Setting to Work
Safe service in use necessitates the strict observance of the following precautions.
Any article fabricated from quartz or glass is inherently fragile and care should
therefore be taken, at all times, when handling lamps;
Eye protection must be worn when handling lamps that have been removed from
their packaging materials. The protective sleeve should not be removed from the
lamp for safety reasons, as there is a remote possibility of the lamp shattering
violently, especially if it is subjected to mechanical shock or vibration;
Ensure that the power rating of the lamp to be fitted is suitable for the lamphouse
and power supply equipment;
Always isolate the equipment from the supply before inserting a lamp;
Before inserting the lamp ensure that all contacts are clean. Contacts must be
renewed at the slightest sign of corrosion. Sanding or filing down corroded areas is
not recommended as this will only make the conducting surface between the pin
and lampholder smaller, thus causing the lamp to overheat;
Do not twist or bend the fused quartz bulb when fitting the lamp as mechanical
stresses MUST be avoided;
When inserting or removing a lamp, always hold it securely by its’ base in order to
prevent breakage between base and bulb;
The lampholder must not exercise mechanical tensions on the lamp, neither during
insertion or operation. Contacts must not discolour during use;
For safety reasons, the lamp should be replaced once it has reached its’ average
life, and not later than 1.25 times the stated life. With continuing use the risk of the
lamp exploding increases due to alterations within the quartz;
Before the protective sleeve is removed, suitable protection must be worn i.e face
mask and gloves with wrist protection;
Never touch the quartz bulb with bare hands, as fingerprints will make the glass
cloudy and cause a severe loss of light. This may also cause recrystallisation and
thus weaken the bulb material. Should the bulb be inadvertently touched, remove
fingerprints with methylated spirit and a clean, soft paper towel. The bulb should
then be wiped with distilled water. NOTE: ALWAYS WEAR MASK AND GLOVES
DURING CLEANING);
All packaging and the protective sleeve must be retained for re-use. Whenever
removing a lamp, the protective sleeve must always be used for safety reasons;
In all circumstances the lamp manufacturer’s data should be referred to when dealing
with lamps.