fothermo 1010-SWD-1600 User manual

EN
PHOTOVOLTAIC EXCESS MANAGEMENT SYSTEM -
SWITCHING DEVICE
TECHNICAL DESCRIPTION AND INSTALLATION, OPERATING,
AND MAINTENANCE INSTRUCTIONS,
WARRANTY CONDITIONS

Table of Contents / Inhaltsverzeichnis
EN - Specifications 3
GENERAL WARNINGS...............................................................................................................................................................4
SAFETY INSTRUCTIONS ..........................................................................................................................................................4
TECHNICAL DATA.....................................................................................................................................................................4
APPLICATION ...........................................................................................................................................................................5
INSTALLATION .........................................................................................................................................................................5
OPERATION ..............................................................................................................................................................................6
MAINTENANCE AND REPAIR ...................................................................................................................................................6
DISTURBANCES........................................................................................................................................................................6
ENVIRONMENTAL PROTECTION.............................................................................................................................................6
WARRANTY ...............................................................................................................................................................................7
Contact/ Contact:
fothermo System AG Phone: +49 (0) 7346 9649960
In the strong field 45b Email: contact@fothermo.com
89231 Neu-Ulm Registration court Ulm: HRB 739609Germany
VAT: DE329022123
IMPORTANT!
Please read these operating instructions carefully before installing and commissioning!
IMPORTANT!
Please read this manual before installation and commissioning!

EN - Specifications
Unit
Switching device
IP protection class
-
20
Integrated reverse polarity protection
-
Yes
Digital display
-
Yes
Dimensions (length, width, height)
cm
17.9 x 7.6 x 4.1
Weight
g
400
Photovoltaic connection
Number of connectable photovoltaic modules
-
1-4
Recommended photovoltaic power per photovoltaic module
Wp
300-450
Maximum photovoltaic power per photovoltaic module
Wp
450
Maximum open circuit voltage of a photovoltaic module
VOC
50
Important: The connected photovoltaic modules must match the electrical properties (max. Current, max voltage) of the
connected consumers. The switching device switches individual (entire) photovoltaic modules. There is no regulation of
power or voltage in the changeover device. If the connected load is not compatible with the photovoltaic modules, the
electrical loads can be destroyed.
Connectable electrical loads
Number of outputs for fothermo photovoltaic boiler
-
1
Maximum power - output 1
W
600
Number of outputs for Micro PV inverters
-
2
Maximum power of the connected micro PV inverter
W
800
Maximum performance - Output 2 - and - Output 3 -
W
400
Important: The connected photovoltaic modules must match the electrical properties (max. Current, max voltage) of the connected
consumers. The switching device switches individual (entire) photovoltaic modules. If the connected load is not compatible with the
photovoltaic modules, the electrical loads can be destroyed.

EN
GENERAL WARNINGS
Read the instructions and warnings in this manual
carefully before installing and commissioning the
switching device. The information provided here is
intended to familiarize you with the installation and
operation of the device. Furthermore, you are obliged
to provide this manual to the competent persons who
will install and possibly repair the device. These
instructions should always be kept near the device for
later reference. Compliance with the rules described
here is one of the measures for the safe use of the
product and is considered part of the warranty
conditions.
SAFETY INSTRUCTIONS
WARNING! This device can be used by children from 8
years of age and above as well as by people with
reduced physical, sensory, or mental abilities or lack
of experience and knowledge, if they have been
supervised or instructed in the safe use of the
equipment and understand the resulting hazards.
Children are not allowed to play with the device.
Cleaning and maintenance must not be carried out by
children without supervision.
OTHER IMPORTANT NOTES
•Observe the maximum permissible voltage of
the photovoltaic modules and the electrical
loads to be connected.
•The connected loads must be compatible with
the connected photovoltaic modules.
•The device must be installed in a dry place.
•Only one module per input may be connected to
the limits specified in the specifications.
•Photovoltaic modules in parallel or series
connection must not be connected to the system
inputs.
TECHNICAL DATA
The switching device distributes the power of several
photovoltaic modules to different electrical loads.
The product primarily serves as an energy
management system. The energy generated by the
photovoltaic modules can be distributed efficiently
and with different priorities to the connected loads by
the switching device.
Up to four photovoltaic modules can be connected to
the switching device. For this purpose, the
photovoltaic inputs - PV1 to PV4 - are used. The energy
generated by the photovoltaic modules is distributed
to up to three electrical consumers. These are
connected to the load outputs - Output 1 to Output 3
- (see graphic)
Prioritization:
The switching device prioritizes the connected loads
differently. The output - Output 1 - has first priority.
This is followed by - Output 2 - and then - Output 3 -,
On - Output 1 - connected loads are prioritized and
supplied with energy. If the photovoltaic modules
generate more power than the consumers connected
under - Output 1 - can use, individual/ entire
photovoltaic modules are switched to the second
load output - Output 2 -. If surplus energy is also
available, the - Output 3 - output is also supplied with
energy. If a consumer does not consume power
(anymore) (eg fothermo photovoltaic boiler has
reached the maximum temperature), the existing
power (photovoltaic modules) is switched to the other
connected consumers with a lower priority if possible.
If more power from the photovoltaic modules is
available than the maximum power specified by the
outputs (600W or 400W), individual photovoltaic
modules are temporarily switched off.

