FingerTec i-Kiosk 100 Plus User manual

i-Kiosk 100 Plus
4 feet / 1.2 meter
(recommended)
Fingerprint Color Multimedia for Time Attendance &
Door Access Control System
Step 1
Determine the Location and Positioning
of the Installation
• Avoid installing the terminals in locations that has contact with
a strong light source (e.g direct sunlight, spotlight, fluorescent
light, etc)
• Avoid installing the terminals in locations prone to high moisture
or condensation levels in the air
• The recommended installation height of the terminal from the
ground is 1.2 meter.
Step 2
Mounting Terminals
• After measuring the height accordingly and make relevant marking
on the wall, drill the screws into the wall to secure the back plate.
• Attach the terminal to the back plate and tighten the screws. Refer to
Appendix II for dimensions and measurements of installation.
Step 3
Wiring for Power Supply
i-Kiosk 100 Plus comes with a special key to unlock ports to power
and door access as shown in the diagram marked B. There are two
ways to connect the power to i-Kiosk 100 Plus.
1. Use the power adapter provided in the package and in-
sert the power adapter to the port marked A in the diagram.
2. Use power cables (black and red) to connect to a linear
power supply with specifications of 12VDC 3A. (Marked B)
Installation Guide
© 2015 Timetec Computing Sdn Bhd. All rights reserved.• 022015
TCP/IP PORT (LAN) USB PORT
RS232/RS485 SERIAL
CABLE PORT
USB Port
POWER ADAPTER PORT (A)
POWER CABLE PORT (B)
BEL+
BEL-
BEEP
GLED
RLED
INWD0
INWD1
TCP / IP
RJ-6
RJ-3
RJ-2
RJ-1
TCP/IP
RS232
RS485
485B
485A
GND
TXD
RXD
GND
WD1
WD2
485B
485A
485B
485A
485B
485A
GND
+12V
D
O
O
R
L
O
C
K
T
I
M
E
R
RX+
RX-
RX+
RX-
Step 4
Setting Up Data Communication
(Skip this step if you are using USB ash disk to transfer data)
TCP/IP – LAN Connection
For TCP/IP connection, plug the special RJ45 jack into the TCP/IP
(LAN) Port of the terminal. Connect the other end (normal RJ45
jack) to the local area network hub or a PC. Configure the device
ID, IP address, subnet mask and Gateway in the terminal (refer to
the hardware user manual for details).
RS232 – Serial Port Connection
Plug the communication jack that is provided in the package to
connect to the communication port of the terminal. Select wires
with label RX, TX and GND, and connect the other end of these
wires to a DB9 female connector. Configure the device ID and
baudrate of the terminal (refer to the hardware user manual for
details). Use the normal RS232 cable to plug into the RS232 port
of the terminal.
RS485 – Serial Port Connection
Plug the communication jack that is provided in the package to
connect to the communication port of the terminal. Select wires
with label RS485+, RS485- and GND, and connect the other end
of these wires to an RS232/485 data converter. Connect the other
end of the data converter to a DB9 female connector. Configure
the device ID and baudrate of the terminal (refer to the hardware
user manual for details).
Step 5
Finalizing the Installation
1. Check that all cable connections are done correctly.
2. Attach the terminal to the corresponding back plates and
tighten the screws to secure the terminal on the wall.
3. Switch on the power to the terminal.
4. Start using the terminal.
Other Accessories
FingerTec offers complementing accessories which can be used with
your terminals. These optional accessories are available at
http://accessory.fingertec.com
AdapTec AC
AdapTec AC
The AdapTec AC is a 12VDC power supply inclusive of a 110~240VAC
switching linear power. The AdapTec supplies 12VDC power to the
FingerTec terminal and door lock system as well as charges a 12VDC
7.0Ah backup battery simultaneously. During an event of a power fail-
ure, the back up battery automatically provides power to the terminal
and maintains the door lock system. The AdapTec AC also prevents a
secured door from being opened if it has been tampered with.
Enclosures
An acrylic-made enclosure that protects your terminal from the risk of
meddling by unauthorized individuals. Our custom made enclosure
are specially designed to fit your terminal perfectly with specific open-
ings for fingerprint scanner and buttons. Our enclosure can be used to
mitigate surrounding mild environmental hazards and help lengthen
the lifespan of the terminals. However, do note that the enclosure is
not dust-resistant and waterproof if subjected to extreme weather
conditions.
Door Lock Accessories
FingerTec offers various door locks accessories to complement
FingerTec door access product range.
3rd party
controller with
26-bits wiegand
input
RS232
cable
1. RS485 Single Connection
2. RS485 Network Connection
RS232/RS485
Data Converter
RS232/RS485
Data Converter
Wiegand OUT
Door Lock connector.
Refer to Appendix I
DC12V3A
Power Supply
3rd party
controller with
26-bits wiegand
output
Wiegand
IN
* Use either power input
NO1
NC1
COM1
NO2
COM2
NC2
SEN
GND
BUT
Bell+
Bell-
NC2
COM2
NO2
NC1
COM1
NO1
BUT
GND
SEN
GND
+12V
+
_
2
3
A
C
NC2
COM2
NO2
NC1
COM1
NO1
BUT
GND
SEN
GND
+12V
+
_
1
3
B
D
NC2
COM2
NO2
NC1
COM1
NO1
BUT
GND
SEN
GND
+12V
BEEL+
BEEL-
BEEP
GLED
RLED
INWD0
INWD1
Appendix II
Terminal Dimensions and Measurements
Front View of Back Plate
Appendix I
Power Supply & Door Lock System Wiring Diagrams
Diagram 1 • Normally Close (NC)
Diagram 2 • Normally Open (NO)
Diagram 3 • Other Accessories
Door Lock Connectors
EMLock (NC)
Emergency
Break Glass (NC)
Overwrite
Keyswithch (NC)
Push Release Button
DC12V 3A
Power Supply
EMLock (NO)
Emergency
Break Glass (NO)
Overwrite
Keyswithch (NO)
Push Release Button
DC12V 3A
Power Supply
Alarm Device (NC)
dry contact
Door Sensor
Doorbell
DC12V 3A
Power Supply
The terminal will trigger the
alarm output (NO or NC) for the
follow-ing situations:
• Door forced open (A door
sen-sor must first be installed)
• Door open time out (A door
sen-sor must first be installed)
• Terminal has been illegally
dismantled
Door Lock Connectors
WIRING USAGE
PORT
Dry Contact
(independ-ent power supply for
door lock)
• NO type door lock (NO1-COM)
• NC type door lock (NC1-COM)
Power Contact
(using power from terminal to
power on door lock)
• NO type door lock (NO-GND)
• NC type door lock (NC-GND)
Dry Contact
(independ-ent power supply for
door lock)
• NO type door lock (NO1-COM)
• NC type door lock (NC1-COM)
Power Contact
(using power from terminal to
power on door lock)
• COM1 - +12V
Door Sensor
(SEN-GND)
Release button
(BUT-GND)
Door Bell
Alarm System
NO Type – NO2 – COM2
NC Type – NC2- COM2
*Door Sensor, Alarm, Doorbell.
Use either Type NO or Type NC alarm device.
Alarm Device (NO)
dry contact

