79-15217-00 REV. A www.fiberstars.com Page 2 of 7
CAREFULLY READ AND FOLLOW ALL SAFETY
INSTRUCTIONS IN THIS MANUAL AND ON THE LIGHT
AND ASSOCIATED EQUIPMENT.
HAZARDOUS VOLTAGE Incorrectly installed equipment may fail, causing severe injury or property
damage.
Have a certified electrician perform all tests before operating equipment.
To prevent the risk of damage or injury, do not operate the light out of water for more then 15 minutes.
Allow the light to cool down before installing underwater.
ATTENTION
Fiberstars JAZZ Series Wet-Niche Lighting Fixtures for Swimming pools are now ETL Classified for use with the
following manufactures Wet-Niches for use in new Pool construction. PENTAIR, (American) model no. 79206700
(ABS), model no. 7821XXXX (S/S), 7823XXXX (S/S), model no. 620004 (ABS) HAYWARD, model no. SP0607U
(ABS, Vinyl) SP0600U (ABS, Concrete)
ETL Classification Report No. 3040481
Risk of electrical shock. Before removing fixture from pool wall, ALWAYS TURN OFF THE
POWER at the breaker.
Install this light and light niche in accordance with Article 680 of the National Electrical Code (NEC), in
the United States.
Install an approved Ground Fault Circuit Interrupter in the electrical circuit for this light.
All devices in the system must be directly grounded to a positive electrical ground. All devices in the
system must meet all applicable code requirements for bonding.
Operating pool light at a reduced voltage will diminish the lighting of your pool during nighttime use.
Failure to provide adequate lighting may result in swimming and diving hazards which can cause severe
injury or death

79-15217-00 REV. A www.fiberstars.com Page 3 of 7
Figure 1
Install fixture in a vertical pool or spa wall – not in floor. Failure to install the fixture properly could result in personal
injury and/or property damage.
Except when the fixture is installed in an area of the swimming pool that is not used for swimming and the lens is
adequately guarded to keep any person from contacting it, the fixture shall be installed in or on the wall of the pool with
the top of the lens not less then 18 in. below the normal water level of the pool; see Figure 1.
The junction box must be located:
•At least 4’ from the perimeter of the pool (unless separated from the pool by a solid fence, wall or other
permanent structure,
•At least 8” above maximum water level,
•At least 4” above the deck or ground level.
Junction boxes should be located off the walkway around the pool and given additional protection by installing them next
to a fence, building, or other permanent structure. Make sure that the installation is in compliance with local codes, and
the NEC.
A Ground Fault Circuit Interrupter (GFCI) and an appropriately rated circuit breaker shall be installed in the branch
circuit supplying power to fixtures so that there is no shock hazard during re-lamping.
Lamp Housing Installation
Glass breakage hazard. Do not push off from the poolside against the light.
NOTE: For the J400 3 wires must be supplied to the junction box from the power supply.
Light Fixture Installation
1. Before installing light fixture, make sure power to light is off.
2. Feed cord through niche and conduit, while light fixture is on deck area right above the niche. Feed cord to
junction box leaving enough cord, about 3’ to allow fixture to be placed on deck to allow relamping.
3. Make connections in the junction box.

79-15217-00 REV. A www.fiberstars.com Page 4 of 7
4. Insert cord into the niche and place the lamp housing in the niche. Be sure that the locator tab on the bottom of
the lamp housing is in the notch at the bottom of the niche.
5. Insert the top screw into top hole on niche and tighten.
MAINTENANCE
Hazardous voltage.
Electrical shock hazard. Before removing fixture from pool wall, ALWAYS TURN OFF THE POWER
at the breaker. Installation and maintenance of this circuit, the light, light niche, and any other accessories attached to this
circuit must be performed by a licensed electrician. The complete electrical system must be installed, tested, and
approved by a licensed electrician before it is placed in operation.
Risk of cuts, burns, and electrical shock. Avoid direct impacts on glass lens. Do not install damaged or
broken lens.
1. Be sure that the power is off. Allow the lamp to cool before re-lamping.
2. Loosen the captive leader screw from the top of the fixture trim ring.
NOTICE: The screw in the trim rim may be recessed.
3. Remove the lamp housing and place on the pool deck.
4. Remove screw from clamp.
5. Replace gasket. To reassemble the lens assembly to the lamp housing, reverse the disassembly process. Be sure
that the lamp housing is clean, dry, and free of all traces of moisture, before sealing the fixture.
6. Insert cord into niche and place the lamp housing back in the niche. Be sure to align the locator tab at the bottom
of the lamp housing with the notch in the bottom of the niche.
7. Fasten the lamp housing into the niche using the captive leader screw at the top of the trim ring.
Risk of Electrical Shock or Electrocution.
This fixture must be properly installed in accordance with the National Electrical Code and all applicable local
codes and ordinances by a certified or licensed Electrician. Failure to do so may result in serious injury to
occupants, installers, or cause property damage due to the resulting electrical hazards. Read and follow all
instructions.
Volt and Amp rating for the J400 is as follows, 120 Volts, 84 Watts max., 2.0 Amps
Control Options for the J400.
NOTE: Metal Halide is not dimmable!
A. Switch Controlled.
1. The J400 Jazz light is controlled with one switch.
B. Jandy RS Controlled or comparable control system.
1. The J400 Jazz requires one NON -Dimming relay.

