Feig Electronic ID ISC.MR102 User manual

INSTALLATION MANUAL
final –public (B)
2018-01-18 –M01210-6e-ID.doc
ID ISC.MR102
For all variants

Identification
Installation
ID ISC.MR102
FEIG ELECTRONIC GmbH
Page 2 of 26
M01210-6e-ID.doc
Note
Copyright 2011 –2018 by
FEIG ELECTRONIC GmbH
Lange Strasse 4
D-35781 Weilburg-Waldhausen
Tel.: +49 6471 3109-0
http://www.feig.de
With the edition of this document, all previous editions become void. Indications made in this manual may be
changed without previous notice.
Copying of this document, and giving it to others and the use or communication of the contents thereof are
forbidden without express authority. Offenders are liable to the payment of damages. All rights are reserved
in the event of the grant of a patent or the registration of a utility model or design.
Composition of the information in this document has been done to the best of our knowledge. FEIG
ELECTRONIC GmbH does not guarantee the correctness and completeness of the details given in this
manual and may not be held liable for damages ensuing from incorrect or incomplete information. Since,
despite all our efforts, errors may not be completely avoided, we are always grateful for your useful tips.
The instructions given in this manual are based on advantageous boundary conditions. FEIG ELECTRONIC
GmbH does not give any guarantee promise for perfect function in cross environments and does not give
any guaranty for the functionality of the complete system which incorporates the subject of this document.
FEIG ELECTRONIC call explicit attention that devices which are subject of this document are not designed
with components and testing methods for a level of reliability suitable for use in or in connection with surgical
implants or as critical components in any life support systems whose failure to perform can reasonably be
expected to cause significant injury to a human. To avoid damage, injury, or death, the user or application
designer must take reasonably prudent steps to protect against system failures.
FEIG ELECTRONIC GmbH assumes no responsibility for the use of any information contained in this docu-
ment and makes no representation that they free of patent infringement. FEIG ELECTRONIC GmbH does
not convey any license under its patent rights nor the rights of others.

Identification
Installation
ID ISC.MR102
FEIG ELECTRONIC GmbH
Page 3 of 26
M01210-6e-ID.doc
Content
ID ISC.MR102 1
For all variants 1
Safety Instructions / Warning - Read before start-up ! 5
Performance Features of the readers 6
Available Reader types ............................................................................................................6
Optional accessories ...............................................................................................................6
Assembly and Wiring 7
Housing versions.....................................................................................................................7
Dimensions............................................................................................................................7
Module version......................................................................................................................... 8
Dimensions............................................................................................................................8
Connections 9
Antenna terminal ANT 1......................................................................................................... 10
DC Voltage supply on antenna connector ANT1..................................................................10
Power supply..........................................................................................................................11
Power supply via X1 ............................................................................................................ 11
Power supply via PoE (Power over Ethernet) on X4 (ID ISC.MR102-PoE) ..........................12
Power supply and interface connection on X2 (ID ISC.MR102-A).......................................13
RS232 Interface (ID ISC.MR102-A) ..................................................................................... 13
Ethernet-Interface on X2 (10/100Tbase)................................................................................ 14
USB –Interface X3 (Host communication) ...........................................................................14
Control and display elements LED 15
LED.......................................................................................................................................... 15

Identification
Installation
ID ISC.MR102
FEIG ELECTRONIC GmbH
Page 4 of 26
M01210-6e-ID.doc
Technical Data 16
Radio Approvals 18
Europe (CE) ............................................................................................................................ 18
Europe (CE) ............................................................................................................................ 19
USA (FCC) and Canada (IC)................................................................................................... 20
UL Approval - USA and Canada 22
Annex 23
Accessories............................................................................................................................23
Wall mounting kit ID ISC.MS.MR/PR-A................................................................................24
Serial data cable ID CAB.RS-A............................................................................................25
Antenna...............................................................................................................................26

