PAGE 5
Enter the width of the sections.
For Sprayers: Enter number of tips per section x spacing = width of section.
The sum of the sections must equal the application width entered on (page 1).
FOR APPLICATORS:
16 row, 17 coulter example, 30” spac-
ing.
Section 1 = 5 full rate coulters = 150”.
5 x 30” = 150”
1 half rate coulter = 15”.
150” + 15” = 165”
165” / 12” = 13.75 feet
Section 2 = 5 full rate coulters = 150”.
5 x 30” = 150”
150” / 12” = 12.50 feet
Section 3 = 5 full rate coulters = 150”.
5 x 30” = 150”
1 half rate coulter = 15”.
150” + 15” = 165”
165” / 12” = 13.75 feet
16 row, 15 coulter example, 30” spac-
ing.
Section 1 = 4 full rate coulters = 120”.
4 x 30” = 120”
1.5 rate coulter = 45”.
120” + 45” = 165”
165” / 12” = 13.75 feet
Section 2 = 5 full rate coulters = 150”.
5 x 30” = 150”
150” / 12” = 12.50 feet
Section 3 = 4 full rate coulters = 120”.
4 x 30” = 120”
1.5 rate coulter = 45”.
120” + 45” = 165”
165” / 12” = 13.75 feet
The sum of the sections must equal the application rate entered on page 1.
Press Next.