EN
APPLICATION
IMPORTANT: Make sure that the connected
consumers are compatible with the permissible
system specifications of the photovoltaic modules.
fothermo Boiler + Micro PV Inverter*
The switching device allows the use of excess energy,
which can no longer be stored in the fothermo
photovoltaic boiler as heat.
* For the connection of an inverter, the use of Mirco PV
inverters" or "balcony power plant inverters" is
provided. these are limited to a power of 400W per
photovoltaic module input. It should be noted that
the inverter has a separate input for each photovoltaic
module. If several photovoltaic modules can be
connected to one input of the inverter, the use in
combination with the switching device is not possible.
INSTALLATION
1. Assembly: Install the switching device in a dry
room. It is mounted on a fixed wall using the four
screws supplied. During installation, sufficient
distance to neighbouring walls and enough distance
under the device for photovoltaic connections must
be provided.
2. Connection of photovoltaic modules:
IMPORTANT! Operation is performed with direct
current.
IMPORTANT! Only photovoltaic modules of the same
type may be individually switched the inputs of the
switching device.
IMPORTANT! A series or parallel connection of the
photovoltaic modules at one input leads to a defect of
the device.
IMPORTANT! The connected photovoltaic modules
must comply with the electrical limitations of the
connected loads.
IMPORTANT! The installation of PV modules may only
be carried out by a competent person and must
exclude any risk to third parties. When installing the
photovoltaic modules, the local rules and laws must
be observed.
IMPORTANT! Only photovoltaic modules with a
maximum open circuit voltage of 50 V specified in the
data sheet may be connected. Up to four photovoltaic
modules with 450Wp each may be connected to the
designated connections of the system.
The photovoltaic modules and the loads are
connected via the screw terminals of the switching
device. The connections for the photovoltaic modules
on the switching device are marked in green. Make
sure that the photovoltaic modules are connected
with the correct polarity.
Start by connecting the photovoltaic modules to the
left of the terminal strip at the first terminal (PV1+) for
the positive (+) and (PV1-) for the negative terminal (-)
of a photovoltaic module. Mount further modules
from left to right in ascending order of numbers
according to the principle described above.
Check that the display of the switching device lights
up after connecting the first photovoltaic module.
After connecting the first photovoltaic module, a
timer of 5:00 minutes begins to count. You should
connect all photovoltaic modules within this given
time. This ensures that the switching device detects
all photovoltaic modules and ensures perfect
operation.
If you could not connect all photovoltaic modules to
the switching device within 5:00 minutes, you should
disconnect all photovoltaic modules from the
switching device and restart the timer.
The device is completely disconnected from the
power supply system when all supply plugs/
photovoltaic modules are disconnected.
3. Connection of electrical consumers: The loads are
mounted on the blue terminals. At the first load
output - output 1 - the fothermo photovoltaic boiler is
connected. For this purpose, the terminal with the
designation Out + is connected to the connector for
the positive photovoltaic module voltage (+).