Identification
Installation
ID ISC.MR102
FEIG ELECTRONIC GmbH
Page 5 of 26
M01210-6e-ID.doc
Safety Instructions / Warning - Read before start-up !
The device may only be used for the purpose intended by the manufacturer.
The operation manual should be kept readily available at all times for each user.
Unauthorized changes and the use of spare parts and additional devices which have not been
sold or recommended by the manufacturer may cause fire, electric shocks or injuries. Such
unauthorized measures shall exclude the manufacturer from any liability.
The liability-prescriptions of the manufacturer in the issue valid at the time of purchase are valid
for the device. The manufacturer shall not be held legally responsible for inaccuracies, errors,
or omissions in the manual or automatically set parameters for a device or for an incorrect
application of a device.
Repairs may only be undertaken by the manufacturer.
Installation, operation, and maintenance procedures should only be carried out by qualified
personnel.
Use of the device and its installation must be in accordance with national legal requirements
and local electrical codes .
When working on devices the valid safety regulations must be observed.
Before touching the device, the power supply must always be interrupted. Make sure that the
device is without voltage by measuring. The fading of an operation control (LED) is no indicator
for an interrupted power supply or the device being out of voltage!
Special advice for wearers of cardiac pacemakers:
Although this device doesn't exceed the valid limits for electromagnetic fields you should keep
a minimum distance of 25 cm between the device and your cardiac pacemaker and not stay in
the immediate proximity of the device’s antenna for any length of time.

Identification
Installation
ID ISC.MR102
FEIG ELECTRONIC GmbH
Page 6 of 26
M01210-6e-ID.doc
Performance Features of the readers
The Reader ID ISC.MR102 is designed for reading passive data carriers, so-called „Smart Labels“
at an operating frequency of 13.56 MHz.
The ID ISC.MR102 is suitable for all applications in which moderate reading distances are re-
quired. Also required is an external antenna connected to the Reader.
An anticollision function enables simultaneous reading of up to 100 * ISO15693 or ISO18000-3M3
transponders per second.
The Reader electronics is contained in a plastic housing having an IP30 enclosure rating.
Available Reader types
The following reader types are currently available:
Reader type
Description
ID ISC.MR102-A
Housing version with asynchronous RS232 interface
ID ISC.MRM102-A
Module version with asynchronous RS232 interface
ID ISC.MR102-PoE
Housing version with LAN interface and Power over Ethernet
ID ISC.MR102-USB
Housing version with USB-Schnittstelle
ID ISC.MRM102-USB
Module version with USB-Schnittstelle
Table 1: Reader types
Optional accessories
Optional Accessories are listed in the attachment.

Identification
Installation
ID ISC.MR102
FEIG ELECTRONIC GmbH
Page 7 of 26
M01210-6e-ID.doc
Assembly and Wiring
Housing versions
The Reader is designed for an office environment. It can be wall-mounted, in this case the wall-
mount kit should be ordered separately.
(see Appendix: Wall mounting kit ID ISC.MS.MR/PR-A)
Notes:
The distance between two readers of the same type should not fall below 4m.
Before any installation the intended position of the reader should be tested for it´s suit-
ability.
Dimensions
Figure 1: Dimensions oft he housing version (all dimensions are in mm)

Identification
Installation
ID ISC.MR102
FEIG ELECTRONIC GmbH
Page 8 of 26
M01210-6e-ID.doc
Module version
This reader version has been designed for mounting in other equipment.
Notes:
The distance between two readers of the same type should not fall below 4m.
Before any installation the intended position of the reader should be tested for it´s suit-
ability.
Dimensions
77
137
Ø3,3
Ø7
125
107,5
65
LED
ANT1
FE 698
68,5
54,5
29,5
X2
X1
X3 X4
Figure 2: Dimensions of the module version (all dimensions in mm)

Identification
Installation
ID ISC.MR102
FEIG ELECTRONIC GmbH
Page 9 of 26
M01210-6e-ID.doc
Connections
Depending on the reader variant different connectors are available. Figure 3: Connection overview
displays the arrangement and the Table 2: Connectors shows which connector can be used for the
different interface cable.
X2
X4 X1
X1X3
ID ISC.MR102-PoE
ID ISC.MR102-USB
ANT 1
ID ISC.MR102
ID ISC.MR102-A
Figure 3: Connection overview
Connector
Description
ANT 1
Antenna terminal ANT 1 (Impedance 50Ohm)
X1
Power supply 12 - 24VDC
X2
RS232 Interface
X3
USB Interface
X4
10/100Tbase Ethernet interface with RJ-45 (PoE)
Table 2: Connectors

