FOR-A HVS-GPIO128 User manual

HVS-GPIO128
Interface Extension Unit
1st Edition
OPERATION
MANUAL

2
Precautions
Important Safety Warnings
[Power]
Caution
Operate unit only at the specified supply voltage.
Disconnect the power cord via the power plug only. Do not pull on the cable portion.
Stop
Do not place or drop heavy or sharp-edged objects on the power cord. A damaged
cord can cause fire or electrical shock hazards. Regularly check the power cord for
excessive wear or damage to avoid possible fire / electrical hazards.
Caution
Ensure the power cord is firmly plugged into the AC outlet.
[Grounding]
Caution
Ensure the unit is properly grounded at all times to prevent electrical shock.
Hazard
Do not ground the unit to gas lines, units, or fixtures of an explosive or dangerous
nature.
[Operation]
Hazard
Do not operate the unit under hazardous or potentially explosive atmospheric
conditions. Doing so could result in fire, explosion, or other hazardous results.
Hazard
Do not allow liquids, metal pieces, or other foreign materials to enter the unit. Doing
so could result in fire, other hazards, or a unit malfunction.
If a foreign material does enter the unit, turn the power off and immediately disconnect
the power cord. Remove the material and contact an authorized service representative
if damage has occurred.
[Transportation]
Hazard
Handle with care to avoid impact shock during transit, which may cause malfunction.
When you need to transport the unit, use the original or suitable alternative packing
material.

3
[Circuitry Access]
Do not remove covers, panels, casing, or access the circuitry with power applied to
the unit. Turn the power off and disconnect the power cord prior to removal. Internal
servicing / adjustment of unit should only be performed by qualified personnel.
Stop
Do not touch any parts / circuitry with a high heat factor.
Capacitors can retain enough electric charge to cause mild to serious shock, even after
the power has been disconnected. Capacitors associated with the power supply are
especially hazardous.
Hazard
Unit should not be operated or stored with cover, panels, and / or casing removed.
Operating the unit with circuitry exposed could result in electric shock / fire hazards or
a unit malfunction.
[Potential Hazards]
Caution
If abnormal odors or noises are noticed coming from the unit, immediately turn the
power off and disconnect the power cord to avoid potentially hazardous conditions. If
problems similar to the above occur, contact an authorized service representative
before attempting to operate the unit again.
[Rack Mount Brackets, Ground Terminal, and Rubber Feet]
Caution
To rack-mount or ground the unit, or to install rubber feet, do not use screws or
materials other than those supplied. Doing so may cause damage to the internal
circuits or components of the unit. If you remove the rubber feet that are attached to
the unit, do not reinsert the screws that secure the rubber feet.
[Consumables]
Caution
Consumable items that are used in the unit must be periodically replaced. For further
details on which parts are consumables and when they should be replaced, refer to
the specifications at the end of the Operation Manual. Since the service life of the
consumables varies greatly depending on the environment in which they are used,
such items should be replaced at an early date. For details on replacing consumable
items, contact your dealer.

4
Upon Receipt
HVS-GPI128 units and their accessories are fully inspected and adjusted prior to shipment. Check your
received items against the packing lists below. Check to ensure no damage has occurred during
shipment. If damage has occurred, or items are missing, inform your supplier immediately.
◆HVS-GPIO128 Box
ITEM
QTY
REMARKS
HTG-GPIO128
1
AC adapter
1
DC plug with lock system
Power cord
1
EIA rack mount brackets
1 set
Operation Manual
1
This manual
Option
ITEM
QTY
REMARKS
AC adapter
1
For power redundancy.
◆Items needed to be prepared
ITEM
QTY
REMARKS
LAN cable
1
For HVS-GPIO128 and switcher connection
UTP Category 5e or 6 (straight-through)
Computer
1
For network settings for HVS-GPIO128
LAN cable or
RS-232C cable
1
For network settings for HVS-GPIO128
(See Sec. 4. “Setup Menu.“)
LAN cable: UTP Category 5, 5e or 6 (straight-
through)
RS-232C cable: Crossover cable

