
CONTENTS
SAFTEY INFO AND WARNINGS.........................................................................................................................................4
FLARE FIREPLACES –FRAMELSS IN EVERY WAY............................................................................................................... 4
SAFETY.............................................................................................................................................................................5
MANUAL MODEL LIST & INFORMATION .........................................................................................................................5
POWER VENTING OVER VIEW .........................................................................................................................................6
POWER VENT DRAWINGS................................................................................................................................................6
HORIZONTAL END OF LINE POWER VENT DRAWING ..................................................................................................... 6
..................................................................................................................................................................................... 7
HORIZONTAL END-OF-LINE POWER VENT FRAMING DIMENSIONS .......................................................................................7
HORIZONTAL POWER VENT PART LIST ...................................................................................................................................8
VERTICAL END OF LINE POWER VENT DRAWING ........................................................................................................... 9
VERTICAL POWER VENT PART LIST ...................................................................................................................................... 11
IN-LINE POWER VENT DRAWING................................................................................................................................. 12
IN-LINE POWER VENT PARTS LIST ........................................................................................................................................ 13
VENT ADAPTER CONVERSION........................................................................................................................................14
CLEARANCES TO POWER VENT......................................................................................................................................17
CLEARANCES TO VENT PIPE........................................................................................................................................... 17
MINIMUM CLEARANCE TO COMBUSTIBLES FROM VERTICAL VENT .............................................................................. 17
MULTIPLE VERTICAL TERMINATION POINTS ................................................................................................................. 18
MULTIPLE HORIZONTAL TERMINATION POINTS............................................................................................................18
VENT TERMINATION CLEARANCES ................................................................................................................................ 19
VENT RESTRICTOR SETUP ..............................................................................................................................................20
VENT RESTRICTOR TROUBLESHOOTING ........................................................................................................................20
POWER VENT ELECTRICAL CONNECTION.......................................................................................................................21
MAXITROL CONNECTIONS.............................................................................................................................................21
FIREPLACE ELECTRICAL DRAWING (WITH POWER VENT-MAXITROL) .......................................................................................... 22
SIT PROFLAME 2 CONNECTIONS....................................................................................................................................23
FIREPLACE ELECTRICAL DRAWING (WITH POWER VENT-SIT PROMFLAME 2) ...............................................................................24
POWER VENT BOARD ELECTRICAL DRAWING................................................................................................................25
STARTING UNIT ............................................................................................................................................................. 25
VENTING........................................................................................................................................................................26
CONNECTING 3X5 PIPE.................................................................................................................................................. 28
REPLACEMENT PARTS....................................................................................................................................................29
APPENDIX...................................................................................................................................................................... 30
YEARLY SERVICE REQUIREMENTS..................................................................................................................................30
PILOT MAINTENANCE................................................................................................................................................. 30