Fisher KEYSTONE 6 User manual

TACTICAL HUB
USER GUIDE

·Up to 100 W of power
·USB 2.0 and SMBus data protocol
·Connects to all Nett Warrior / NATO
STANAG 4695 standard components
EASY CONNECTIVITY & EFFICIENT
DATA & POWER MANAGEMENT
FOR SOLDIER-WORN DIGITAL EQUIPMENT
For full information,
please visit our website:
fischerconnectors.com

1
Technical specifications
CONNECTOR INTERFACE 2
ELECTRICAL 3
ENVIRONMENTAL 4
MATERIAL AND MECHANICAL 5
FIRMWARE 5
DIMENSIONS 6
Electrical architecture
VBATT POWER DISTRIBUTION 7
5 V DC POWER DISTRIBUTION 8
DATA DISTRIBUTION 9
Operating instructions
MOLLE MOUNT 10
POWERING KEYSTONE 6 11
ENABLING THE DATA FLOW 12
Keystone app instructions
LAUNCHING THE KEYSTONE APP 13
KEYSTONE APP OVERVIEW 14
PANsSTATUS 15
EUD STATUS 16
BATT AND RADIO/BATT STATUS 17
MENU 19
ATAK PLUG-IN 20
LIMITATIONS OF USE 21

2
Pre-cabled plug
1Code mark
2
3
4
6
5
FMLB
contact
Code mark
21
6
5
3
4
Pre-cabled receptacle
Pre-cabled plug
1
Code mark
2
3
4
6
5
FMLB
contact
Code mark
21
6
5
3
4
Pre-cabled receptacle
Pin Power ports
(plugs)
PAN/EUD ports
(receptacles)
1
VBATT: [10-20] V DC
5 A max
Power supply input
VBATT: [10-20] V DC
5 A max
Power supply output
2 Ground Ground
3 5 V DC IN* 5 V DC OUT**
4 USB+ / SMBus Data USB+
5 USB- / SMBus Clock USB-
6 NC CC line***
Connector front view
Plug Receptacle
Technical specifications
CONNECTOR INTERFACE
*Only on RADIO/BATT port
**EUD port: INPUT/OUTPUT
***EUD port only

3
EUD / HOST
VBATT output
power
Unregulated
VBATT [10-20] V DC,
up to 5 A
USB power Power delivery,
Charge up to 1.5 A
PAN 1/2/3
VBATT output
power
Unregulated
VBATT [10-20] V DC,
up to 5 A
USB output
power
Regulated 5 V DC,
up to 2 A per port
BAT T VBATT input
power
Unregulated
VBATT [10-20] V DC,
up to 5 A
RADIO/BATT
VBATT input
power
Unregulated
VBATT [10-20] V DC,
up to 5 A
USB input
power
5 V DC power
supply from radio
Communication
protocol
EUD, PANs USB 2.0
B AT T,
RADIO/BATT
USB 2.0 and
SMBus versions
1.0/1.1 compatible
Fault mode
protection
Over current, over voltage,
back-power
ELECTRICAL

4
Temperature
Storage -40 °C to +55 °C
Operating -32 °C to +49 °C
Altitude
Storage Up to +12,192 m
Operating Up to +9,754 m
Rapid
decompression
From +2,438 m
to +12,192 m
Sealing IP68 -2m/24h
Shock 40 G, 11 ms
Vibration 7.7 Grms, 1 h per axis
Weather
condition
Solar radiation, salt atmosphere, sand
and dust, rain and water, fungus
EMI/EMC
CE101, CE102, CS101, CS114, CS115,
CS116, RE101, RE102, RS101,
RS103, CS118 Level IV (ESD)
*Validations performed per MIL-STD-810G and MIL-STD-461G
ENVIRONMENTAL*

5
MATERIAL AND MECHANICAL
FIRMWARE
Housing material Aluminum
Weight 241 g (8.5 oz)
Security
■Only booting signed software –
verified using a SHA256 checksum
and an ECC256 signature
■Software update files are encrypted
using an AES 256 encryption
Certification FIPS 140-2/3 capable

6
(18.8)
(0.74")
(88.6)
(3.49")
(96.2)
(3.79")
(96.2)
(3.79")
(100.6)
(3.96")
(30
1.18")
DIMENSIONS in millimeters / in inches

7
·Wide range of batteries supported, incl. SMBus protocol
·Unregulated VBATT distribution [10-20] V DC
·Dual battery hot-swap functionality
·Electrical fail-safe mechanism on all ports
Electrical architecture
VBATT POWER DISTRIBUTION
5 V DC
OUT
5 V DC OUT
DC/DC
CONVERTER
HOT SWAP
5 V DC
VBATT OUT
VBATT OUT
HOT SWAP
VBATT OUT
USB
HOST
USB DEVICES
HUB USB
USB/
SMBUS
BATTERY POWER IN
BATTERY POWER IN
EUD
5 V DC IN
RADIO
5 V DC IN
PAN 1 PAN 2 PAN 3
BATT
10-20 V DC
RADIO BATT
10-20 V DC
EUD
HOST
PAN 1 PAN 2 PAN 3
BATT
10-20 V DC
RADIO BATT
10-20 V DC
EUD
HOST
PAN 1 PAN 2 PAN 3
BATT
10-20 V DC
RADIO BATT
10-20 V DC
EUD
HOST

