAGE” – PRESSURE SENSOR OR DEPTH SENSOR
KIT # AA-114, AA-119-H, AA-119-L, AA-430
These kits will all include an “analogue” type of sensor. The
analogue sensor is 3 wire and uses a ground/earth wire, a signal
wire and a 12v power wire.
Typical sensors would include Pressure & Depth.
The diagram to the right shows which terminals to connect your
sensors to.
Insert the ground wire to either (A7 or B1) and the sensor wire into
(A6 or B2) and the power wire to (B5)
Use the generic wizard to setup the port and calibrate a sensor
once installed.
NB: The AA-430 (Depth Sensor) is powered by 5v – Please contact us to discuss powering options via the Outputs
Menu
THREE WIRE “BIN/TANK LEVEL”
KIT # 2060, A-2220P, A-2221
These kits will all include an “on/off, high/low, empty/full” type of
sensor. The analogue sensor is 3 wire and uses a ground/earth wire,
a signal wire and a 12v power wire.
The diagram to the right shows which terminals to connect your
sensors to.
Insert the ground wire to either (A7 or B1) and the sensor wire into
any (A1-A5 or B3-B4) and the power wire to (B5)
Use the generic wizard to setup the port and calibrate a sensor
once installed.
GPS
KIT #T-135
GPS units supplied from Farmscan are pre-programmed and
ready to use with the Jackal Monitor.
The diagram to the right shows which terminals to connect your
GPS to.
Insert the black or green wire to (B1) and the white or yellow
wire into (B11) and the red wire into (B5)
Use the wizard to setup the port and calibrate once installed.
NB: If you BYO GPS please ensure: GGA, VTG, RMC, 5Hz and a
baud rate over 19200kbps.

AM-JACKAL-35 / JULY 2020
11
BATCH (SOLENOID)
KIT # 1501
The Batch function is designed to measure bulk water into a spray
tank via either a bottom or top fill system. The minimum flow
rate for effective operation is 75 L/min to a maximum of
750L/min using our standard 2” flow sensor.
Water may be pumped, or gravity fed through the flow sensor,
which will give accurate readings providing no air enters the
system. The Flow sensor can be installed on either the suction or
pressure side of the water delivery system, and the readout will
count up to display the total litres delivered.
Alternatively, the TANK BATCHMETER may be automated by installing either the SOLENOID SHUTOFF option which
will automatically stop the flow after the readout counts down to zero from a preset batch total.
When using the Jackal as a batch meter with liquid, please ensure the appropriate flow meter is setup as per the
previous instructions.
Insert one wire to (B5 POWER OUT) and the other wire into (A8 OUT 2)
Use the wizard & instructions to setup the port and calibrate once installed.
If water quality is doubtful, water intake should be filtered via an 80-mesh filter before the flow sensor, to avoid foreign
matter clogging / jamming the turbine. Chemicals may be introduced into the water stream without causing damage
to the flow sensor, but some chemicals may damage or reduce the solenoid diaphragm life, particularly if undiluted.
REMOTE RUN/HOLD (ACTIVATE BY INPUT)
The Jackal can connect an external Run/Hold trigger (e.g.
Remote Switch) & wire into any unused signal INPUT port
(A2-A6 & B3-B4)
This allows the Jackal to be remotely placed on hold or run
mode from an external source or switch without having to press
the Run/Hold button on the Jackal itself. When the external
Run/Hold is active on the mentioned inputs the Run/Hold
button on the Jackal is then disabled.
Insert the ground wire from your external switch to any of the
unused ports as mentioned above.
NB: In some cases, you may have to use an automotive relay to provide the appropriate ground output.
NORMALLY ON
WHEN A CIRCUIT EXISTS BETWEEN THE SELECTED
INPUT AND GROUND (GND), SELECTING NORMALLY ON
WILL RESULT IN THE JACKAL GOING INTO HOLD MODE
NORMALLY OFF
SELECTING NORMALLY OFF WILL RESULT IN THE
REVERSE I.E. THE JACKAL WILL BE IN RUN MODE UNTIL
THE CIRCUIT IS BROKEN AFTER WHICH IT WILL GO INTO
HOLD MODE.
Enable the remote run/hold via OTHER SETTINGS as further described on PAGE 44.

