FireAngel WG-2 User manual

-
Installation Guide
WIRELESS INTERLINK
GATEWAY
Drawing No: GN5520
Revision: 1
Drawn By: D4
Tschaka R-M May 2019
FireAngel Safety Technology Limited. Artwork Information
Ensure that you are printing / manufacturing from the original artwork file and not a preview
CONFIDENTIAL: The information provided in this document is proprietary to Sprue Aegis Plc/FireAngel Safety
Technology Limited and as such should only be used/shared for the exclusive manufacture of those products
specified.
Title/Description:
User Manual
Material:
Refer to MS0032
Used On / Used For:
FP1000W2-R (WG-2R)
Size:
W - 88mm / H - 88mm
Supplier:
FLEX
Print Colours:
CMYK
DE = 0800 3330 5103 / technik@sprue.com
NL = 0800 311 1111 / klantenservice@sprue.com
FR = 0800 940 078 / supporttechnique@sprue.com
WG-2

Make a note of the MAC address prior to permanent installation as you will need
this when activating the Gateway for the first time.
3. Connect Power
cable here
To remove the Gateway from a wall: Insert a small screwdriver into the
hole on the side and use it to slide the Gateway up. The Gateway will lift off the
screws that attach it to the wall.
INSTALLATION INSTRUCTIONS
1. The Gateway is designed to lie flat or be secured to a wall.
2. If required, use the supplied plastic anchors and screws to fit
the Gateway to the wall.
GN5520R1
FireAngel SafetyTechnology Limited
Vanguard Centre, Coventry CV4 7EZ UK
30mm
Drill hole spacing
Mounting on a wall:
Please ensure that
you use the screws
provided, as they
were chosen
specifically for use
with this product.
Model No. WG-2

Make a note of the MAC address prior to permanent installation as you will need
this when activating the Gateway for the first time.
3. Connect Power
cable here
To remove the Gateway from a wall: Insert a small screwdriver into the
hole on the side and use it to slide the Gateway up. The Gateway will lift off the
screws that attach it to the wall.
4. Connect Ethernet
cable here
INSTALLATION INSTRUCTIONS
1. The Gateway is designed to lie flat or be secured to a wall.
2. If required, use the supplied plastic anchors and screws to fit
the Gateway to the wall.
GN5520R1
Mounting on a wall:
Please ensure that
you use the screws
provided, as they
were chosen
specifically for use
with this product.
Use the template
provided (opposite) for
guidance on marking
hole positions. Drill holes
into the wall. Insert the
plastic wall plugs. Screw
in the screws. Ensure
screws are protruding
from the wall by 3mm to
allow the Gateway to slot
onto screws.

SETTING UP YOUR GATEWAY
Follow the set-up instructions at:
www.fireangelconnect.com
Please note: an internet connection is required when setting up an alarm network
for the first time, in conjunction with the Gateway.
The WG-2 Gateway allows for Wi-Safe 2 devices to connect to the
internet.The FireAngelConnect app works in conjunction with the
Gateway to enable real time alerts, networking and testing of your
safety alarm system.
LIMITATIONS
The Wi-Safe 2 protocol is not a life safety
protocol and should not be relied upon
for life safety. If your internet connection
is lost, communication from the WG-2
(i.e. to cloud or mobile devices) may not
be possible. The local Wi-Safe 2 alarm
network will still continue to operate as a
stand-alone system and does not rely on
an internet connection to do so.
WARRANTY
For information on individual alarm warranty
please refer to the main alarm manual.
FireAngel Safety Technology Limited
warrants to the original purchaser that its
enclosed WG-2 to be free from defects
in materials and workmanship under
normal residential use and service for a
period of 2 (two) years from the date of
purchase. Provided it is returned with
proof of purchase date, FireAngel Safety
Technology Limited hereby warrants
that during the 2 (two) year period
commencing from the date of purchase
FireAngel Safety Technology Limited, at
its discretion, agrees to replace the unit
free of charge.

