80-600042-01 RAVEN RCM SETUP 2-18-2020
RAVEN RCM
SETUP MANUAL
Refer to Operators Manual for Complete Setup Instructions
80-600042-01 RAVEN RCM SETUP 2-18-2020
PAGE 1
RAVEN RCM SETUP
Enter the Profile Name:
FAST + Model Number
(Example: FAST 9518T, FAST 8313)
Select Machine Type:
For Sprayers use: “Pull - behind Sprayer”
For Applicators use: “Liquid Fert. Tool”
Enter the Application Width.
Press Next.
PAGE 2
Leave at “1” unless multiple ECU’s are
used.
Press Next.
PAGE 3
Choose Application Mode.
FAST products only use “Liquid”.
Liquid choice selected.
Press Next.
PAGE 4
Enter number of sections (ball valves).
FAST only uses “3-wire” valves.
If the sections are unequal widths,
uncheck the box.
Example setting:
3 sections, 3-wire valve.
Box unchecked for unequal widths.
Press Next
PAGE 5
Enter the width of the sections.
For Sprayers: Enter number of tips per section x spacing = width of section.
The sum of the sections must equal the application width entered on (page 1).
FOR APPLICATORS:
16 row, 17 coulter example, 30” spac-
ing.
Section 1 = 5 full rate coulters = 150”.
5 x 30” = 150”
1 half rate coulter = 15”.
150” + 15” = 165”
165” / 12” = 13.75 feet
Section 2 = 5 full rate coulters = 150”.
5 x 30” = 150”
150” / 12” = 12.50 feet
Section 3 = 5 full rate coulters = 150”.
5 x 30” = 150”
1 half rate coulter = 15”.
150” + 15” = 165”
165” / 12” = 13.75 feet
16 row, 15 coulter example, 30” spac-
ing.
Section 1 = 4 full rate coulters = 120”.
4 x 30” = 120”
1.5 rate coulter = 45”.
120” + 45” = 165”
165” / 12” = 13.75 feet
Section 2 = 5 full rate coulters = 150”.
5 x 30” = 150”
150” / 12” = 12.50 feet
Section 3 = 4 full rate coulters = 120”.
4 x 30” = 120”
1.5 rate coulter = 45”.
120” + 45” = 165”
165” / 12” = 13.75 feet
The sum of the sections must equal the application rate entered on page 1.
Press Next.
PAGE 6
Not used unless there are special require-
ments.
Press Next.
PAGE 7
Section summary per product.
If using a switch box, switch assignment is
entered here.
Press Next.
PAGE 8
Choose pressure sensor if installed.
FAST only uses 0-250 psi.
Press Next.
PAGE 9
FAST does not use auxiliary functions,
leave unchecked.
Press Next.
PAGE 10
Standard control valve setup.
If machine has a PWM pump, choose
“PWM”.
PWM setup.
Press Next.
PAGE 11
If using ACE PWM pump, change the coil frequency to 122.
Max Pump PWM:
Enter a maximum PWM duty cycle percent to set the maximum desired output for a
pulse width modulated (PWM) hydraulic control valve. This setting limits how far the
PWM valve will open.
(Typically set at 100 psi. deadhead.)
Min Pump PWM:
Enter a minimum PWM duty cycle percent to set the minimum desired output (zero point
or shutoff point) for a pulse width modulated (PWM) hydraulic control valve).
(Typically set at 20 psi. deadhead.)
PWM Standby:
Enter desired control valve PWM duty cycle percent when all sections are off. This is uti-
lized when standby pressure control is not available (pressure sensor not available or
direct injection is installed).
(Typically set at within 10 psi of spray pressure.)
Press Next.
PAGE 12
Enter calibration number found on the
flowmeter tag.
Choose “Flowmeter Pulse/Units”.
Flowmeter calibration number entered.
Flowmeter Pulse/Units number entered.
Press Next.
Flowmeter tag calibration number.
Flowmeter tag Pulse/Units number.
PAGE 13
FAST does not use a tank fill sensor.
Enter tank capacity.
Enter current tank level.
Enter desired low tank level.
Choose alarm.
Press Next.
X
PAGE 14
Enter the desired rates.
Enter the desired rate bump.
“Rate Bump” can be used if preferred over
a predefined rate.
Decimal shift can be used for finer rates.
Example settings.
Press Next.
PAGE 15
NOTE: This setting will vary based on tip selection.
Sprayers:
Nozzle capacity at minimum psi, multiply
by the number of nozzles.
Example:
For FAST installed tips, see tip chart.
.18 x (number of tips) = minimum flow rate.
Applicators:
Can be run without entering a minimum
flow rate, but if desired, the same formula
should be used.
PAGE 16
Setup summary page.
Press Next.
PAGE 17
Not used.
For connecting to mobile app.
80-600042-01 RAVEN RCM SETUP 2-18-2020
NOTES

Popular Controllers manuals by other brands

Danfoss AFP 2/VFG 2 operating guide

Danfoss

Danfoss AFP 2/VFG 2 operating guide

Lumiax MT1050 user manual

Lumiax

Lumiax MT1050 user manual

DMC TSC-40/IC Product specifications

DMC

DMC TSC-40/IC Product specifications

Broadcom 440X user guide

Broadcom

Broadcom 440X user guide

EUROSTER UNI4 user manual

EUROSTER

EUROSTER UNI4 user manual

Orion 41710 HP-RB1 owner's manual

Orion

Orion 41710 HP-RB1 owner's manual

Sorel SFWC Installation and instruction manual

Sorel

Sorel SFWC Installation and instruction manual

Mitsubishi GOT-F900 installation manual

Mitsubishi

Mitsubishi GOT-F900 installation manual

CKD KBX-50G-BT-19N Series instruction manual

CKD

CKD KBX-50G-BT-19N Series instruction manual

Siemens SIMATIC S7-200 System manual

Siemens

Siemens SIMATIC S7-200 System manual

Lippert Components 13398-C1 Operation and service manual

Lippert Components

Lippert Components 13398-C1 Operation and service manual

Graco 3A7639A instructions

Graco

Graco 3A7639A instructions

Siemens GIB 1 Series Mounting instructions

Siemens

Siemens GIB 1 Series Mounting instructions

Aruba 6000 series installation guide

Aruba

Aruba 6000 series installation guide

Danfoss VLT AutomationDrive Design guide

Danfoss

Danfoss VLT AutomationDrive Design guide

SpaNet SV SmartStream user manual

SpaNet

SpaNet SV SmartStream user manual

Amperes VP7810 instruction manual

Amperes

Amperes VP7810 instruction manual

Festo CMMP-AS-***-M3 Series Description

Festo

Festo CMMP-AS-***-M3 Series Description

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.