AM-JACKAL-35/ JULY 2020
12
REMOTE RUN/HOLD (ACTIVATE BY OUTPUT)
The Jackal Monitor has the ability to Run/Hold an external
device such as a remote clutch switch.
There are 6 outputs available on the Jackal. (A8-A9 & B6-B9)
This allows you to press the Run/Hold on the Jackal to enable an
external operation.
NB: This function is used in conjunction through an automotive
relay.
Example: Hella Automotive Relay (12v / 30A) – 4RA003510-08
Pin 86 to A9 Out 1 (Jackal +12v Run/Hold Output)
Pin 85 to A7 (Ground)
Pin 30 to 12v in (Direct to Vehicle Battery)
Pin 87 to Positive Side of clutch switch (Ensure negative/ground on other side of switch returns to battery)
Enable the remote run/hold out by:
From the front screen press
SETUP
Highlight OUTPUTS and press
SELECT
Highlight 1: NONE and press
SELECT
Press EDIT and change to
MODE: Run/Hold
Press EXIT
Run/Hold can be changed
from +12V/0V to 0V/+12V
by pressing EDIT
Press EXIT when done.

AM-JACKAL-35 / JULY 2020
13
OVERVIEW
BUTTON FUNCTIONS
1. Power On/Off button
a. Power is
turned
on by pressing the ON/OFF button for 1 second.
b. Power is
turned
off by
holding the
ON/OFF
button for 2 seconds.
2. Run/Hold button
a. The RUN/HOLD button has a dual function.
a. Press RUN/HOLD once to place the ‘MONITOR ON HOLD’.
b. Press RUN/HOLD again to resume operation.
b. The RUN/HOLD state is indicated in the top left-hand corner of the screen. When the monitor is in
RUN mode, the unit displays RUN to signify that the monitor is active.
c. When the monitor is in HOLD mode the unit displays the word “HOLD” & “BEEPS” every 2 seconds
3. Page button
a. The PAGE button is used to scroll through BATCH mode screens or Spray Control functions.
4. Select button (3 of)
a. The Jackal has 3 buttons placed directly under the LCD. These buttons will change function in different
menus.
b. The function of the button is indicated at the bottom of the screen directly above the button.
5. Navigation button (Up, Down, Left, Right, Enter)
a. The Round navigation (NAV) buttons are used to navigate UP/DOWN/LEFT/RIGHT in calibration screens
as well as scrolling through the display lines on the main screen.
b. ENTER is used to select the option highlighted onscreen.
4
3
1
2
5

AM-JACKAL-35/ JULY 2020
14
SCREEN LAYOUT
The Jackal can display one, two or three lines of live information at any one time.
Using the middle NAV/Enter button allows you to toggle between the different display modes when multiple inputs
are being used.
Example: 1 Line
Example: 2 Line
Example: 3 Line

AM-JACKAL-35 / JULY 2020
15
MAIN MENU
The level of Jackal unlock will determine what options are viewable and available to be edited.
Use the NAV button down to reveal further menu information
Wizard Run a predefined wizard for setting up the Jackal Monitor as:
• Sprayer (Automatic Mode) – Control Version
• Area/Speed Wheel
• Area/Speed GPS
• Tachometer (Fast & Slow option available)
• Flow Meter
• Slippage Meter
• Generic Wizard
Inputs Manually enable or edit ports in which sensors are connected to.
Front Screen Enable/define/order/edit/name the lines on the front screen.
Select the number of decimal places displayed and edit the alarms.
Other Change speed input, implement & section widths, external run/hold
Settings alarm notification settings (beep & on hold), language options, speed simulation for
diagnostics.
Outputs This menu is used to control the Jackal outputs. Refer to this manual and edit the outputs
described ONLY to prevent damage to external sensors connected to the Jackal.
GPS/Serial When an external GPS is connected view and ensure the GPS is setup correctly.
Setup baud rate and confirm GPS messages (NMEA messages RMC or GGA+VTG are
required) Latitude, Longitude, heading, speed, date & time.
About Jackal Shows current version of Jackal software and unlock codes installed on the unit.
Diagnostics Shows current input voltage and input diagnostics on enabled ports.
Factory Reset Returns the Jackal to factory default.