5
Table of Contents
1. HVS-GPIO128 Overview......................................................................................................................6
2. Panel Description .................................................................................................................................6
2-1. Front Panel..................................................................................................................................6
2-2. Rear Panel ..................................................................................................................................7
2-3. Interfaces ....................................................................................................................................8
2-3-1. GPI 1-4.................................................................................................................................8
2-3-2. SERIAL1-4........................................................................................................................ 10
2-4. Internal Settings ....................................................................................................................... 11
3. Connecting to the HVS Switcher....................................................................................................... 12
4. Setup Menu ....................................................................................................................................... 13
4-1. If Connecting via LAN .............................................................................................................. 13
4-2. If Connecting via RS-232C ...................................................................................................... 13
4-3. Changing HVS-GPIO128 IP Address ...................................................................................... 14
4-4. Resetting the Setup Menu........................................................................................................ 15
5. Specifications and Dimensions ......................................................................................................... 16
5-1. Unit Specifications.................................................................................................................... 16
5-2. External Dimensions................................................................................................................ 16

6
1. HVS-GPIO128 Overview
The HVS-GPIO128 is a Interface Extension Unit for HVS (Hanabi) Series switchers.
Supported HVS Series switcher
Number of unit connection
HVS-2000
1
An HVS-GPIO128 unit can add the following interfaces to switchers.
Serial port: 9-pin D-sub x 4
Free assignable GPI port: 37-pin D-sub (female, 128 input/output) x 4
2. Panel Description
2-1. Front Panel
No.
Name
Description
A
POWER
Displays the power status.
B
LAN
Displays the connection status between HVS-GPIO128 and
switcher.
Also displays the Flash-writing status.
C
GPI
Lights green when GPI signal is sent or received.
D
SERIAL1-4
Lights green when serial data is sent or received.
E
RESET
Resets HVS-GPIO128.
◆Lit Indications for POWER and LAN indicators
Indication
Indicator
Lit
Green
Flashing
Red
Lit
Orange
Unlit
POWER
Normal
Power alarm
LAN
Normal
(Normal mode)
Flash writing
* Do NOT power off
while it is lit.
Disconnected
A
B
D
E
C
POWER LAN SERIAL
GPI 1 2 3 4 RESET
HVS-GPIO128GPIUNIT

7
2-2. Rear Panel
No.
Name
Description
A
LAN
For switcher (MU) connection via LAN
Ethernet (10/100BASE-TX)
B
SERVICE
For service use (Setup menu settings by serial connection)
C
DC12V IN 1
DC12V IN 2
For 12 VDC power input
D
SERIAL 1
SERIAL 2
SERIAL 3
SERIAL 4
For RS-232C / RS-422 control connection. (*1)
RS-232C or RS-422 can be selected using switches on the
card. (Default: RS-232C)
►See Sec. 2-4. “Internal Settings.”
E
GPI 1(Port 1)
For GPI input/output
(Function (input and output) free assignable, 32 for each)
F
GPI 2(Port 2)
G
GPI 3(Port 3)
H
GPI 4(Port 4)
(*1) Serial interface extension may not be disabled depending on connection circumstances.
Refer to connection device manuals to select RS-232C or RS-422.
A
B
C
D
E
F
G
H
LAN GPI 1 GPI 2 GPI 3 GPI 4 2 - DC12V IN -1
RATING LABEL
SERIALSERVICE 1 2 3 4