8
·Regulated 5 V Bus
·USB-C bidirectional power delivery on EUD port
·Radio 5 V DC power IN functionality on RADIO/BATT port
5 V DC
OUT
5 V DC OUT
DC/DC
CONVERTER
HOT SWAP
5 V DC
VBATT OUT
VBATT OUT
HOT SWAP
VBATT OUT
USB
HOST
USB DEVICES
HUB USB
USB/
SMBUS
BATTERY POWER IN
BATTERY POWER IN
EUD
5 V DC IN
RADIO
5 V DC IN
PAN 1 PAN 2 PAN 3
BATT
10-20 V DC
RADIO BATT
10-20 V DC
EUD
HOST
PAN 1 PAN 2 PAN 3
BATT
10-20 V DC
RADIO BATT
10-20 V DC
EUD
HOST
PAN 1 PAN 2 PAN 3
BATT
10-20 V DC
RADIO BATT
10-20 V DC
EUD
HOST
5 V DC POWER DISTRIBUTION

9
·EUD/HOST USB HUB upstream port
·PANs, BATT and RADIO/BATT USB downstream ports
·Automatic detection between USB and SMBus on BATT
and RADIO/BATT ports
DATA DISTRIBUTION
5 V DC
OUT
5 V DC OUT
DC/DC
CONVERTER
HOT SWAP
5 V DC
VBATT OUT
VBATT OUT
HOT SWAP
VBATT OUT
USB
HOST
USB DEVICES
HUB USB
USB/
SMBUS
BATTERY POWER IN
BATTERY POWER IN EUD
5 V DC IN
RADIO
5 V DC IN
PAN 1 PAN 2 PAN 3
BATT
10-20 V DC
RADIO BATT
10-20 V DC
EUD
HOST
PAN 1 PAN 2 PAN 3
BATT
10-20 V DC
RADIO BATT
10-20 V DC
EUD
HOST
PAN 1 PAN 2 PAN 3
BATT
10-20 V DC
RADIO BATT
10-20 V DC
EUD
HOST

10
The integrated MOLLE mounts
allow the KEYSTONE 6 to be
attached to the soldier’s
vest in all four directions.
Operating instructions
MOLLE MOUNT

11
The KEYSTONE 6 can
be powered by a 10 to
20 V DC power source
on the RADIO/BATT port,
the BATT port
or both.
The Nett Warrior extension
cable can be used to
connect directly to a Nett
Warrior style battery or to a
battery adapter.
POWERING KEYSTONE 6

12
To establish the data flow
within the HUB, a host
device must be connected
to the EUD/HOST port.
Connect the End User
Device (EUD) to the Fischer
Nett Warrior plug to USB
type C cable.
With the Fischer EUD
cable, devices with an
USB-C interface can
leverage the KEYSTONE 6’s
built-in power delivery and
be charged.
NOTE: EUD cables with integrated Power Delivery
functionality are not compatible with KEYSTONE 6.
ENABLING THE DATA FLOW

13
Keystone app instructions
LAUNCHING THE KEYSTONE APP
Press OK to enable communication between the HUB
and the HOST once the EUD is connected.

14
KEYSTONE APP OVERVIEW
Intuitive graphic interface with all essential information
directly accessible on one screen.
·Press for Menu and Settings (refer to p.19)
·The icon indicates the internal microcontroller
temperature
·The KEYSTONE 6 has a self-diagnosis function.
The status ok icon will change to alerts when the
HUB is malfunctioning. Press the alerts icon to list
the dierent problems.
1
1
2
2

15
PANs STATUS
The power bar quickly
indicates the amount of
power consumed on the
PAN. This visual indicator
is completed by a
measurement in Watts.
PAN output status:
·Green light means
power is enabled, no
light means disabled
·The visual dierentiation
between VBATT and 5 V
DC is made by the size
of the indicators
Press the PAN icon to:
·Access the output
control by toggling
the VBATT and 5 V DC
buttons
·Display the voltage and
current measurements
of each output
·Modify the PAN name
by clicking on the text
field
NOTE: 5 V DC can be
disabled without cutting
data communication.

16
EUD STATUS
The KEYSTONE 6’s built-in bidirectional power delivery
function allows the EUD to be charged when the HUB
is powered by an external source, typically a battery,
but in the opposite case, the EUD can power the HUB
with 5 V DC only.
The power meter indicates the sense of the energy flow:
EUD on charge EUD providing power
Press the EUD icon to:
·Display the voltage and
current measurements
of the power lines
·Modify the EUD name
by clicking on the text
field

17
BATT AND RADIO/BATT STATUS
The light gray icon shows
the power source in
use. When it is a smart
battery, in addition to
the state of charge and
the voltage level, the
remaining operating time
is displayed.
The following icon indicates that there is no connection
to any power source on the considered port.
The type of battery is identified by a specific icon:
Smart battery with SMBus Simple DC source

18
BATT AND RADIO/BATT STATUS
Press the BATT or RADIO/BATT icon when connected
to a power source to access the following details:
An alert threshold can be
defined according to the
battery charge level. The
threshold is defined as
follows:
·in % for smart batteries
·in Volts for DC sources
Once reached, the battery
icon turns into orange.
The “Set as source”
button allows the user to
force the system to select
a power supply.
The use default source
button returns to the
default selection logic:
·In case the two
connected power
sources are of the same
nature, the RADIO/BATT
port is the default power
source.
·In case a smart battery
and a simple DC voltage
source are connected,
the simple DC voltage
source is the default
power source.
In all cases, the hot-swap
feature allows to switch
from one power supply
to another without any
power loss.
Table of contents
Other Fisher Switch manuals
Popular Switch manuals by other brands

Avaya
Avaya IP Office IP401 installation manual

D-Link
D-Link DGS-1005D - Switch Quick installation guide

ANTAIRA
ANTAIRA LNX-1202G-SFP Series Quick installation guide

Vixel
Vixel InSpeed 335 Installation & configuration guide

Innovative
Innovative L500 Installation and operating manual

Geostuff
Geostuff RS-96/24 operating manual