ICE MAKER INFORMATION
Test Cycling
Remove cover by inserting screwdriver in notch at
bottom and prying cover from housing. Use
screwdriver to rotate motor gear counterclockwise
until holding switch circuit is completed. All
components of ice maker should function to
complete the cycle.
IMPORTANT SAFETY NOTICE
The information provided herein is designed to assist qualified repair
personnel only. Untrained persons should not attempt to make repairs due to
the possibility of electrical shock. Disconnect power cord before servicing.
IMPORTANT
If any green grounding wires are moved during servicing, they must be returned to their original position and properly secured.
CAUTION
System parts must be removed from cabinet before brazing. All electrical parts and wiring must be shielded from torch flame. Do not
allow torch to contact insulation; it will char at 200°F and flash ignite (burn) at 500°F. Excessive heat will distort the plastic liner.
ATADECNAMROFREP GNITTESLORTNOCTNIOP-DIMTASGNINEPOROODONDNADAOLON
roticapaCtratS/nuRhtiWAepyTtneibmAF°56tneibmAF°09
emiTgnitarepO%54ot73%86ot06
erutarepmeTrezeerFF°4ot°0F°3ot°2-
erutarepmeTerutaregirfeRF°93ot°43F°93ot°43
)ni-tuc(erusserPediSwoLgisp21ot5gisp21ot5
))tuo-tuc(erusserPediSwoLgisp2ot2-gisp2ot2-
)elcycfo3/1tsaL(erusserPediShgiHgisp031ot011gisp081ot051
)elcycfo3/1tsaL(egattaW002ot071012ot081
)gninnuR(spmA8.1ot5.18.1ot5.1
egatloVesaBCAV511CAV511
SNOITACIFICEPSTSORFED
eziStenibaC tatsomrehTretaeH
ni-tuCtuo-tuCsttaWsmhO
'82ot'22F°52+F°74+00622
emiTnuRrosserpmoCfosruoH8yrevEsetuniM03tsorfeD
ROTOMNAFRESNEDNOC
sttaWMPRspmA
3.2tfahSetisoppOWC0031gninnuR51.
REPMADCITATSOMREHT
nepOlluFdesolC
F°2-/+F°33F°2-/+F°22
SNOITACIFICEPSREKAMECI
lacirtcelEstloV511ztreH06
tatsomrehTF°84tasnepOF°51tasesolC
egattaWretaeH561
SERVICE DATA SHEET - 218877000
R134a
ICE & WATER - AUTOMATIC DEFROST
SIDE BY SIDE MODELS
Water Fill Volume
The water fill adjustment screw will change the fill
time. One full turn is equal to 20cc (.68 oz.). The
correct fill is 90 to 120cc (3.0 to 4.0 oz.). When a
water valve is replaced, the fill volume must be
checked.