8
2-3. Interfaces
2-3-1. GPI 1-4
◆Connector Appearance
37-pin D-sub x 4 ports
Total of 128 GPI connections are provided by 4 ports. (32 x 4)
Both GPI input and output signals can be assigned to each connection (pin). Assignments can
be changed in the switcher menu. See the switcher operation manual for more details.
◆Pin Assignments (GPI 1 default settings)
Pin No.
Signal
Pin No.
Signal
1
GPI_IN / TALLY_OUT 01
20
GPI_IN / TALLY_OUT 20
2
GPI_IN / TALLY_OUT 02
21
GPI_IN / TALLY_OUT 21
3
GPI_IN / TALLY_OUT 03
22
GPI_IN / TALLY_OUT 22
4
GPI_IN / TALLY_OUT 04
23
GPI_IN / TALLY_OUT 23
5
GPI_IN / TALLY_OUT 05
24
GPI_IN / TALLY_OUT 24
6
GPI_IN / TALLY_OUT 06
25
GPI_IN / TALLY_OUT 25
7
GPI_IN / TALLY_OUT 07
26
GPI_IN / TALLY_OUT 26
8
GPI_IN / TALLY_OUT 08
27
GPI_IN / TALLY_OUT 27
9
GPI_IN / TALLY_OUT 09
28
GPI_IN / TALLY_OUT 28
10
GPI_IN / TALLY_OUT 10
29
GPI_IN / TALLY_OUT 29
11
GPI_IN / TALLY_OUT 11
30
GPI_IN / TALLY_OUT 30
12
GPI_IN / TALLY_OUT 12
31
GPI_IN / TALLY_OUT 31
13
GPI_IN / TALLY_OUT 13
32
GPI_IN / TALLY_OUT 32
14
GPI_IN / TALLY_OUT 14
33
Frame ground
15
GPI_IN / TALLY_OUT 15
34
Frame ground
16
GPI_IN / TALLY_OUT 16
35
Frame ground
17
GPI_IN / TALLY_OUT 17
36
+4.8V output
18
GPI_IN / TALLY_OUT 18
37
+4.8V output
19
GPI_IN / TALLY_OUT 19
* Max current (total): 1.5A for +4.8V output pins
* GPI input pulse width: 54 ms or more
* Refer to manuals of connection devices for signal input and output switching and
conditions.

9
◆GPI IN circuit
◆GPI OUT / TALLY OUT circuit
* About 0.9 V when ON
HVS-GPIO128
VCC
VCC
Ext. device
Switch or Relay
HVS-GPIO128
VCC
VCC
Ext. device
Open Collector
Ext. device
Max. 40V
HVS-GPIO128
Max. 100mA
10Ω

10
2-3-2. SERIAL1-4
◆Connector Appearance
9-pin D-sub (male) x 4 ports
◆RS-232C / RS-422 Specifications
Select RS-232C or RS-422 using switches on the card. (Default: RS-232C)
►See Sec. 2-4. “Internal Settings.”
RS-232C Pin Assignments RS-422 Pin Assignments
Pin No.
Signal
Description
Pin No.
Signal
Description
1
NC
N/C
1
FG
Frame Ground
2
RxD
Receive Data
2
T-
Transmit Data (-)
3
TxD
Transmit Data
3
R+
Receive Data (+)
4
DTR
Data Terminal Ready
4
SG
Signal Ground
5
SG
Signal Ground
5
NC
N/C
6
DSR
Data Set Ready
6
SG
Signal Ground
7
RTS
Request To Send
7
T+
Transmit Data (+)
8
CTS
Clear To Send
8
R-
Receive Data (-)
9
NC
N/C
9
FG
Frame Ground
Communication
specifications
Baud rate
19,200, 38,400, 57,600, 115,200 bps
Data
8-bit (fixed)
Parity
Odd, Even or None
Stop parity
1-bit (fixed)
Flow control
None
* SERVICE connector pin assignments are the same as those of RS-232C.

