PORT ASSEMBLY/FIBER TERMINATION
A) Insure that the total fiber count of all fiber
tubings is 450 or less. If you have more than
450 individual fibers, you will need a second
illuminator. The maximum capacity of the
6004 series port is 450 fibers.
B) Insert the proper size tip into the port and
twist with pliers to lock (fig. 1).
C) Strip back all fiber casings no less than 4
inches (fig. 2). Take care not to nick the fibers.
D) Insert the bare fibers into the port so ALL
fibers protrude past the port tip (fig 3). Tighten
the port compression nut down on the fiber
casing (fig 4).
E) IMPORTANT: If the port tip is not completely
full, insert scrap individual fibers into the tip
until it is completely full (fig. 5). This will keep
the lit fibers perpendicular to the lamp, and
prevent the fibers from overheating.
F) Plug in the hot knife (p/n FS-118) and allow it
to heat up. Apply firm downward pressure on
the fibers, with the blade touching the port tip
at a slight angle (fig 6). Do not saw at the fibers.
Allow the heat of the knife to slowly trim the
fibers. Ease the pressure as the knife almost
completes the cut. Unplug the hot knife and
place it in a safe place to cool.