FJC Estercool Oil -
#2408 (8 oz)
#2432 (qts)
#2439 (gal)
• For use with R12 &
R134a
• Compatible with
Mineral, Ester,
Paraffin & PAG Oil
• Compatible with all
components in the
system
• Available with or
without dye
FJC Flush Solvent -
#2032 (qts)
#2128 (gal)
• Compatible with R12
& R134a
• Compatible with
Mineral, Ester,
Paraffin, & PAG Oil.
• Environmentally Safe
• Removes
contaminates,
moisture, and acid
FJC PAG Oil -
#2468 (8 oz)
#2472 (qts)
#2475 (gal)
• For use with R12 &
R134a
• Compatible with
Mineral, Ester,
Paraffin & PAG Oil
• Compatible with all
components in the
system
• Available with or
without dye &
viscosities of 46-100
-150
Extreme Cold # 9150 & 9153
• Install in Any
Mobile A/C
Refrigerant
• 2 oz Extreme Cold
A/C Oil Injectors
R12
#2729
R134a
#2734
Flush Coupler # 2770
Use Flush Coupler to capture
flush as it leaves the
component being cleaned
• Install in R134a
Systems Only
• 2 oz R134a + 2
oz Extreme
Cold
Hand Turn Oil & Dye Injector
2 oz
Part # 2732
Instrucons
Mail to: Ship to:
P O Box 499 101 Commercial Dr.
Mt. Mourne, NC 28123 Mooresville, NC 28115
704-664-3587
www.cinc.com
FJC 2 ounce Oil and
Dye Injector
Part # 2732
WARNING: ALWAYS USE SPLASH
GOGGLES WHEN OPERATING THIS TOOL.
Operating Instructions:
For R12 Systems:
1. Remove cap with hose.
2. Unscrew handle of injector counterclockwise until inside
edge of handle lines up with line below 2oz / 60ml mark.
3. Fill injector with FJC Universal A/C Dye or FJC PAG or
Ester Oil to bottom of threads inside injector.
4. Screw cap with hose into dye injector. Do Not Over Tighten.
Twist the injector to purge the line of air.
5. Screw hose onto R12 ¼ inch LOW SIDE SERVICE PORT.
WARNING: ONLY CONNECT INJECTOR ONTO LOW
SIDE SERVICE PORT. CONNECTING INJECTOR ON-
TO HIGH SIDE SERVICE PORT CAN CAUSE PER-
SONAL INJURY.
To Inject Oil:
a. Screw handle of injector, clockwise, until handle stops.
Do Not Over Tighten. This injects 2 ounces of oil.
b. Unscrew hose from R12 service port.
To Inject Dye:
a. Screw handle of injector, clockwise, until inside edge of
handle lines up with line under 1 ¾ oz / 52.5ml on
injector. This injects ¼ ounce / 7.5ml of dye.
b. Unscrew hose from R12 service port.
c. To inject dye into next vehicle, screw handle of injector,
clockwise, until inside edge of handle lines up with next
line on injector to inject ¼ ounce / 7.5ml of dye into A/C
Read Carefully Before Using
system.
6. Remove cap with hose and repeat steps 2 through 5.
For R134a Systems:
1. Screw injector hose onto R134a quick coupler.
2. Remove cap with hose.
3. Unscrew handle of injector counterclockwise until inside
edge of handle lines up with line below 2oz / 60ml mark.
4. Fill injector with FJC Universal A/C Dye or FJC PAG or
Ester Oil to bottom of threads inside injector.
5. Screw cap with hose into dye injector. Do Not Over Tighten.
6. Connect R134a quick coupler onto LOW SIDE SERVICE
PORT.
WARNING: ONLY CONNECT INJECTOR ONTO LOW
SIDE SERVICE PORT. CONNECTING INJECTOR ON-
TO HIGH SIDE SERVICE PORT CAN CAUSE PER-
SONAL INJURY.
To Inject Oil:
c. Screw handle of injector, clockwise, until handle stops.
Do Not Over Tighten. This injects 2 ounces of oil.
d. Disconnect R134a quick coupler from low side service
port.
To Inject Dye:
d. Screw handle of injector, clockwise, until inside edge of
handle lines up with line under 1 ¾ oz / 52.5ml on
injector. This injects ¼ ounce / 7.5ml of dye.
e. Disconnect R134a quick coupler from low side service
port.
f. To inject dye into next vehicle, screw handle of injector,
clockwise, until inside edge of handle lines up with next
line on injector to inject ¼ ounce / 7.5ml of dye into A/C
system.
Remove cap with hose and repeat steps 3 through 6.

Popular Laboratory Equipment manuals by other brands

NI PXI-5422 CALIBRATION PROCEDURE

NI

NI PXI-5422 CALIBRATION PROCEDURE

Integra VIAFLO 96 6000 quick start guide

Integra

Integra VIAFLO 96 6000 quick start guide

R-Biopharm RIDA qLine Scan user manual

R-Biopharm

R-Biopharm RIDA qLine Scan user manual

Opsytec Dr. Grobel BS-04 manual

Opsytec Dr. Grobel

Opsytec Dr. Grobel BS-04 manual

Thermo Scientific EA IsoLink IRMS System operating manual

Thermo Scientific

Thermo Scientific EA IsoLink IRMS System operating manual

Bluescience Pro installation instructions

Bluescience

Bluescience Pro installation instructions

Leica CM1520 Instructions for use

Leica

Leica CM1520 Instructions for use

Picotest J2200A user manual

Picotest

Picotest J2200A user manual

IKA RET control-visc operating instructions

IKA

IKA RET control-visc operating instructions

diapath Galileo AUTO 2 Series user manual

diapath

diapath Galileo AUTO 2 Series user manual

Noraxon Ultium EMG System user manual

Noraxon

Noraxon Ultium EMG System user manual

Civco GUS G32-S Operator's manual

Civco

Civco GUS G32-S Operator's manual

Sigma 2-5 Operating	 instruction

Sigma

Sigma 2-5 Operating instruction

Wassermann Polyquick 260 user manual

Wassermann

Wassermann Polyquick 260 user manual

Thermo Scientific TSQ Endura Hardware manual

Thermo Scientific

Thermo Scientific TSQ Endura Hardware manual

LI-COR LI-6400 manual

LI-COR

LI-COR LI-6400 manual

Helmer Scientific QuickThaw DH2 Operation manual

Helmer Scientific

Helmer Scientific QuickThaw DH2 Operation manual

PHYWE 11207-30 quick start guide

PHYWE

PHYWE 11207-30 quick start guide

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.