Other manuals for i-Kiosk 100 Plus

3

Other FingerTec Intercom System manuals

FingerTec Face ID3 User manual

FingerTec

FingerTec Face ID3 User manual

FingerTec Face ID 4 User manual

FingerTec

FingerTec Face ID 4 User manual

FingerTec Face ID3 User manual

FingerTec

FingerTec Face ID3 User manual

FingerTec FaceID 4 User manual

FingerTec

FingerTec FaceID 4 User manual

FingerTec TimeLine 100 User manual

FingerTec

FingerTec TimeLine 100 User manual

Popular Intercom System manuals by other brands

Telex Radiocom BTR-200 Series Service manual

Telex

Telex Radiocom BTR-200 Series Service manual

Aiphone MJ-1AD Installation & operation manual

Aiphone

Aiphone MJ-1AD Installation & operation manual

Dahua VTO1220A user manual

Dahua

Dahua VTO1220A user manual

ACO GLASS-IP-7 Installer manual

ACO

ACO GLASS-IP-7 Installer manual

Futura Digital VDT-DJ4 user manual

Futura Digital

Futura Digital VDT-DJ4 user manual

PACH & COMPANY Aegis 7000 Plus quick guide

PACH & COMPANY

PACH & COMPANY Aegis 7000 Plus quick guide

Rocom ZHeroIP Series Quick starting guide

Rocom

Rocom ZHeroIP Series Quick starting guide

Toa N-XC65-W installation manual

Toa

Toa N-XC65-W installation manual

Albrecht AE 600 BT operating manual

Albrecht

Albrecht AE 600 BT operating manual

Vimar Elvox Giotto 6344 Installer's guide

Vimar

Vimar Elvox Giotto 6344 Installer's guide

Aiphone JA-D installation manual

Aiphone

Aiphone JA-D installation manual

2N IP Safety installation manual

2N

2N IP Safety installation manual

Opus Technologies OP-6507/B user guide

Opus Technologies

Opus Technologies OP-6507/B user guide

golmar 6502/G2+ Installer manual

golmar

golmar 6502/G2+ Installer manual

Sewosy CARE-IN KVA1 installation instructions

Sewosy

Sewosy CARE-IN KVA1 installation instructions

Comelit HFX-7000M Technical manual

Comelit

Comelit HFX-7000M Technical manual

Bticino Video Kit installation manual

Bticino

Bticino Video Kit installation manual

Avidsen LUTA 2+ instructions

Avidsen

Avidsen LUTA 2+ instructions

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.