11
2-4. Internal Settings
CAUTION
To prevent injury from electrical shock, power should be OFF and all power cords
disconnected from the unit.
Further note that adjustment and maintenance using internal switches should
only be performed by qualified technical personnel familiar with FOR-A
equipment.
Remove two screws on both sides of the HVS-GPIO128 chassis and open the top cover plate. The
board as shown below will appear.
As factory default, switches on the board are set as shown below. (■indicates switch position.)
◆S4-4 Switch
S4-4
Reset all HVS-GPIO128 settings to default.
(Switch ON -> Power ON -> Power OFF -> Switch OFF)
►See Sec. 4-4 “Resetting the Setup Menu.”
◆S12-S19 Switches
Select RS-232C or RS-422 for each serial port using a switch pair.
S12, S14
SERIAL1 setting
Switch
settings
RS-232C
(Default)
S13, S15
SERIAL2 setting
S16, S18
SERIAL3 setting
RS-422
S17, S19
SERIAL4 setting
◆Other Switches
Do not change settings.
S2, S3
For maintenance use. Do not change.
(See the figure above)
S5, S6, S7,
S8, S9, S10
For maintenance use. Do not change.
S11
For maintenance use. Do not change.
OFF
ON
Front
side
S10
S9
S8
S7
S6
S5
S11
S4
ON
OFF
ON
OFF
S12
S13
S16
S17
S2
S14
S15
S18
S19
S3
422
232C
422
232C
422
232C
422
232C
422
232C
422
232C
422
232C
422
232C
422
232C
422
232C
OFF
ON

12
3. Connecting to the HVS Switcher
(1) If network settings in the system are factory default settings, go to Step (2).
If network settings such as the HVS switcher LAN1 port address are changed from default, refer to
the next chapter and change network settings in the Setup menu to the current ones.
(2) Connect HVS-GPIO128 to the HVS Series switcher (MU) via LAN.
Use a LAN switch to connect HVS-GPIO128 to LAN 1(MAIN) on the switcher.
(3) Connect HVS-GPIO128 to serial control devices.
Use the HVS switcher menu to set up the devices.
(4) Connect HVS-GPIO128 to GPI controllers.
Use the HVS switcher menu to set up the devices.
(5) Use the supplied AC adapters to supply power to HVS-GPIO128.
LAN GPI 1 GPI 2 GPI 3 GPI 4 2 - DC12V IN -1
RATING LABEL
SERIALSERVICE 1 2 3 4
LAN switch
HVS Series MU
LAN 2
(SUB)
HVS-GPIO128
LAN 1
(MAIN)
PC for
HVS-GPIO128
Setup
AC adapter
AC adapter
HVS-2000 (default)
192.168.0.80 / 24
Default:
192.168.0.40 / 24
PC IP address
192.168.0.10 / 24
Serial Controller
(Editor, Video server, etc.)
GPI Controller
RS-232C
RS-232C/RS-422
100BASE-TX

13
4. Setup Menu
Network settings such as IP address setting can be changed in the Setup menu. Prepare a PC to
connect to the HVS-GPIO128 via LAN or RS-232C. Use a terminal software (such as Tera Term) to
communicate with HVS-GPIO128.
4-1. If Connecting via LAN
(1) Change the PC IP address to 192.168.0.10 (Netmask: 255.255.255.0).
(2) Connect the PC and HVS-GPIO128 using LAN.
(3)Launch a terminal software on the PC
(4)Specify 192.168.0.40 (IP address of HVS-GPIO128) to connect to the HVS-GPIO128.
4-2. If Connecting via RS-232C
(1) Use an RS-232C cable to connect the PC to the SERVICE port on the HVS-GPIO128.
(2) RS-232C communication specifications of the HVS-GPIO128 are as shown below.
Set the PC RS-232C communication settings accordingly.
HVS-GPIO128
Serial Communication Specifications
Baud rate
38,400 bps
Data bit
8-bit (fixed)
Parity
None (fixed)
Stop bit
1-bit (fixed)
Flow control
None
(3) Open a terminal software on the PC.
(4) Select RS-232C serial communication to connect to the HVS-GPIO128.
2 -DC12V IN- 1
SERVICE 1 2 3 4
GPI 2GPI 1 GPI 3 GPI 4
RATING LABEL
SERI AL
MFR-LAN
PC
Terminal software

