The terminal block Out - is connected to the negative
terminal (-) of the device.
The Mirco PV inverter is connected to the load outputs
- Output 1 - and/ or - Output 2. The respective terminal
Out + is connected to the connector for the positive
photovoltaic voltage (+). The terminal Out - is
connected to the negative connector (-) of the Micro
PV inverter.
You can use the supplied 6x MC4 contact plugs to
connect the electrical loads. Take the MC4 plugs with
the red cables for the connection of the positive +
photovoltaic voltage and the MC4 plugs with the blue
cables for the negative - photovoltaic voltage.
OPERATION
Operation:
When the device is commissioned, the number of
connected photovoltaic modules is determined after
the 5:00 minute timer has expired. After proper
installation, the switching device automatically
switches the photovoltaic modules to the connected
loads. This is done depending on the incoming
photovoltaic power. No operation by the user is
possible. The display is used to read the current
system status during operation. The display is
structured as follows:
If several outputs are active, they are displayed
sequentially. If only one output is active, the display is
not switched.
If the display - Check Output 1 - is shown on the
display, the switching device waits for the load to
automatically switch to Output 1. If no power is
consumed by the connected load, the switching
device switches the photovoltaic modules to the
second output. Switching is fully automatic and can
take up to 5 minutes per output.
If an output takes up little power, the modules
connected there are switched to another output after
a short time. This ensures that the prioritization (see
section above, Prioritization) of the outputs is
maintained and the best possible use of the
photovoltaic modules is ensured. This scenario is
indicated by the following image about the device,
where an arrow indicates in which direction the
module, or modules, will be transferred after the
output is switched off. In the example shown, the
module connected to output 2 is switched to the left,
i.e. to the first output.
MAINTENANCE AND
REPAIR
To clean the switching device, remove all electrical
connections first. The outer shell and the plastic parts
of the device can only be cleaned with a slightly damp
cotton cloth, without aggressive and/ or abrasive
cleaning agents. The device can only be put back into
operation after complete removal of moisture.
DISTURBANCES
If a fault occurs during use of the system, please
disconnect all live lines from the device and contact
the manufacturer or your dealer.
Display does not light up during the day despite
connected photovoltaic modules: Please contact your
dealer.
Check Output X: The switching device searches for a
suitable load. This can occur especially in very poor
lighting conditions (eg sunrise and sunset). In this
case, less power is available from the photovoltaic
modules than the consumer needs to switch on/
operate.
ENVIRONMENTAL
PROTECTION
This device is marked in accordance with the
Electrical and Electronic Waste Directive (WEEE). By
ensuring that the device is delivered to a suitable
disposal centre at the end of its service life, you
contribute to protecting the environment and
avoiding negative effects on the environment and
human health. The symbol on the hot water tank
indicates that the appliance must not be disposed of