manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. FrSky
  6. •
  7. Control System
  8. •
  9. FrSky Power Switch User manual

FrSky Power Switch User manual

Version
1.0
Instruction Manual for
FrSky Power Switch
FrSky Electronic Co., Ltd. www.frsky-rc.com Contact us : [email protected]
Add: F-4,Building C, Zhongxiu Technology Park, No.3 Yuanxi Road, Wuxi, 214125, Jiangsu, China Technical Support: [email protected]
The Power Switch is a power control system that offers a safe and flexible powering solution for controlling power
in your RC model builds.
The Power Switch provides the user with a safe and efficient way to power the system with your power sources
connected via a pair of standard XT30 connections. Its dual-power consumption system is designed to operate
either in Balance or Backup mode. In Balance Mode (default), it consumes the power line from either power
source depending on which has the higher voltage. When switching to the Backup Mode, the system consumes
the power line with the priority that the user selected under the set voltage range.
A built-in high-quality BEC unit provides the powering solution, supporting dual input and dual output ports with
XT30 connections. The BEC’s design allows the XT30 output ports to be configured to supply 5V to 8.4V either
by Lua script (on ETHOS), or alternatively by using the Press button on the CNC aluminum case to quickly switch
between the different preset voltages. The power switch is capable of working continuously under high current
loads, and benefits from the high-quality machined heat-sink dissipation design.
The power switch function supports multiple types of external switches (e.g. NFC switch, etc.) that enable flexible
options on how the power can be switched on/off without the need to plug/unplug the battery connections.
Introduction
Overview
70mm18.5mm
34mm
Specifications
● Dimension: 70*34*18.5mm (L*W*H)
● Weight: 63.4g
● Battery Input Voltage Range: DC7.4-26V (It is recommended to use 3S-6S Li batteries)
(Note: 2S Li Batteries will not have sufficient input supply voltage to reach the 8.4V BEC output configuration.)
● Continuous Current: up to 25A@5~8.4V
● Operating Temperature: -20℃~75℃
● Battery Input & BEC Output Connector: XT30
Features
● Dual Battery Inputs (Balance / Backup mode)
● Configurable BEC Dual Outputs (by Lua Script)
● Multiple Voltage Modes Fast Switching (by Button - 4 Modes: 5.0V / 6.0V / 7.4V / 8.4V )
● CNC Aluminum Metal Shell with Fin Heat Dissipation Design
● Capable of Working Continuously under High Current Loads
● Working Status LED Indicator
● Compatible with FBUS/S.Port protocol
● Supports Multiple Types of External Switches (Optional, e.g. NFC Switch)
Press Button
Version
1.0
Instruction Manual for
FrSky Power Switch
FrSky Electronic Co., Ltd. www.frsky-rc.com Contact us : [email protected]
Add: F-4,Building C, Zhongxiu Technology Park, No.3 Yuanxi Road, Wuxi, 214125, Jiangsu, China Technical Support: [email protected]
Setup Guide - Dual Power Redundancy
[Power Switch] → [Battery Mode] Select the battery consumption mode.
Note: 1. Please ensure the battery is plugged into BAT1 while using the single battery.
2. Please ensure that both battery’s output power is not lower than the power needed for the
connected devices, otherwise there will be insufficient power supply for the devices.
[Power Switch] → [Switch Thro]
Balance Mode
When the dual batteries are plugged into the device the
Power Redundancy function is automatically activated. The
system is designed to use the battery line from the higher
voltage allowing the balancing of power consumption across
both batteries,When the voltage of the two batteries is the
same, both batteries supply power simultaneously.
Backup Mode
When the primary battery is consumed to the limitation of the
preset voltage, the system will allow the backup battery to
join and enter into the balancing of power consumption
across both batteries. In this mode, the consumption limit of
voltage can be set for the primary battery.
Note: 1. Please move to the [DOWNLOAD] section from the product page to download the functional
Lua scripts (Place the decompressed folder in the root directory of the [Script] folder on the
memory card to use.)
2. Connect the S.Port/FBUS capable receiver by the S.Port port of Power Switch, and run the
[Power Switch] Lua script (in System menu page) after binding the receiver (in FBUS mode)
to the radio system.
ID Set Up
Each type of FrSky device has its unique Physical ID
(Phy ID). When the same type of telemetry comes from a
different device, the Application ID (App ID) should be set
to different.
Note: All S.Port/FBUS capable device can daisy
chain with each other through via S.Port/FBUS.
FrSky Electronic Co., Ltd. www.frsky-rc.com Contact us: [email protected]
Add: F-4,Building C, Zhongxiu Technology Park, No.3 Yuanxi Road, Wuxi, 214125, Jiangsu, China Technical Support: [email protected]
Version
1.0
Instruction Manual for
FrSky Power Switch
Setup Guide - BEC Voltage Outputs
LED Status Indicator
BEC voltage output can be configured from 5-8.4V and
supports devices working with up to 25A current in this
range.
BEC Voltage Setting via Lua Script.
Press Button
LED Status
Lit
Flash
Lit
Slow Flash
Fast Flash
LED
Green LED
(Set)
Red LED
(Voltage Mode)
Blus LED
(S.Port/FBUS)
Operation
Using preset voltage
BEC Voltage in switching by short press button
BEC Voltage saving setted by long press button
Telemetry is working in
S.Port mode
Telemetry is working in
FBUS mode / no receiver signal
Adjusting voltage with buttons.
LED Status
Lit
Flash
Lit
Slow Flash
Fast Flash
LED
Green LED
(Set)
Red LED
(Voltage Mode)
Blus LED
(S.Port/FBUS)
Operation
Using preset voltage
LUA set value is lower than the flicker value
LUA set value is higher than or equal to the constant light value
Telemetry is working in
S.Port mode
Telemetry is working in
FBUS mode / no receiver signal
Adjusting voltage with LUA scripts.