EN
The terminal block Out - is connected to the negative
terminal (-) of the device.
The Mirco PV inverter is connected to the load outputs
- Output 1 - and/ or - Output 2. The respective terminal
Out + is connected to the connector for the positive
photovoltaic voltage (+). The terminal Out - is
connected to the negative connector (-) of the Micro
PV inverter.
You can use the supplied 6x MC4 contact plugs to
connect the electrical loads. Take the MC4 plugs with
the red cables for the connection of the positive +
photovoltaic voltage and the MC4 plugs with the blue
cables for the negative - photovoltaic voltage.
OPERATION
Operation:
When the device is commissioned, the number of
connected photovoltaic modules is determined after
the 5:00 minute timer has expired. After proper
installation, the switching device automatically
switches the photovoltaic modules to the connected
loads. This is done depending on the incoming
photovoltaic power. No operation by the user is
possible. The display is used to read the current
system status during operation. The display is
structured as follows:
If several outputs are active, they are displayed
sequentially. If only one output is active, the display is
not switched.
If the display - Check Output 1 - is shown on the
display, the switching device waits for the load to
automatically switch to Output 1. If no power is
consumed by the connected load, the switching
device switches the photovoltaic modules to the
second output. Switching is fully automatic and can
take up to 5 minutes per output.
If an output takes up little power, the modules
connected there are switched to another output after
a short time. This ensures that the prioritization (see
section above, Prioritization) of the outputs is
maintained and the best possible use of the
photovoltaic modules is ensured. This scenario is
indicated by the following image about the device,
where an arrow indicates in which direction the
module, or modules, will be transferred after the
output is switched off. In the example shown, the
module connected to output 2 is switched to the left,
i.e. to the first output.
MAINTENANCE AND
REPAIR
To clean the switching device, remove all electrical
connections first. The outer shell and the plastic parts
of the device can only be cleaned with a slightly damp
cotton cloth, without aggressive and/ or abrasive
cleaning agents. The device can only be put back into
operation after complete removal of moisture.
DISTURBANCES
If a fault occurs during use of the system, please
disconnect all live lines from the device and contact
the manufacturer or your dealer.
Display does not light up during the day despite
connected photovoltaic modules: Please contact your
dealer.
Check Output X: The switching device searches for a
suitable load. This can occur especially in very poor
lighting conditions (eg sunrise and sunset). In this
case, less power is available from the photovoltaic
modules than the consumer needs to switch on/
operate.
ENVIRONMENTAL
PROTECTION
This device is marked in accordance with the
Electrical and Electronic Waste Directive (WEEE). By
ensuring that the device is delivered to a suitable
disposal centre at the end of its service life, you
contribute to protecting the environment and
avoiding negative effects on the environment and
human health. The symbol on the hot water tank
indicates that the appliance must not be disposed of

EN
in normal household waste at the end of its service
life. It must be returned to a waste disposal centre
with special facilities for electrical or electronic
equipment. The end user must observe the local
disposal regulations when disposing of the waste. You
can obtain further information about the treatment,
utilization and recycling process from your city
administration, your local waste disposal centre or
the specialist dealer where you purchased the
product.
WARRANTY
The warranty for the appliance shall apply only under
the following conditions:
•The device is installed according to the assembly
and operating instructions.
•The device is only used for its intended purpose
and in accordance with the assembly and
operating instructions.
The warranty covers the rectification of all
manufacturing defects that may occur during the
warranty period. Only the specialists authorized by
the seller may carry out the repairs. The warranty does
not cover damage:
•improper transport,
•improper storage,
•improper use,
•improper electrical voltage deviating from the
rated voltage,
•extraordinary risks, accidents or other force
majeures,
•non-compliance with the assembly and
operating instructions and
•in all cases when an unauthorized person tries to
repair the device.
In the aforementioned cases, the damage will be
remedied against payment. The warranty of the
device does not apply to parts and components of the
device that are worn during its usual use, even parts
that are dismantled during normal use, for lights and
signal lamps, etc., for discoloration of external
surfaces, for changing the shape, dimension and
arrangement of parts and components that have been
exposed to an effect not in accordance with the
normal conditions for use of the device. The warranty
of the device does not cover lost benefits, material
and immaterial damage due to temporary
impossibility to use the device during its repair and
maintenance.
COMPLIANCE WITH THE REQUIREMENTS SPECIFIED
IN THE MANUAL IS A PREREQUISITE FOR THE SAFE
OPERATION OF THE PURCHASED PRODUCT AND IS
PART OF THE WARRANTY CONDITIONS. ANY
MODIFICATION OR MODIFICATION TO THE DESIGN OF
THE PRODUCT BY THE USER OR ANY PERSON
AUTHORIZED BY THE USER IS STRICTLY PROHIBITED.
IF SUCH ACTIONS OR ATTEMPTS ARE DETERMINED,
THEN THE WARRANTY OBLIGATIONS OF THE
MANUFACTURER OR THE DEALER ARE INVALID. THE
MANUFACTURER RESERVES THE RIGHT TO MAKE
STRUCTURAL CHANGES WITHOUT NOTICE PROVIDED
THAT THE SAFETY OF THE PRODUCT IS NOT
AFFECTED. IF NECESSARY OR IF THERE ARE ANY
MISUNDERSTANDINGS IN CONNECTION WITH THE
TRANSLATION AND THE TERMS USED IN THIS
LANGUAGE VERSION OF THE ASSEMBLY AND
INSTRUCTIONS, PLEASE USE THE ENGLISH VERSION
AS THE ORIGINAL AND THE PRIORITY VERSION
Table of contents
Popular Switch manuals by other brands

Altusen
Altusen KH-88 user manual

Cisco
Cisco 2975 - Catalyst LAN Base Switch Hardware installation guide

Siemens
Siemens Sirius 3RT1926-2E Original operating instructions

S&C
S&C Omni-Rupter Installation

Rockwell Automation
Rockwell Automation Allen-Bradley Lifeline 4 Application Technique

Ametek
Ametek SWI F001 Installation and operation manual