FUJIDENZO FIC180G IN User manual

Indoor Unit
Outdoor Unit
FIC360G IN FIO360G OD
Premium DC Inverter Series
Cassette Type Unit
Thank you for choosing these Air Conditioners, please read this owner’s manual carefully
before operation and retain it for future reference.
Fujidenzo reserves the right to interpret this manual which will be subject to any change due to
product improvement without further notice.
FIC180G IN FIO180G OD
FIC240G IN FIO240G OD
FIC480G IN FIO480G OD
FIC600G IN FIO600G OD

Contents
1 Safety Precautions ....................................................................... 1
3 Preparative for Installation............................................................ 4
3.1 Standard Accessory Parts...................................................................4
3.2 Selection of the Installation Location ..................................................5
3.3 Connection Pipe Requirement............................................................7
3.4 Electrical Requirement........................................................................8
4 Installation of the Unit................................................................... 9
4.1 Installation of the Indoor Unit ..............................................................9
4.2 Installation of the Outdoor Unit .........................................................12
4.3 Installation of the Connection Pipe ...................................................13
4.4 Vacuum and Gas Leakage Inspection ..............................................17
4.5 Installation of the Drain Hose............................................................19
4.6 The Panel Installation .......................................................................23
4.7 Electrical Wiring ................................................................................25
5 Installation of Controllers ............................................................ 30
6 Test Running .............................................................................. 31
6.1 Trial Operation and Testing...............................................................31
6.2 Working Temperature Range............................................................33
7 Troubleshooting and Maintenance.............................................. 33
7.1 Troubleshooting ................................................................................33
7.2 Routine Maintenance........................................................................34

Premium DC Inverter Series Cassette Type Unit
1
1 Safety Precautions
WARNING!
This mark indicates procedures which, if improperly performed, might lead to the
death or serious injury of the user.
CAUTION!
This mark indicates procedures which, if improperly performed, might possibly
result in personal harm to the user, or damage to property.
WARNING!
(1). Installation should be left to the dealer or another professional. Improper installation may cause
water leakage, electrical shock, or fire.
(2). Install the air conditioner according to the instructions given in this manual. Incomplete installation
may cause water leakage, electrical shock, or fire.
(3). Be sure to use the supplied or specified installation parts. Use of other parts may cause the unit to
come to lose, water leakage, electrical shock, or fire.
(4). Install the air conditioner on a solid base that can support the weight of the unit. An inadequate
base or incomplete installation may cause injury in the event the unit falls off the base.
(5). Electrical work should be carried out in accordance with the installation manual and the national
electrical wiring rules or code of practice. Insufficient capacity or incomplete electrical work may
cause electrical shock or fire.
(6). Be sure to use a dedicated power circuit. Never use a power supply shared by another appliance.
(7). For wiring, use a cable length enough to cover the entire distance with no connection. Do not use
an extension cord. Do not put other loads on the power supply, use a dedicated power circuit.
(Failure to do so may cause abnormal heat, electric shock or fire.)
(8). Use the specified types of wires for electrical connections between the indoor and outdoor units.
Firmly clamp the interconnecting wires so their terminals receive no external stresses.
Incomplete connections or clamping may cause terminal overheating or fire.
(9). After connecting interconnecting and supply wiring be sure to shape the cables so that they do not
put undue force on the electrical covers or panels. Install covers over the wires. Incomplete cover
installation may cause terminal overheating, electrical shock, or fire.
(10). If any refrigerant has leaked out during the installation work, ventilate the room. (The refrigerant
produces a toxic gas if exposed to flames.)
(11). After all installation is complete, check to make sure that no refrigerant is leaking out. (The
refrigerant produces a toxic gas if exposed to flames.)
(12). When installing or relocating the system, be sure to keep the refrigerant circuit free from
substances other than the specified refrigerant (R410A), such as air. (Any presence of air or other
foreign substance in the refrigerant circuit causes an abnormal pressure rise or rupture, resulting in
injury.)
(13). During pump-down, stop the compressor before removing the refrigerant piping. If the compressor
is still running and the stop valve is open during pump-down, air will be sucked in when the
refrigerant piping is removed, causing abnormal pressure in the freezer cycle which will lead to
breakage and even injury.
(14). During installation, attach the refrigerant piping securely before running the compressor. If the
compressor is not attached and the stop valve is open during pump-down, air will be sucked in
when the compressor is run, causing abnormal pressure in the freezer cycle which will lead to
breakage and even injury.

Premium DC Inverter Series Cassette Type Unit
2
(15). Be sure to establish an earth. Do not earth the unit to a utility pipe, arrester, or telephone earth.
Incomplete earth may cause electrical shock, or fire. A high surge current from lightning or other
sources may cause damage to the air conditioner.
(16). Be sure to install an earth leakage breaker. Failure to install an earth leakage breaker may result in
electric shocks, or fire.
(17). This appliance is not intended for use by persons (including children) with reduced physical,
sensory or mental capabilities, or lack of experience and knowledge, unless they have been given
supervision or instruction concerning use of the appliance by a person responsible for their safety.
(18). Children should be supervised to ensure that they do not play with the appliance.
(19). If the supply cord is damaged, it must be replaced by the manufacturer, its service agent or
similarly qualified persons in order to avoid a hazard.
CAUTION!
(1). Do not install the air conditioner in a place where there is danger of exposure to inflammable gas
leakage. If the gas leaks and builds up around the unit, it may catch fire.
(2). Establish drain piping according to the instructions of this manual. Inadequate piping may cause
flooding.
(3). Tighten the flare nut according to the specified method such as with a torque wrench. If the flare
nut is tightened too hard, the flare nut may crack after a long time and cause refrigerant leakage.

Premium DC Inverter Series Cassette Type Unit
3
2 Outline of the Unit and Main Parts
Fig. 2.1
This manual suits for next models
9
Table of contents
Other FUJIDENZO Air Conditioner manuals
Popular Air Conditioner manuals by other brands

Fujitsu
Fujitsu ASYG 09 LLCA installation manual

York
York HVHC 07-12DS Installation & owner's manual

Carrier
Carrier Fan Coil 42B Installation, operation and maintenance manual

intensity
intensity IDUFCI60KC-3 installation manual

Frigidaire
Frigidaire FAC064K7A2 Factory parts catalog

Sanyo
Sanyo KS2432 instruction manual

Mitsubishi Electric
Mitsubishi Electric PUHZ-RP50VHA4 Service manual

Panasonic
Panasonic CS-S18HKQ Service manual

Panasonic
Panasonic CS-E15NKE3 operating instructions

Gree
Gree GWH18TC-K3DNA1B/I Service manual

Friedrich
Friedrich ZoneAire Compact P08SA owner's manual

Daikin
Daikin R32 Split Series installation manual