79-15217-00 REV. A www.fiberstars.com Page 5 of 7
C. SPECIAL NOTE FOR X-10 CONTROL
The lowest possible signal that can make a module respond properly is 150mV. Please refer to
the X-10 installation manual. Contact X10PRO for troubleshooting operation.
D. WPC family of controls
Refer to the WPC Installation manual for proper wiring instructions of the Jazz pool light to
the WPC control system.
Section V. Replacing lamp only, see Figure 2.
Risk of Electrical Shock or Electrocution.
Always disconnect the power to the pool light at the circuit breaker before servicing the light. Failure to do so
could result in death or serious injury to serviceman, pool users or others due to electrical shock.
1. Turn off main electrical switch or circuit breaker, as well as the switch, which operates the underwater light, itself.
2. You will need to get the following items.
a. Jazz replacement lamp, J20-4000 (Includes lens gasket)
Always install a new lens gasket (part number J30-7000) whenever disassembling the light. Failure to do
so may permit water to leak into the assembly which could cause:
(a) an electrical hazard resulting in death or serious injury to pool users, installers, or others due to
electrical shock, or
(b) breakage of the lamp or lens, which likewise could result in serious injury to pool users, installers, or
bystanders, or in damage to property.
3. To remove light assembly, remove the special pilot screw at
top of face ring, remove light assembly from niche, and
gently place assembly on deck. You are not required to drain
down the pool.
Jazz Light is heavy. Use caution when removing and
installing into the pool niche. Do not drop; this may
damage the light fixture.
Be sure to keep the special pilot screw from this
underwater light. This screw mounts and electrically
grounds the housing securely to the mounting ring
and wet niche. Failure to use the screw provided
could create an electrical hazard, which could result
in death or serious injury to pool users, installers or
others due to electrical shock.
4. Disassemble light fixture and remove bulb.
a. Disassemble fixture by removing outer clamp ring and lens.
FIG. 2

79-15217-00 REV. A www.fiberstars.com Page 6 of 7
b. Using a small Phillips screwdriver, remove the two screws holding the lamp assembly and the three screws
holding the lamp bracket assembly and hot mirror and place in a secure location, see Figure 3. Do not
remove any screws other than the ones specified in Figure 2.
c. Disconnect lamp at plug, see Figure 2.
Be sure the power is OFF before installing or removing lamp. Allow the lamp to cool before relamping.
This light fixture uses a Metal Halide lamp. Use care when replacing lamp not to touch the lamp or
reflector. Handle only the lamp bracket. Failure to do so may severely reduce the lamp life.
5. Install the new lamp
a. Replace the lamp assembly – noting the side the screw holes are on – assembly goes together only one way.
b. Reassemble lamp assembly by following steps 1 thru 5 in reverse order.
5. Remove old gasket from lens and discard it.
6. Install new gasket during reassembly of light, Fiberstars part number J30-7000.
NOTE: DO NOT USE ANY LUBRICANTS WHEN INSTALLING THE LENS GASKET!
To prevent the risk of damage or injury do not operate fixture on the deck of Pool or Spa for more than 15
minutes. Allow fixture to cool down before installation.
8. Align the letter “E” of the word before on the surface of the lens with the pilot screw hole on the face ring for
proper lens orientation.
9. Secure ring to light fixture. See Section VI. Stainless Steel Face Ring Assembly Instructions.
10. Replace light assembly into niche and tighten special pilot screw.
Use only the special pilot screw provided with this underwater light. This screw mounts and electrically
grounds the housing securely to the mounting dng and wet niche. Failure to use the screw provided could
create an electrical hazard, which could result in death or serious injury to pool users, installers or others
due to electrical shock.
Section VI. Stainless Steel Face Ring Assembly Instructions.
Replace lens gasket. A NEW LENS GASKET MUST BE USED EACH TIME THE LIGHT IS REASSEMBLED.
NOTE: DO NOT USE ANY LUBRICANTS WHEN INSTALLING THE LENS GASKET!
1. With the light resting on its base, place lens/gasket assembly on light fixture and position the face ring so the
pilot screw on the face ring aligns with the letter “E” of the word “BEFORE” on the surface of the lens.
2. Install the compression clamp over the lens, gasket, and base assembly. Tighten the screw and nut until the
distance between the ends of the clamp equals 3/8 – 1/2 inch.

79-15217-00 REV. A www.fiberstars.com Page 7 of 7
Item
No. Part No. Description
1 J20-2000 Lamp Kit, 50W Metal Halide
(Includes replacement gasket #7)
2 J30-3000 Pilot Screw, with captive neoprene washer
3 J30-4000 Face ring, Stainless Steel
4 J30-5000 Compression Clamp
5 J30-6000 Lens, Fiberstars, 8-3/8 in. dia., tempered
6 J30-7000 Gasket, Lens
SAVE THESE INSTRUCTIONS.
6
2
4
3
5
1
Table of contents
Other Fiberstars Light Fixture manuals
Popular Light Fixture manuals by other brands

ADJ
ADJ CRAZY 8 User instructions

Larson Electronics
Larson Electronics EPL-AMB-150LED-200 instruction manual

Red Arrow Trading
Red Arrow Trading LF292LED-IP installation instructions

Professional Entertainment Technology
Professional Entertainment Technology StairVille MH-360 owner's manual

ViSAGE
ViSAGE VIS0481 operating instructions

Wetelux
Wetelux 84 35 74 instruction manual