FRC ICA100 Series User manual

ICA100 Rev171109
1
INTERCOM
AMBULANCE/RESCUE VEHICLE
MODEL ICA100
SURFACE MOUNT SERIES
MODELS ICA200, ICA300
FLUSH MOUNT SERIES
MODELS ICA400, ICA500
Document Number:
XE-ICA1PM-R0A
FIRE RESEARCH CORPORATION
www.reresearch.com
26 Southern Blvd., Nesconset, NY 11767
TEL 631.724.8888 FAX 631.360.9727 TOLL FREE 1.800.645.0074
ICA200/300
ICA400/500
ICA100

ICA100 Rev171109
2
CONTENTS Table of Contents
CONTENTS................................................................................................................ 2
INTRODUCTION ...................................................................................................... 3
Overview................................................................................................................ 3
Features.................................................................................................................. 3
Specications......................................................................................................... 3
GENERAL INSTALLATION NOTES....................................................................... 4
ICA100 SERIES INSTALLATION............................................................................ 5
Pre-Installation....................................................................................................... 5
Install Remote Station............................................................................................ 5
Install Master Station ............................................................................................ 5
ICA200/300 SERIES INSTALLATION..................................................................... 8
Pre-Installation....................................................................................................... 8
Install Remote Station............................................................................................ 8
Install Master Station(s)......................................................................................... 8
ICA400/500 SERIES INSTALLATION................................................................... 12
Pre-Installation..................................................................................................... 12
Install Remote Station.......................................................................................... 12
Install Master Station(s) ...................................................................................... 12
OPERATION ............................................................................................................ 16
Basic Two-Way System ....................................................................................... 16
Basic Three-Way System..................................................................................... 16
System Options.................................................................................................... 16
Operational Check ............................................................................................... 17
List of Tables
Table 1. Intercom Specications................................................................................ 3
List of Figures
Figure 1. ICA100 Mounting Dimensions .................................................................. 6
Figure 2. ICA100 Wiring ........................................................................................... 7
Figure 3. ICA200/300 Adjustable Mount .................................................................. 9
Figure 4. ICA200/300 Mounting Dimensions ........................................................... 9
Figure 5. ICA200 Wiring ......................................................................................... 10
Figure 6. ICA300 Wiring ......................................................................................... 11
Figure 7. ICA400/500 Mounting Dimensions ......................................................... 13
Figure 8. ICA400 Wiring ......................................................................................... 14
Figure 9. ICA500 Wiring ......................................................................................... 15

ICA100 Rev171109
3
INTRODUCTION
Overview
Fire Research intercoms are designed to meet rescue and re service requirements
for two or three-way voice communications system. The ICA100 series intercom
systems are designed for use inside ambulances and rescue vehicles. The ICA200/300
surface mount and ICA400/500 ush mount series intercom systems are weather-
resistant and specically designed for outside use on re service apparatus.
Features
Master station with volume and push-to-talk controls
Remote station is operated hands free
Dual master stations for three-way systems
Adjustable mount (ICA200/300 Series)
Hand-held microphone option for master stations
Foot switch option for master stations
Specications
SERIES ICA100 ICA200/300 ICA400/500
SUPPLY
VOLTAGE 12 VDC 12 VDC 12 VDC
OUTPUT
POWER 8 WATTS 16 WATTS 16 WATTS
FUSE 3 AMP
RECOMMENDED
3 AMP
SLOW BLOW
.25" X 1.25" MDL
3 AMP
SLOW BLOW
.25" X 1.25" MDL
DIMENSIONS
MASTER
(IN INCHES)
5.25 x 4 x 1.5 8.25 x 5.625 x 3
(Without Bracket)
6.25 x 7.25
(Panel Dimensions)
3" Clearance Required
Behind Panel
DIMENSIONS
REMOTE
(IN INCHES)
4.375 x 3.25 x 1.5 5.25 x 5.25 x 2.25
(Without Bracket)
5.625 x 6
(Panel Dimension)
2.5" Clearance Required
Behind Panel
Handheld
Microphone N/A Optional Optional
PTT Button for
Remote Station Optional Optional Optional
Table 1. Intercom Specications

ICA100 Rev171109
4
GENERAL INSTALLATION NOTES
Mount the intercom stations in locations that are safe and convenient for use.
It is recommended that the master station be mounted inside the cab.
Consider potential background noise that the hands free remote station might
pick up.
If excess background noise is picked up by the hands free remote station due to
vibration, mounting it on a rubber pad can help reduce noise.
Ensure a good ground connection. Isolate the intercom ground wire from other
grounds that can be noisy (strobes, radios, priming motors, etc.).
Make interconnecting cable runs as short as possible.
Secure excess intercom cable in a gure 8 pattern.
The foot switch option requires the installation of a single-pole single-throw
switch (not supplied with intercom).

