2. Technical pecificationss
3. Start-up and use
-
-
-
-
-
-
-
-
-
Fit the wheels and foot (or the caster wheel for models that are fitted with this) according to the
instructions provided in the packaging. For versions with fixed feet, assemble the front bracket kit or
the vibration-dampers if furnished. Check that the rating data match the effective characteristics of
the system (voltage and power).
Check for correspondence between the compressor plate data with the actual specifications of the
electrical system.Avariation of ± 10% with respect of the rated value is allowed.
Check the oil level using the sight glass and if necessary unscrew the vent plug and top up. (figures
6a-6b).
Insert the power plug in a suitable socket checking that the button of the pressure switch located on
the compressor is in the “O” (OFF) position (figures 5a-5b-5c-5d).
At this point, the compressor is ready for use.
Operating on the switch of the pressure switch (or the selector for versions with electric panel,
(figures 5a-5b-5c-5d), the compressor starts, pumping air in the reservoir through the delivery hose.
The absence of pressure in the head facilitates subsequent restart. When air is used, the compressor
restarts automatically when the lower calibration value is reached (approx. 2 bar between upper and
lower). The pressure inside the reservoir can be checked on the gauge provided (fig. 4).
The compressor continues to operate automatically with this work cycle until the position of the switch
of the pressure switch (figures 5a-5b-5c-5d) is modified. To use the compressor again, wait at least
10 seconds after this has been switched off before restarting.
Only the wheel-mounted compressors are fitted with a pressure reducer (in the versions with fixed
feet, it is usually installed on the use line). Air pressure can be regulated in order to optimize use of
air-powered tools operating on the knob with the valve open (pulling it up and turning it in a clockwise
direction to increase pressure and counterclockwise to reduce this) (fig. 7). Once you have set the
value required, push the knob down to lock it.
- tab.1)
- belt deflection tab.3)
Check that all screws ( .
Check that ( .
The manufacturer reserves himself the right to make the manual's content or function change without any
preliminary notification of the users.
VCF/50 CM3 VCF/100 CM3 B4000B/50 CM3 B4000B/100 CM3
Power, kW
2,2 2,2 2,2 2,2
Tank, l
50 100 50 100
Pressure, bar
10 10 10 10
Air displacement, l/min 440 440 400 400
RPM 1100 1100 1100 1100
Volt/Hz 220/50 220/50 220/50 220/50
Size, mm 830х360х740 1050х420х850 830х360х720 1050х420х850
Weight, kg 50 71 46 66
MODEL
B5200B/100 CT4 B5200B/200 CT4 B6800B/100 CT5 B6800B/200 CT5 B8800/270 CT7,5
Power, kW 3 3 4 4 5,5
Tank, l 100 200 100 200 270
Pressure, bar 10 10 10 10 12
Air displacement, l/min 530 530 690 690 890
RPM 1300 1300 1150 1150 900
Volt/Hz 380/50 380/50 380/50 380/50 380/50
Size, mm 1050х420х850 1500х520х950 1050х450х950 1500х520х990 1430х580х1100
Weight, kg 68 115 75 126 275