14
4-3. Changing HVS-GPIO128 IP Address
Connect to the switcher and open the Setup menu. The followings are factory default menu settings.
1. Setup Unit IP Address
[ 192.168.0.40 ]
2. Setup Subnet Mask
[ 255.255.255.0 ]
3. Setup Gateway Address
[ 192.168.0.1 ]
4. Setup Target IP Address
[ 192.168.0.80 ]
5. Setup Target TCP Port (1…65535)
[ 52001 ]
6. Save and Reboot
7. Exit without Save
No.
Item
Default
Description
1
Unit IP Address
192.168.0.40
Sets IP address of HVS-GPIO128.
2
Subnet Mask
255.255.255.0
Sets Netmask of HVS-GPIO128.
3
Gateway Address
192.168.0.1
Sets Default gateway of HVS-GPIO128.
4
Target IP Address
192.168.0.80
Specifies IP address of the target HVS
switcher.
5
Target TCP Port
52001
Sets the Send (HVS switcher’s ) TCP port
address.
◆Changing Network Settings
(1) Enter “#“ in the terminal.
(2) Then, enter “setup” (case ignored) and press Enter.
(3) The Setup menu content appears as shown below.
(4) At first, to change the GPI Unit’s IP address, type “1” in the terminal, then press Enter.
>1
(5) Type a new IP address, then press Enter.
IP : 192.168.0.30
(6) The screen returns to the Setup menu top.
Verify that the new IP address is set.
1. Setup Unit IP Address
[ 192.168.0.30 ]
2. Setup Subnet Mask
[ 255.255.255.0 ]
3. Setup Gateway Address
[ 192.168.0.1 ]
4. Setup Target IP Address
[ 192.168.0.80 ]
5. Setup Target TCP Port (1…65535)
[ 52001 ]
6. Save and Reboot
7. Exit without Save
(7) Change other settings, as needed, in the same manner.
(8) After all settings are complete, type “6”, then press Enter.
HVS-GPIO128 will automatically restart and changes are applied.
* To close the Setup menu without changing settings, type “7”, then press Enter.

15
4-4. Resetting the Setup Menu
To reset settings to factory default, use an internal switch on the HVS-GPIO128.
Proceed as follows.
(1)Power off the HVS-GPIO128.
(2) Unsecure two screws on both sides to remove the top plate.
(3) Turn on Dipswitch S4-4. (See Sec. 2-4. “Internal Settings.”)
(4) Power on the HVS-GPIO128.
(5) Check that POWER indicator on the front panel lights green.
(6) Power off the HVS-GPIO128.
(7)Turn off Dipswitch S4-4.
(8) Return the top panel and secure two removed screws.
(9) HVS-GPIO128 will be reset to factory default.

16
5. Specifications and Dimensions
5-1. Unit Specifications
Maximum connection number
1
Interfaces for switcher
Serial
RS-232C or RS-422 9-pin D-sub (male) x 4
GPI
GPI IN, GPI OUT or TALLY OUT
37-pin D-sub (female) x 4
Total 128 GPI connections (Function free assignable)
Other interfaces
LAN
10/100BASE-TX RJ-45 x 1 (for switcher connection)
SERVICE
RS-232C 9-pin D-sub (male) x 1 (for service use)
Temperature
0℃to 40℃
Humidity
30% to 85% (no condensation)
Power
+12V DC, pin connector x 2 (for power redundancy)
Power consumption
100V to 120V AC, 8 VA (4 W)
200V to 240V AC, 13 VA (6 W)
Dimensions
430(W) x 44(H) x 110 (D) mm EIA1RU
480(W) (W/ rack mount brackets)
Weight
1.6 kg
5-2. External Dimensions
(All dimensions in mm)
LA N GPI 1 GPI 2 GPI 3 GPI 4 2 - DC12V IN -1
RATING LABEL
SERIAL
SERVICE 1234
POWER LAN SERIAL
GPI 1 2 3 4 RESET
HVS-GPIO128
GPI UNIT
430
462
480
632 6
44 2.3 110
28 9
12 20 12
42
LAN GPI 1 GPI 2 GPI 3 GPI 4 2- DC12V IN -1
RATING LABEL
SERIAL
SERVICE 1234
POWER LAN SERIAL
GPI 1 2 3 4 RESET
HVS-GPIO128
GPI UNIT
430
462
480
632 6
44 2.3 110
28 9
12 20 12
42