ICA100 Rev171109
5
ICA100 SERIES INSTALLATION
Pre-Installation
1. Measure and mark station locations for two mounting holes. Refer to Figure
1 for layout and dimensions.
2. Drill two 3/4-inch mounting holes at each station location.
3. Install the four conductor cable between station locations.
4. Remove nuts from mounting post on intercom boxes.
Install Remote Station
1. Place station box in position with mounting post through the holes and secure
with two nuts. (The nuts should be hand tight plus 1/4 turn.)
2. Connect station box four wires to cable. Refer to Figure 2 for wiring details.
Install Master Station
1. Place station box in position with mounting post through the holes and secure
with two nuts. (The nuts should be hand tight plus 1/4 turn.)
2. Connect station box four wires to cable. Refer to Figure 2 for wiring details.
3. Connect black wire to ground.
4. Connect red wire to +12 VDC.

ICA100 Rev171109
6
Figure 1. ICA100 Mounting Dimensions
Two 3/4” holes are
needed.
Remote Station
Master Station
Two 3/4" holes are
needed.
4"
2 5/8"
3/4"
3/4"
2 1/2"
5 1/4"
4 3/8"
2 1/4"
1 5/8"
3 1/4"
1 1/16"
1 1/16"

ICA100 Rev171109
7
Figure 2. ICA100 Wiring
Note: It is recommended that a 3 AMP fuse
be installed between the master station box
and the 12 VDC power source.
Master Station
+12 VDC
GND
Red
Black Yellow
White
Red
Black
Remote Station
Black
White
Yellow
Red
A one-to-one cable
connects the two stations.
Black-to-Black
White-to-White
Red-to-Red
Yellow-to-Yellow
Master station
may have
a power on
LED.

ICA100 Rev171109
8
ICA200/300 SERIES INSTALLATION
Note: In a three-way system (ICA300) master station A has transmit priority
over master station B and the remote station.
Note: Mounting hardware is not included, 1/4-inch hardware is recommended.
Pre-Installation
Note: The mounting bracket can be removed by unscrewing the adjustment
knobs at the side of the station box (Refer to Figure 3).
1. Measure and mark station box locations for mounting bracket installation.
Refer to Figure 4 for layout and dimensions.
2. Drill four mounting holes at each station box location for mounting hardware.
Note: Pre-installed apparatus wiring can be used. The intercom connections
are one-to-one. The yellow wire is shield.
3. Install the cable (with 3-pin connector) between remote and master station box
locations. Refer to Figure 5 or 6 for wiring details.
4. For three-way system (ICA300) install the cable (with 5-pin connector) between
master stations A and B box locations. Refer to Figure 6 for wiring details.
Install Remote Station
1. Place mounting bracket in position and secure with four screws.
2. If bracket was removed from box, place remote station box in position and
install rubber bushings and mounting knobs.
3. Connect station box 3-pin Molex connector to cable connector.
Install Master Station(s)
1. Place mounting bracket(s) in position and secure with four screws.
2. If bracket was removed from box, place master station(s) in position and install
rubber bushings and mounting knobs.
3. Connect station box 3-pin Molex connector to cable connector.
4. For three-way system (ICA300) connect station box 5-pin Molex connector to
cable connector.
5. Connect black wire to ground.
6. Connect red fused wire to +12 VDC.
7. For three-way system repeat steps 4 through 6 at master station B.

ICA100 Rev171109
9
Remote Station Bracket
Mounting Holes
Master Station Bracket
Mounting Holes
Figure 4. ICA200/300 Mounting Dimensions
Drill the holes for 1/4-inch
mounting hardware.
4 1/4"
3/4"
3/4"
3"
Figure 3. ICA200/300 Adjustable Mount
Adjustable
Provide enough slack
in the cable(s) for
the station box to be
adjusted as needed.
Station
Box
Adjustment
Knob
Mounting
Bracket
Rubber
Bushing

ICA100 Rev171109
10
To Remote
Station
Figure 5. ICA200 Wiring
Remote Station Master Station
GND
+12 VDC
Fuse
3 AMP
3 Pin
Molex Connector
Wiring
White
Yellow
Black
If the PTT option is installed
on the remote station a 5-pin
Molex will be used.