SETTING UP YOUR GATEWAY
Follow the set-up instructions at:
www.fireangelconnect.com
Please note: an internet connection is required when setting up an alarm network
for the first time, in conjunction with the Gateway.
The WG-2 Gateway allows for Wi-Safe 2 devices to connect to the
internet.The FireAngelConnect app works in conjunction with the
Gateway to enable real time alerts, networking and testing of your
safety alarm system.
LIMITATIONS
The Wi-Safe 2 protocol is not a life safety
protocol and should not be relied upon
for life safety. If your internet connection
is lost, communication from the WG-2
(i.e. to cloud or mobile devices) may not
be possible. The local Wi-Safe 2 alarm
network will still continue to operate as a
stand-alone system and does not rely on
an internet connection to do so.
WARRANTY
For information on individual alarm warranty
please refer to the main alarm manual.
FireAngel Safety Technology Limited
warrants to the original purchaser that its
enclosed WG-2 to be free from defects
in materials and workmanship under
normal residential use and service for a
period of 2 (two) years from the date of
purchase. Provided it is returned with
proof of purchase date, FireAngel Safety
Technology Limited hereby warrants
that during the 2 (two) year period
commencing from the date of purchase
FireAngel Safety Technology Limited, at
its discretion, agrees to replace the unit
free of charge.
The warranty on any replacement WG-2,
will last for the remainder of the period
of the original warranty in respect of the
wireless module originally purchased –
that is from the date of original purchase
and not from the date of receipt of the
replacement product.
FireAngel Safety Technology Limited
reserves the right to offer an alternative
product similar to that being replaced if
the original model is no longer available
or in stock. This warranty applies to
the original retail purchaser from the
date of original retail purchase and is
not transferable. Proof of purchase is
required. This warranty does not cover
damage resulting from accident, misuse,
disassembly, abuse or lack of reasonable
care of the product, or applications not in
accordance with the user manual. It does
not cover events and conditions outside
of FireAngel Safety Technology Limited’s
control, such as Acts of God (re, severe
weather etc.). It does not apply to retail
stores, service centres or any distributors
or agents. FireAngel Safety Technology
Limited will not recognise any changes to
this warranty by third parties.
FireAngel Safety Technology Limited
shall not be liable for any incidental or

consequential damages caused by the
breach of any expressed or implied
warranty. Except to the extent prohibited
by applicable law, any implied warranty
of merchantability or tness for a
particular purpose is limited in duration
for 2 (two) years. This warranty does
not affect your statutory rights. Except
for death or personal injury, FireAngel
Safety Technology Limited shall not be
liable for any loss of use, damage, cost
or expense relating to this product or
for any indirect or consequential loss,
damages or costs incurred by you or any
other user of this product.
DISPOSAL
Waste electrical products should not be
disposed of with your other household
waste, but within the waste electronic
and electrical equipment (WEEE)
recycling scheme.
WARNING: Do not attempt to
disassemble. Do not burn or dispose of
in re.
TECHNICAL
SPECIFICATION
The WG-2 Gateway is designed to be
installed in conjunction with Wi-Safe 2
(protocol) compatible devices. For more
information visit:
www.reangelconnect.com
230V Mains Powered, 5V DC, 1A
Independently tested to RF standard:
EN 300 220-2
EN 301 489-3
EN 301 489-1
Max RF power: +10dBm
Frequency 868MHz
Hereby, FireAngel Safety Technology
Limited declares that this product
is in compliance with the essential
requirements and other relevant
provisions of Directive 2014/53/EU.
The declaration of conformity may be
consulted at http://spru.es/WG-2
Manufacturer: FireAngel Safety
Technology Limited, Vanguard Centre, Sir
William Lyons Rd, Coventry, CV4 7EZ, UK

TECHNICAL
SPECIFICATION
The WG-2 Gateway is designed to be
installed in conjunction with Wi-Safe 2
(protocol) compatible devices. For more
information visit:
www.reangelconnect.com
230V Mains Powered, 5V DC, 1A
Independently tested to RF standard:
EN 300 220-2
EN 301 489-3
EN 301 489-1
Max RF power: +10dBm
Frequency 868MHz
Hereby, FireAngel Safety Technology
Limited declares that this product
is in compliance with the essential
requirements and other relevant
provisions of Directive 2014/53/EU.
The declaration of conformity may be
consulted at http://spru.es/WG-2
Manufacturer: FireAngel Safety
Technology Limited, Vanguard Centre, Sir
William Lyons Rd, Coventry, CV4 7EZ, UK

-
For more information visit:
www.fireangelconnect.com
(UK) technicalsupport@fireangeltech.com
(DE) technik@fireangeltech.com
(FR) supporttechnique@fireangeltech.com
(NL) klantenservice@fireangeltech.com
(INT) Internationalsupport@fireangeltech.com
Table of contents
Other FireAngel Gateway manuals