Popular Control System manuals by other brands

Syncronorm VNANO 512 operating instructions

Syncronorm

Syncronorm VNANO 512 operating instructions

OSF Pool control PC-400-ES Installation and operating instructions

OSF

OSF Pool control PC-400-ES Installation and operating instructions

OSF Alarm-control.plus Installation and operation manual

OSF

OSF Alarm-control.plus Installation and operation manual

DAVIS TECHNOLOGIES TMS-9500-SL Short manual

DAVIS TECHNOLOGIES

DAVIS TECHNOLOGIES TMS-9500-SL Short manual

Frico SIReB1X manual

Frico

Frico SIReB1X manual

Meridian Archer-Guard Assembly instructions

Meridian

Meridian Archer-Guard Assembly instructions

HBX CPU-0500 Quick & easy set-up guide

HBX

HBX CPU-0500 Quick & easy set-up guide

Coelbo ONEMATIC easy operating instructions

Coelbo

Coelbo ONEMATIC easy operating instructions

ABB Relion 615 series manual

ABB

ABB Relion 615 series manual

ROTOTILT ICS manual

ROTOTILT

ROTOTILT ICS manual

Pilz PSSuniversal installation manual

Pilz

Pilz PSSuniversal installation manual

Burkert 3232 operating instructions

Burkert

Burkert 3232 operating instructions

RTS DSPK4 Technical manual

RTS

RTS DSPK4 Technical manual

heat-timer Mini-MOD manual

heat-timer

heat-timer Mini-MOD manual

Lennox Harmony III installation instructions

Lennox

Lennox Harmony III installation instructions

Siemens QAX850 operating instructions

Siemens

Siemens QAX850 operating instructions

CENTURION SYSTEMS SupaHelix installation manual

CENTURION SYSTEMS

CENTURION SYSTEMS SupaHelix installation manual

Siemens PCS 7 installation manual

Siemens

Siemens PCS 7 installation manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.