Identification
Installation
ID ISC.MR102
FEIG ELECTRONIC GmbH
Page 10 of 26
M01210-6e-ID.doc
Antenna terminal ANT 1
A SMA socket is provided on the circuit board for connecting the external antenna.
The maximum tightening torque for the SMA socket is 0.45 Nm.
Caution:
Higher tightening torque will damage the connector.
Terminal
Description
X4
Connecting the external antenna
(input impedance 50)
Table 3: Connecting the external antenna
Note:
The input impedance for the antenna must be calibrated to a value of
50
(15
15°).
If the antenna ID ISC.ANT340240 is used a minimum distance of 20cm to any metal parts
are necessary. Otherwise there is a danger that the reader will be destroyed.
The optimum operating Q factor of the antenna should be in a range of QB = 10...20. To
determine the operating Q the antenna must be supplied with a 50 Ohm source such as
a network analyzer or frequency generator.
When connecting an antenna, ensure that it does not exceed the permissible limits pre-
scribed by the national regulations for radio frequency devices.
DC Voltage supply on antenna connector ANT1
The reader is able to provide a DC voltage on the antenna output ANT1. With this DC voltage a
external LED can be supported for example.
Note:
This DC voltage (7,5V± 1V) is designed for low current (max. 5mA) only.
Only antennas can be used which are designed for DC voltage and do not short cut DC
voltages.
For the connection of other devices (e.g. VSWR-Meter) it is necessary to check if DC
voltage is allowed.
This DC voltage is not sufficient for powering the ID ISC.DAT tuning board.

Identification
Installation
ID ISC.MR102
FEIG ELECTRONIC GmbH
Page 11 of 26
M01210-6e-ID.doc
Power supply
Power supply via X1
The reader has to supplied by a limited power supply (e.g. NEC Class 2/LPS power supply) ac-
cording IEC EN 60950, only.
Connect the 12-24 V DC/ supply voltage to socket X1 on the circuit board.
Terminal
Name
Description
X 1
X1 / inside
Vcc
Vcc –supply voltage (+)
X1 / outside
GND
Ground –supply voltage (-)
Table 4: Connecting the supply voltage
Note:
Reversing the polarity of the supply voltage may destroy the device.
The unit has to supplied by a listed NEC Class 2/LPS Power supply, only
Power supply recommendations:
To take full advantage of the Reader performance, you must use a sufficiently regulated and low-
noise power supply. When using a switching power supply, be sure that its internal switching fre-
quency is less than 300 kHz. See also: Accessories
Feig Article No
Name
Description.
1688.002.00
ID NET.12V-B-EU
Power Supply Unit
12V
Power Supply 100 - 240V AC Input Voltage,
(Continental European Plug),
with angular DC Plug 2,5mm*5,5mm
Output: 12 V DC/ ; 700mA
Ambient Operating Temperature: 0°C to +40°C
Table 5: Recommended power supply
Note:
The power supply is supplied with a DC/ plug 2.5mm x 5.5mm. This is compatible with
the readers socket X1.

Identification
Installation
ID ISC.MR102
FEIG ELECTRONIC GmbH
Page 12 of 26
M01210-6e-ID.doc
Power supply via PoE (Power over Ethernet) on X4 (ID ISC.MR102-PoE)
Optional the reader (only MR102-PoE) can be powered via the LAN connector on X4 with the use
of a PoE „Power over Ethernet“ power supply according to IEEE802.3af*, Class2 (6,49 Watt).
The DC supply can be achieved via the free pin’s 4,5 and 7,8 (Midspan-Power). Also a “Phantom
Powering” (Inline-Power) via the signal pin’s 1,2,3,and 6 is possible.
Figure 4: LAN and PoE connection
Note:
It must be ensured that the reader is supplied with 42,5 V DC (48 V DC –cable losses) at
least.
The maximum cable distance for Ethernet is 100m.
A connection of the PoE Port X4 to devices at outside building installation (e.g. con-
nected to the outside plants) is not allowed.
A shielded twisted pair STP CAT5 cable must be used.
* For detailed technical information regarding the 802.3af standard, please refer to the most
recent edition of the corresponding IEEE specification.
Article No.
Name
Description
3842.000.00
ID NET.PoEI13W-A
Power over Ethernet Supply 100-240V AC
(Continental European Plug),
Output: 48V DC/ ; 0,5A
Table 6: Recommended PoE Power Supply
X4

