manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. Fluidmaster
  6. •
  7. Toilet
  8. •
  9. Fluidmaster 580AU User manual

Fluidmaster 580AU User manual

Ensure the rubber gasket is on the inside of
the cistern tank. Holding outlet valve in place,
thread large plastic locknut onto threads of
outlet valve. Hand-tighten locknut and use large
adjustable pliers to go 1/2 turn beyond hand
tight. DO NOT OVERTIGHTEN.
Once the old fitting is removed and the tank
has been cleaned, insert the Fluidmaster outlet
valve into position. Note: Position cable
opposite to inlet fill valve and ensure
cable does not interfere with any
moving parts within toilet cistern.
After turning the water off, remove the old
fitting by removing the locking nut under the
toilet tank.
1
4
IMPORTANT: Prior to installation, turn the water off at the wall, flush toilet cistern and mop up the residual water to avoid spillage before
removing the old outlet valve. After removing the old outlet valve, please clean the cistern tank of all dirt and grime, and ensure no debris
is left in the tank.
Select from the following 5 applications the correct mounting method for your toilet cistern and follow the instructions
Button Part
Descriptions
FLUIDMASTER®
580AU CABLE DUAL FLUSH VALVE
INSTALLATION INSTRUCTIONS FOR TOILET CISTERN
PART# 25-1329 Grev 4 09/17
Wall Mount Cisterns: Connect the existing
flush pipe to the base of the outlet valve and
hand tighten the nut (Do not overtighten).
Ensure the flush pipe nut washer is in good
condition.
Button
Big Nut
REMOVE & DISCARD
REMOVE & DISCARD REMOVE & DISCARD
Button Collar
Button Collar
Outer Flange
Outer Flange
Outer Flange
Button
Outer Flange
Button Collar
Big Nut
Small Nut Small Nut
Small Nut
Button Button
Button
Button Collar
Button Collar
Small Nut
Small Nut
Big Nut
Big Nut
REMOVE & DISCARD
Outer Flange
Big Nut
Button Lock
Small Nut
Button Collar
REMOVE & DISCARD
Outer Flange
Big Nut
Application A:
Top Push Button 38mm
Application B:
Top Push Button 48mm
Application C:
Side Push Button
Application D:
Front Push Button
Application E:
16-25mm Hole
4B. Ensure the cable runs smoothly & does not interfere with the workings of the valve.
4C. Slide button lock in; secure button box to button & release to lock.
Button Lock
Button Box
IMPORTANT: DO NOT USE PLUMBER´S PUTTY TO SEAL THIS CABLE DUAL FLUSH VALVE
WM-022481
2
6
The over flow tube height can be adjusted up
and down. Turn the over flow tube to the right
to unlock. Adjust height to suit and turn the
over flow tube to the left to lock. Ensure top of
overflow is 25mm below the CL (Critical Level)
line on the inlet valve. This is to ensure the
correct air gap.
3
7A
A. To adjust FULL VOLUME, first slide small
tab to the unlock position. Push larger tab
upwards for less water and downwards for
more water.
B. To adjust PARTIAL VOLUME, push tab
inwards while sliding tab upwards for less
water and downwards for more water.
PARTIAL
FLUSH
B
FULL
FLUSH
A
LESS
MORE
1
6
LESS
MORE
12
1
5
AB
File Name: 25-1329_Grev4_580AU_Instructions_092817
Printing & Finishing: 4/C Offset
Colors: CMYK DIE
PMS Colors:
DO NOT USE IN-CISTERN DROP-IN TOILET BOWL
CLEANERS CONTAINING BLEACH OR CHLORINE.
Use of such products will: (1) RESULT IN
DAMAGE to Cistern components and MAY CAUSE
FLOODING and PROPERTY DAMAGE and (2) VOID
FLUIDMASTER WARRANTY.
DO NOT overtighten nuts or cistern/bowl may
crack. Always use quality Fluidmaster parts when
installing or repairing. Fluidmaster will not be
responsible or liable for use of non-Fluidmaster
parts during installation or repair.
WARNING
WARRANTY - Our goods come with guarantees that cannot be excluded under the Australian
Consumer Law. You are entitled to a replacement or refund for a major failure and for
compensation for any other reasonably foreseeable loss or damage. You are also entitled to
have the goods repaired or replaced if the goods fail to be of acceptable quality and the failure
does not amount to a major failure.
To present claims under this warrantly, please contact your place of purchase or
contact Fluidmaster Holding Australia Pty Ltd.
Warranty period is two years from date of purchase. Warranty excludes incorrect
installation. Warranty on Replaceable Silicone Outlet Washer is subject to water
conditions and fair wear and tear.
IN NEW ZEALAND Call 09 415 5585
Replacement Silicone
Outlet Washer
Part # 56-01
Wedge Flush Pipe
Washer
Part # 56-02
Flush Pipe
Locking Collar
Part # 56-03
Tank to Bowl Gasket (Foam)
For Close Coupled Only
Part # 56-04
Tank to Bowl Gasket (Rubber)
For Close Coupled Only
Part # 6100
OTHER REPLACEMENT PARTS AVAILABLE SEPARATELY
Maximum water level within the cistern tank must be no higher than 20mm below the top of the outlet valve overflow tube. The overflow tube may be raised or lowered
depending on the maximum required level of water for a full flush, however the overflow height must always be 25mm below the critical level (CL) marked on the Inlet
Valve to ensure an Air Gap. Note: Position cable opposite to inlet fill valve and ensure cable does not interfere with any moving parts within
toilet cistern. TURN ON WATER SUPPLY.
Fill tank with additional 3 litres (6 Litre total),
for 6/3L Flush or Fill Tank with additional 11/2
litres (4.5 Litre total) for 4.5/3L Flush then mark
the top of Water Level. This is your Full Flush,
adjust the Full Flush Tab to set this volume.
(For older 9/4.5L flush toilet cisterns, use 4.5L
to set half flush mark and add 4.5L on top of
half flush volume to achieve 9L full flush volume
mark)
To establish water levels, pour in 3 litres of
water, then press full flush. This will establish
the residual water level mark, then add 3 litres
on top of the residual water and mark the top of
the water level. This is your 3 litre volume.
Adjust half flush tab on the side to flush 3 litres.
Please retain instructions for future reference.
Fluidmaster 580AU Cable Dual Flush Valve Suits Flush Volumes:
4.5 Litre / 3 Litre
6 Litre / 3 Litre
9 Litre / 4.5 Litre
FLUIDMASTER®
580AU CABLE DUAL FLUSH VALVE
INSTALLATION INSTRUCTIONS FOR TOILET CISTERN
Close Coupled Cisterns:
Place rubber gasket on pan
hole and centre the tank onto
the washer. Where required,
place bolts downwards in bolt holes and tighten.
PART# 25-1329 Grev 4 09/17
IMPORTANT: DO NOT USE PLUMBER´S PUTTY TO SEAL THIS CABLE DUAL FLUSH VALVE
7B
NB: Shank length may be cut to
suit Close Coupled Cisterns
89
10
Fluidmaster Holding Australia Pty Ltd
5B/100 New Street
Ringwood, Victoria 3134
Australia
Phone: +61 (03) 8870 2555
Toll Free: 1 800 931 166
Email: salesau@fluidmaster.com
Website: www.Fluidmaster.com.au
File Name: 25-1329_Grev4_580AU_Instructions_092817
Printing & Finishing: 4/C Offset
Colors: CMYK DIE
PMS Colors:

