Ferroli CONNECT User manual

cod. 3541S180 - Rev. 04 - 09/2019

28
EN
cod. 3541S180 - Rev. 04 - 09/2019
1. Introduction.................................................................................................... 29
2. General safety rules....................................................................................... 29
3. Control class according to ErP regulations................................................ 29
4. For the installer.............................................................................................. 30
4.1 Contents ...................................................................................................... 30
4.2 Installing the receiver................................................................................... 31
4.3 Thermostat installation................................................................................. 33
4.4 Thermostat support assembly ..................................................................... 34
5. For the end user............................................................................................. 35
5.1 Buttons and Icons........................................................................................ 35
5.2 Functional diagram ...................................................................................... 37
5.3 System configuration ................................................................................... 38
5.3.1 Creating the account........................................................................... 38
5.4 RF configuration (Receiver - Thermostat) ................................................... 38
5.5 Wi-Fi configuration (Receiver-Router) ......................................................... 39
5.6 APP ........................................................................................... 40
5.6.1 Manual mode ...................................................................................... 43
5.6.2 Weekly programming mode ................................................................ 44
5.6.3 Vacation mode .................................................................................... 48
5.6.4 Thermostat mode off........................................................................... 48
5.7 Thermostat................................................................................................... 49
5.7.1 Basic operations.................................................................................. 49
5.8 Receiver....................................................................................................... 52
................................................................................ 52

29
EN
cod. 3541S180 - Rev. 04 - 09/2019
1.
Dear customer, thank you for choosing the COИИECT smart thermostat.
It will allow you to accurately control the room temperature and, thanks to Wi-Fi connec-
tivity, can be controlled remotely via the dedicated APP.
This manual is intended for installers and end users.
The main component of the system is the programmable thermostat that can manage
the time programs set by the APP, measure the zone temperature and send on/off com-
mands to the remote control unit, connected directly to the boiler.
2.
• Read the instructions in this manual carefully
• After installation, inform the user about the device’s functions, and giving the user this
booklet to be kept carefully as an integral part of the product and subsequently used
for future reference
• Installation and maintenance must be carried out by qualied personnel, according to
the rules in force and the manufacturer's instructions. Do not perform any operation
on the sealed control parts.
• Remove the electrical power supply before cleaning.
• Do not place the device near heat sources.
• Keep out of the reach of children
3.
With reference to the applicable regulation (EU) No. 811/2013, the data shown in the
table can be used to complete the labeling of heating units.
Possible combinations with COИИECT, related conguration classes and energy contri-
bution to the system.

30
EN
cod. 3541S180 - Rev. 04 - 09/2019
Boiler type
Class and
contribution
Boiler with fixed flow
temperature (On-Off) On-Off type I = 1%
Boiler with variable flow
temperature (set point
with communication bus)
Connection via communication bus. Flow set point
calculated according to room temperature V = 3%
Connection via communication bus. Flow set point
calculated according to the room and outdoor tem-
perature.
VI = 4%
Connection via communication bus. Flow set point
calculated according to at least 3 different ambient
temperatures (at least 3 thermostats and 3 zone valves
required)
VIII = 5%
4.
4.1 Contents
The box includes the following parts:
Transmitter
programmable thermostat
Receiver
Manual

31
EN
cod. 3541S180 - Rev. 04 - 09/2019
USB cable Power supply AAA type batteries
Table support Accessories
4.2 Installing the receiver
To protect the device, remove the power supply from the boiler before mak-
ing the connection. The operation must be carried out by qualied personnel.
The receiver can work with the OpenTherm protocol or with the On-Off contact.

32
EN
cod. 3541S180 - Rev. 04 - 09/2019
Use the magnetic plate or the double-sided adhesive (supplied with the accessories) to
place the receiver in the best position according to the quality of the surface, or use the
screws to secure it directly to the wall.
The gateway must be installed inside the building and should not be shielded by any
metal enclosures.
connect the two terminals of the receiver with label -
Bus to the boiler that supports the OpenTherm protocol. In this case, more information is
available on boiler status (see “5.7.1 Basic operations” on page 49).
connect the two terminals of the receiver with label ON/OFF to
boilers that do not have the OpenTherm communication protocol.
Once powered, the LEDs ash briey.

33
EN
cod. 3541S180 - Rev. 04 - 09/2019
4.3
Separate COИИECT from the base g. 2.
Secure the base using the screws provided g. 3.
In case of thermostat directly connected to the boiler or to a zone valve, the cables must
be connected in the appropriate terminal g. 4.
Insert two 1.5V AAA batteries g. 5.
Hook COИИECT on the base g. 6.

34
EN
cod. 3541S180 - Rev. 04 - 09/2019
4.4
7
4.3 Installazione termostato
Inserire 2 batterie da 1,5V tipo AAA.
4.4 Montaggio supporto termostato
g. 2 -

35
EN
cod. 3541S180 - Rev. 04 - 09/2019
5.
5.1 Buttons and Icons
A description of the symbols on the display and the meaning of the buttons is given below.
Icon
Heating
DHW (domestic hot water)
Flame
On / Off
AUTO mode
MANUAL mode
VACATION mode
Icon
Wireless
WiFi
Low battery level
Temperature and time
mode/save/exit
increase
decrease
set
LED button

36
EN
cod. 3541S180 - Rev. 04 - 09/2019
Battery: The icon on the screen is activated when the battery level is too low.
»Thermostat connected to an on-off boiler, the icon indicates request status.
»Thermostat connected to an OpenTherm boiler, the icon indicates burner status.
Note At rst activation the thermostat is congured automatically in On-Off wire
connection mode.
When the thermostat and the WiFi receiver are connected to the wireless network,
the thermostat automatically switches to RF On-Off.mode.
When the WiFi receiver is connected to an OpenTherm boiler, the thermostat auto-
matically switches to RF OpenTherm mode.
If the thermostat has been congured as RF (on-off or OpenTherm) it does not
automatically switch to on-off wire mode. This can only be done by removing and
putting back the batteries.
: in manual or automatic mode, the icon indicates that the appliance is active.
Note: The icon is only present in the case of RF connection with OpenTherm boilers.
: the icon indicates that heating is active.
Note: The icon is only present in the case of RF connection with OpenTherm boilers.
: the room temperature or errors are displayed:
E82: RF communication error
E83: OpenTherm communication error
Other manuals for CONNECT
3
Table of contents
Other Ferroli Control Unit manuals
Popular Control Unit manuals by other brands

Festo
Festo Compact Performance CP-FB6-E Brief description

Elo TouchSystems
Elo TouchSystems DMS-SA19P-EXTME Quick installation guide

JS Automation
JS Automation MPC3034A user manual

JAUDT
JAUDT SW GII 6406 Series Translation of the original operating instructions

Spektrum
Spektrum Air Module System manual

BOC Edwards
BOC Edwards Q Series instruction manual

KHADAS
KHADAS BT Magic quick start

Etherma
Etherma eNEXHO-IL Assembly and operating instructions

PMFoundations
PMFoundations Attenuverter Assembly guide

GEA
GEA VARIVENT Operating instruction

Walther Systemtechnik
Walther Systemtechnik VMS-05 Assembly instructions

Altronix
Altronix LINQ8PD Installation and programming manual