AM-JACKAL-35/ JULY 2020
16
SPRAYER (WIZARD) – CONTROL VERSION & SPRAY
The Jackal can be setup to control an application rate when using both
a speed & flow input. It offers Fully Manual, or Manual with auto dump
valve open when stopped & Full Rate Control when varying speed.
Rates and 3 sections can be controlled from the main screen
Sensors Required:
• Wheel Sensor/GPS for Speed & Area calculation
• Flow meter (any style) to display Litres
Available Connections: Refer to Installing Sensors from PAGES 9-11.
If purchased as a Spray Kit, the appropriate harness & connectors are supplied.
NB: The following setup uses information from multiple pages in
this manual.
SETUP – AUTO MODE (WIZARD) – MOST COMMON
From the front screen press
SETUP
Highlight WIZARD and press
SELECT
Highlight Sprayer and
Press NEXT
Select Spray Mode
Auto: Requires Speed &
Flow Input. Auto rate adjust
Manual: Adjust the Flow
Control Valve Manually
PAGE 18
Press NEXT to setup your
Flow Meter
NB: Please have your Pulse
Per Litre (PPL) factor from
your flow meter ready to
enter.
Press the DOWN arrow to
the Manual Ratio value of
500.00 & Press EDIT to
change the unit of Pulse.
Using the
NAV
buttons enter
the PPL factor as displayed on
the flow meter tag.
Press
EXIT
when done.
Press
NEXT
to accept the
new manual ratio (PPL)

AM-JACKAL-35 / JULY 2020
17
Using the
NAV
buttons
select how you would like
the
UOD
to be displayed on
the front screen.
Press
NEXT
You have the option to set
Alarm Min/Max points if
required. Using the
NAV
buttons select and
EDIT
as
required. Press
NEXT
Change the input name if you
desire, Press
EDIT,
or Press
NEXT
Select WHEEL or GPS to
setup the speed input. This
depends on the speed
option you have purchased.
For Wheel:
Refer to Page 21 to 23
For GPS:
Refer to Page 24
The Jackal has the ability to
have Preset Rates across the
bottom of the screen.
Example 50l/ha, 60l/ha etc.
The Step rate allows you to
easily up the rate by this
amount quickly from the
front screen.
Press NEXT
Press EDIT and change the
number of sections required
to control.
Press NEXT
Using the NAV & EDIT keys,
highlight and edit the
section width values as
required. The Section
Widths will also Total and be
displayed. Press NEXT
Using the NAV & EDIT keys,
highlight and edit the “Quick
set Rates” & Quick rate Step
Value.
Press NEXT
Using the NAV & EDIT keys,
highlight and edit the HOLD
& STOP values as described
below
Press NEXT
• The Slow Hold Speed function is used to avoid
loss of spray coverage caused by loss of pressure
when travelling too slow or when reducing the target
rate below the recommended minimum for the
nozzles.
• If the implement is travelling below this speed
(but above the minimum speed) then flow control is
regulated as if the implement were travelling at the
Slow Hold Speed.
• NOTE: Slow Hold is an optional function that can be set to operate at a minimum
speed equivalent to the minimum recommended pressure for a given target rate
(speed-based).
• STOP: Will simply put the Jackal on hold at a set speed.
Change the input name if
you desire, Press
EDIT,
Press
NEXT
If you wish to setup a Tank
Level Sensor please refer to
PAGE 36. If not, Press
SKIP
Press
NEXT
to finalise the
Wizard and return to the
front screen
THIS ENDS THE AUTO
SET WIZARD SETUP FOR
SPRAYER SETUP

AM-JACKAL-35/ JULY 2020
18
SETUP – MANUAL MODE (WIZARD) – NOT SO COMMON
The Jackal can be setup to work in MANUAL mode in the event of no wheel speed or flow meter input, or
combination of both. Manual mode simply allows adjustment of the flow control valve. In the event of a dump valve
being installed, manual mode will close the dump valve & open all sections when the Run/Hold button is pressed.
Select MANUAL: To Adjust
the Flow Control Valve
Manually
Press SKIP
Press SKIP
Press EDIT and change the
number of sections required
to control.
Press NEXT
Using the NAV & EDIT keys,
highlight and edit the
section width values as
required. The Section
Widths will also Total and be
displayed. Press NEXT
Press SKIP
Press
NEXT
to finalise the
Wizard and return to the front
screen
When you return to the
Front Screen the Jackal
needs to display a value.
The value of 1.0km/h is not
relevant. It’s simply used for
the manual fucntion
Press the Run/Hold button
You can now manually
adjust your flow control
valve by pressing the Rate +
or Rate –
Simply drive to a set speed
Press the PAGE
button to display Rate+/-
Flush
Other manuals for Jackal
1
Table of contents
Other FARM SCAN Controllers manuals
Popular Controllers manuals by other brands

Linear Technology
Linear Technology LT8390A Demo Manual

Minarik
Minarik AC100 SERIES Installation and operation instructions

Omron
Omron F3SP-U4P-TGR datasheet

YASKAWA
YASKAWA YASNAC 2000G Operator's manual

EUROSTER
EUROSTER C6RX Installation and operation manual

Allen-Bradley
Allen-Bradley FlexPak 3000 Quick reference guide