Warning
This equipment has been tested and found to comply with the limits for a
Class A digital device, pursuant to Part 15 of FCC Rules. These limits are
designed to provide reasonable protection against harmful interference
when the equipment is operated in a commercial environment. This
equipment generates, uses, and can radiate radio frequency energy and,
if not installed and used in accordance with the instruction manual, may
cause harmful interference to radio communications. Operation of this
equipment in a residential area is likely to cause harmful interference, in
which case the user will be required to correct the interference at his own
expense.

FOR-A COMPANY LIMITED
Head Office 3-8-1 Ebisu, Shibuya-ku, Tokyo 150-0013, Japan
Overseas Division Tel: +81(0)3-3446-3936 Fax: +81(0)3-3445-5116
Japan Branch Offices Osaka/Okinawa/Fukuoka/Hiroshima/Nagoya/Sendai/Sapporo
R&D/Production Sakura Center/Sapporo Center
FOR-A Corporation of America Corporate Office/Service Center
11155 Knott Ave., Suite G, H & I, Cypress, CA 90630, U.S.A.
Tel: +1 714-894-3311 Fax: +1 714-894-5399
FOR-A Corporation of America Northeast Office
1360 Clifton Ave., Clifton, NJ 07012, U.S.A.
Tel: +1 973-220-8471 Fax: +1 714-894-5399
FOR-A Corporation of America Southeast Office
Tel: +1-305-773-7608
FOR-A Corporation of America Support Center
2400 N.E. Waldo Road, Gainesville, FL 32609, U.S.A.
Tel: +1 352-371-1505 Fax: +1 714-894-5399
FOR-A Latin America and the Caribbean Miami Office
Tel: +1 657-600-5759
FOR-A Latin America and the Caribbean Sao Paulo Office
Tel: +55 (0)11-99913-3751
FOR-A Europe S.r.l.
Via Volturno, 37, 20861 Brugherio MB, Italy
Tel: +39 039-916-4811 Fax: +39 039-878-140
FOR A UK Limited
Trident Court, 1 Oakcroft Road Chessington, KT9 1BD, U.K.
Tel: +44 (0)20-3044-2935 Fax: +44 (0)20-3044-2936
FOR-A Italia S.r.l.
Via Volturno, 37, 20861 Brugherio MB, Italy
Tel: +39 039-881-086/103 Fax: +39 039-878-140
FOR-A Corporation of Korea
1007, 57-5, Yangsan-ro, Yeongdeungpo-gu, Seoul 07271, Korea
Tel: +82 (0)2-2637-0761 Fax: +82 (0)2-2637-0760
FOR-A China Limited
1618 Huateng Building, No. 302, 3 District, Jinsong, Chaoyang, Beijing 100021, China
Tel: +86 (0)10-8721-6023 Fax: +86 (0)10-8721-6033
FOR-A Middle East Africa Office
Aurora Tower, Office 1407, Dubai Media City, P.O. Box 502688, Dubai, UAE
Tel: +971 (0)4 551 5830 Fax: +971 (0)4 551 5832
FOR-A India Private Limited. Mumbai Office
2nd Floor, Valecha Chambers, Link Road, Andheri (W), Mumbai 400053, India
Tel : +91-(0)22-2673-3623 Fax:+91-(0)22-2639-3415
FOR-A India Private Limited. Delhi Office
8th floor, World Trade Tower, Sector-16, Noida, Uttar Pradesh 201301, India
Tel: +91-(0)12-0423-8674
FOR-A South East Asia Office
Studio 09, Rm. A1, 3/F., Phase 1, Hang Fung Ind. Bldg., 2G Hok Yuen St., Hung Hom, Hong Kong
Tel : +852 2110-1352
March 11, 2021 Printed in Japan
http://www.for-a.com/