Identification
Installation
ID ISC.MR102
FEIG ELECTRONIC GmbH
Page 13 of 26
M01210-6e-ID.doc
Power supply and interface connection on X2 (ID ISC.MR102-A)
For the power supply connection and the connection of the asynchronous interface RS232 / 485
the reader provides a 9-pin D-Subminiature female connector.
(See also Connections).
X2
Interface
+
Power supply
2
TxD
3
RxD
5
GND
7
GND
9
Vcc
1;4;6;8
n.c.
Table 7: Connection assignment of the connector X2
For this reader a serial cable with integrated DC connector is available.
(See: Serial data cable ID CAB.RS-A).
Feig Part No.
Description
1690.000.00
ID CAB.RS-A
Table 8: Serial data cable
RS232 Interface (ID ISC.MR102-A)
Interface parameter can be configured via software protocol (e.g. ISOStart)

Identification
Installation
ID ISC.MR102
FEIG ELECTRONIC GmbH
Page 14 of 26
M01210-6e-ID.doc
Ethernet-Interface on X2 (10/100Tbase)
The Reader has an integrated 10 / 100 base-T network port for an RJ-45. Connection is made on
X2 and has an automatic “Crossover Detection” according to the 100BASE-T Standard.
With structured cabling CAT 5 cables should be used. This ensures a reliable operation at 10 Mbps
or 100 Mbps.
The prerequisite for using TCP/IP protocol is that each device has a unique address on the net-
work. All Readers have a factory set IP address. Interface parameter can be configured via soft-
ware protocol (e.g. ISOStart).
Network
Address
IP-Address
192.168.10.10
Subnet-Mask
255.255.255.0
Port
10001
DHCP
OFF
Table 9: Standard factory configuration of the Ethernet connection
Note:
The reader provides a DHCP able TCP/IP interface.
A shielded twisted pair STP CAT5 cable must be used.
USB –Interface X3 (Host communication)
There is a USB-socket X3 on board for the connection of the USB-Interface. The pinout is stand-
ardized. The data rate is reduced to 12 Mbit (USB full speed). A standard USB-cable can be used.
Note:
The length of the USB-cable can be a max. of 5 meter. It isn’t allowed to use longer cables!
Figure 5: USB interface for the host communication

Identification
Installation
ID ISC.MR102
FEIG ELECTRONIC GmbH
Page 15 of 26
M01210-6e-ID.doc
Control and display elements LED
LED
The Reader’s LED can be configured through software.
The following Table 10 shows the default setting.
Abbreviation
Description
LED green
"RUN "
-Turns on when the Reader is ready
LED red
„LABEL“
-Turns on when a transponder is detected.
-Flashes if a RF-Warning appears (red –green alternating
with 8Hz)
(Temperature alarm, short circuit on antenna output)
LED orange
„INITIALIZING“
- Flashes during Reader initialization after power-up.
Table 10: Default configuration of the LEDs

Identification
Installation
ID ISC.MR102
FEIG ELECTRONIC GmbH
Page 16 of 26
M01210-6e-ID.doc
Technical Data
Mechanical Data
Housing
ABS plastic
Enclosed
Dimensions (W x H x D)
85 x 145 x 27 mm / 3,35 x 5,71 x 1,06 in.
Weight
200 g / 0,44 lbs
Degree of Protection
IP 30
Color
similar RAL 9018 (papyrus white)
Electrical Data
Supply voltage
–ID ISC.MR102-A/-B/-USB
–ID ISC.MR102-PoE
12 …24V DC/
12 …24V DC/ or PoE
Power consumption
max. 9 W
Operating frequency
13,56 MHz
Transmitting power
1,2 W ± 1 dB
Antenna connection
SMA female (50)
Antenna DC voltage
7,5V DC ± 1V (5mA) on antenna output
(e.g. for support of external LED)
Interfaces
–ID ISC.MR102-A
–ID ISC.MR102-PoE
–ID ISC.MR102-USB
RS232
Ethernet (TCP/IP)
USB 2.0
Features
- Short circuit detection (antenna)
- Temperature control
- Support of external multiplexer
ID ISC.ANT.MUX (in Host Mode)