Other Fluidmaster Toilet manuals

Fluidmaster soft spa 9500 User manual

Fluidmaster

Fluidmaster soft spa 9500 User manual

Fluidmaster BETTER THAN WAX 7530P8 User manual

Fluidmaster

Fluidmaster BETTER THAN WAX 7530P8 User manual

Fluidmaster THE EVERYTHING K-400H-038 User manual

Fluidmaster

Fluidmaster THE EVERYTHING K-400H-038 User manual

Popular Toilet manuals by other brands

Laufen ILBAGNOALESSI 82097.6 Installation instruction

Laufen

Laufen ILBAGNOALESSI 82097.6 Installation instruction

Kohler K-4734-NY Installation and care guide

Kohler

Kohler K-4734-NY Installation and care guide

rba The Big John Econo installation instructions

rba

rba The Big John Econo installation instructions

Kohler VEIL K-1381T-S installation instructions

Kohler

Kohler VEIL K-1381T-S installation instructions

Cinderella Urinal installation manual

Cinderella

Cinderella Urinal installation manual

Mirabelle AMBERLEY MIRAM241SWH manual

Mirabelle

Mirabelle AMBERLEY MIRAM241SWH manual

Clesana C1 Series installation instructions

Clesana

Clesana C1 Series installation instructions

Spectrum Brands Pfister Verano VTP-E32W Quick installation guide

Spectrum Brands

Spectrum Brands Pfister Verano VTP-E32W Quick installation guide

Invacare Aquatec 90 Ergo user manual

Invacare

Invacare Aquatec 90 Ergo user manual

Invacare 1300RTS user manual

Invacare

Invacare 1300RTS user manual

Kogan KATOPOTPNKA user guide

Kogan

Kogan KATOPOTPNKA user guide

Enders MOBIL-WC DELUXE Assembly and instruction manual

Enders

Enders MOBIL-WC DELUXE Assembly and instruction manual

Inax ACT-902VN quick start guide

Inax

Inax ACT-902VN quick start guide

Franke CAMPUS CMPX597 Installation and operating instructions

Franke

Franke CAMPUS CMPX597 Installation and operating instructions

TECE TECEone Technical guidelines

TECE

TECE TECEone Technical guidelines

American Standard COMPACT CODIE TF-2407 installation manual

American Standard

American Standard COMPACT CODIE TF-2407 installation manual

URIMAT Trespa 35.001 Installation instruction

URIMAT

URIMAT Trespa 35.001 Installation instruction

TRONE Zendoro ZETBCDER-12.WH instruction manual

TRONE

TRONE Zendoro ZETBCDER-12.WH instruction manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.