ICA100 Rev171109
11
To Remote
Station
To Master
Station B
Figure 6. ICA300 Wiring
Remote Station
Fuse
3 AMP
Master Station B
GND
+12 VDC
Master Station A
GND
+12 VDC
Fuse
3 AMP
3 Pin
Molex Connector
Wiring
White
Yellow
Black
5 Pin
Molex Connector
Wiring
Red
-
Yellow
White
Black

ICA100 Rev171109
12
ICA400/500 SERIES INSTALLATION
Note: In a three-way system (ICA500) master station A has transmit priority
over master station B and the remote station.
Note: Mounting hardware is not included, number 10 hardware is recommended.
Pre-Installation
1. Measure and mark station box locations for panel opening and four screw
holes. Refer to Figure 7 for layout and dimensions.
2. Drill four mounting holes at each station box location for mounting hardware.
3. Cut out panel opening at each station location.
Note: Pre-installed apparatus wiring can be used. The intercom connections
are one-to-one. The yellow wire is shield.
4. Install the cable (with 3-pin connector) between remote and master station box
locations. Refer to Figure 8 or 9 for wiring details.
5. For three-way system (ICA500) install the cable (with 5-pin connector) between
master stations A and B box locations. Refer to Figure 9 for wiring details.
Install Remote Station
1. Place station box in position and secure with four screws.
2. Connect station box 3-pin Molex connector to cable connector.
Install Master Station(s)
1. Place station box(es) in position and secure with four screws.
2. Connect station box 3-pin Molex connector to cable connector.
3. For three-way system (ICA500) connect station box 5-pin Molex connector
to cable connector.
4. Connect black wire to ground.
5. Connect red fused wire to +12 VDC.
6. For three-way system repeat steps 3 through 5 at master station B.

ICA100 Rev171109
13
Figure 7. ICA400/500 Mounting Dimensions
Master Station
Cutout and
Mounting Holes
Remote Station
Cutout and
Mounting Holes
Suggested Panel Opening
5 1/8" H x 5 1/8" W
Suggested Panel Opening
6 3/8" H x 5 1/8" W
Drill the holes for number 10
mounting hardware.
6 3/4"
5 1/2"
5 1/2"
5"

ICA100 Rev171109
14
Figure 8. ICA400 Wiring
To Remote
Station
Master Station
GND
+12 VDC
Fuse
3 AMP
Remote Station
3 Pin
Molex Connector
Wiring
White
Yellow
Black
If the PTT option is installed
on the remote station a 5-pin
Molex will be used.

ICA100 Rev171109
15
Figure 9. ICA500 Wiring
To Master
Station B
To Remote
Station
Master Station B
GND
+12 VDC
Fuse
3 AMP
Remote Station
GND
+12 VDC
Fuse
3 AMP
5 Pin
Molex Connector
Wiring
3 Pin
Molex Connector
Wiring
White
Yellow
Black
Red
-
Yellow
White
Black
Master Station A

ICA100 Rev171109
16
OPERATION
Basic Two-Way System
The basic two-way intercom system includes a master station with volume and
Push-To-Talk (PTT) controls and a remote station that is operated hands free. The
remote station is always transmitting unless interrupted by a transmission from the
master station.
Basic Three-Way System
The basic three-way system includes two master stations (A and B) with volume
and PTT controls and a remote station that is operated hands free. The remote station is
always transmitting unless interrupted by a transmission from a master station. Master
station A has transmit priority over master station B and the remote station.
System Options
Handheld Microphone Option
This option is for installations in high noise areas. The microphone plugs into a
receptacle on the station box. The system can be keyed to transmit with the microphone
switch or the PTT button on the station box.
Remote Station with PTT Button Option
This option is for installations where a remote station with hands free operation is
not required. The PTT button will have to be pressed for the remote to transmit.
Foot Switch Option
This option requires the installation of a single-pole single-throw foot switch
(not supplied with intercom). A two conductor cable is wired at the foot switch and
connected at the station box with a 2-pin Molex connector. The system can be keyed
to transmit with the foot switch or the PTT button on the station box.

ICA100 Rev171109
17
Operational Check
Basic Two-Way System
1. Turn on 12 VDC power.
2. Press and hold PTT button on master station box.
3. Speak into the box and adjust volume knob for transmit and receive level.
Result: Voice is heard at remote station.
4. Release PTT button.
5. Speak into remote station box.
Result: Voice is heard at master station.
Basic Three-Way System
1. Turn on 12 VDC power.
2. Press and hold PTT button on master station A box.
3. Speak into the box and adjust volume knob for transmit and receive level.
Result: Voice is heard at remote station and master station B.
4. Release PTT button.
5. Press and hold PTT button on master station B box.
6. Speak into the box and adjust volume knob for transmit and receive level.
Result: Voice is heard at remote station and master station A.
7. Release PTT button.
8. Speak into remote station box.
Result: Voice is heard at master station A and master station B.
Handheld Microphone and Foot Switch Option
Perform basic system test. For a station with either option, repeat the steps that key
the system with the PTT button using the microphone switch or foot switch.
Remote Station with PTT Button Option
Preform basic system test. For a station with the option press and hold the PTT
button to speak into the box.

ICA100 Rev171109
18
NOTES

ICA100 Rev171109
19
NOTES

ICA100 Rev171109
20
This manual suits for next models
4