Identification
Installation
ID ISC.MR102
FEIG ELECTRONIC GmbH
Page 17 of 26
M01210-6e-ID.doc
Functional Properties
Protocol Modes
- FEIG ISO HOST
- Scan Mode
Supported transponders
-ISO15693, ISO18000-3 Mode 1
(EM HF ISO Chips, Fujitsu HF ISO Chips,
KSW Sensor Chips, IDS Sensor Chips,
Infineon my-d, NXP I-Code, STM LRI ISO
Chips, TI Tag-it)
-NXP I Code 1
-ISO18000-3M3 (Upgrade Code required)
Address setting for interface
Software (0- 254 Addresses)
Visual indicators
1 LED (multicolor –red / green)
Ambient Conditions
Temperature range
- Operation
- Storage
-25°C to +55°C / -13°F to +131°F
-25°C to +45°C / -13°F to +113°F (-PoE)
-25°C to +85°C / -13°F to +185°F
Humidity
5 –95% non condensing
Vibration
EN 60068-2-6
10 Hz to 150 Hz :0,075 mm / 1 g
Shock
EN 60068-2-27
Acceleration : 30 g
Applicable Norms
Radio approval
- Europe
- USA
- Canada
EN 300 330
FCC 47 CFR Part 15
IC RSS-GEN, RSS-210
EMC
EN 300 489
Safety
- Low-Voltage
- Human Exposure
UL 60950-1
EN 50364

Identification
Installation
ID ISC.MR102
FEIG ELECTRONIC GmbH
Page 18 of 26
M01210-6e-ID.doc
Radio Approvals
Europe (CE)
Hereby, FEIG ELECTRONIC GmbH declares that the radio equipment type ID CPR74 is in com-
pliance with Directive 2014/53/EU.
The full text of the EU declaration of conformity is available at the following internet address:
http://www.feig.de/en/downloads-support/declarations-of-conformity.html
Performance Classification according to ETSI EN 301 489: Class 2

Identification
Installation
ID ISC.MR102
FEIG ELECTRONIC GmbH
Page 19 of 26
M01210-6e-ID.doc
Europe (CE)

Identification
Installation
ID ISC.MR102
FEIG ELECTRONIC GmbH
Page 20 of 26
M01210-6e-ID.doc
USA (FCC) and Canada (IC)
Product names:
ID ISC.MR102-A, ID ISC.MRM102-A, ID ISC.MR102-B, ID
ISC.MR102-USB, ID ISC.MRM102-USB, ID ISC.MR102-PoE
Reader name:
ID ISC.MR102
FCC ID:
IC:
PJMMR102
6633A-MR102
Notice for USA and
Canada
This device complies with Part 15 of the FCC Rules and with
RSS-210 of Industry Canada.
Operation is subject to the following two conditions.
(1) this device may not cause harmful interference, and
(2) this device must accept any interference received,
including interference that may cause undesired operation.
Unauthorized modifications may void the authority granted under
Federal communications Commission Rules permitting the operation
of this device.
This equipment has been tested and found to comply with the limits for
a Class A digital device, pursuant to Part 15 of the FCC Rules. These
limits are designed to provide reasonable protection against harmful
interference when the equipment is operated in a commercial
environment. This equipment generates, uses, and can radiate radio
frequency energy and, if not installed and used in accordance with the
instruction manual, may cause harmful interference to radio
communications. Operation of this equipment in a residential area is
likely to cause harmful interference in which case the user will be
required to correct the interference at his own expense.
Le présent appareil est conforme aux CNR d'Industrie Canada appli-
cables aux appareils radio exempts de licence. L'exploitation est auto-
risée aux deux conditions suivantes :
(1) l'appareil ne doit pas produire de brouillage, et
(2) l'utilisateur de l'appareil doit accepter tout brouillage radioélectrique
subi, même si le brouillage est susceptible d'en compromettre le fonc-
tionnement.
Warning: Changes or modification made to this equipment not expressly approved by
FEIG ELECTRONIC GmbH may void the FCC authorization to operate this equipment.
Other manuals for ID ISC.MR102
1
This manual suits for next models
5
Table of contents
Other Feig Electronic IP Access Controllers manuals