FUJIDENZO IWAR90G User manual

Inverter Window Type Air Conditioner
Thank you for choosing our product.
If you have lost the Owner’s Manual, please contact the local agent or visit
copy of the owner's manual.
For proper operation, please read and keep this manual carefully.
AIR CONDITIONER
Model: IWAR90G IWAR120G


CONTENTS
Thank you for choosing FUJIDENZO air conditoner.Our design is based on the best
efficiency and the lowest noise operation and it can keep the room comfortable.
Please read this operating manual carefully before operating the unit and keep it
for consultation.
Structure mechanism and Installation
The Refrigerant
The images used in this manual may have a slight difference from the actual
product's appearance, please check the actual product for reference.
1
Function 3
Precautions 2
Power requirement 4
Installation 5
Notes for installation 8
Operation procedure
9
Air direction adjustment 9
10
Remote control panel
Remote control operation procedure
15
Operation Tips 16
Care and maintenance
Caution 17
Care and maintenance 19
Troubleshooting guide 20
After service 21
22
Please read this operating manual carefully before operating the unit.

- 1-
The Refrigerant
●To realize the function of the air conditioner unit, a special refrigerant circulates
.
leads to explosion
. It can
● Compared to common refrigerants, R32 is a nonpolluting refrigerant with no
lower. R32 has got very good thermodynamic features which lead to a really high
WARNING:
Do not use means to accelerate the defrosting process or to clean, other than
those recommended by the manufacture.Should repair be necessary, contact your
nearest authorized Service Centre.
The appliance shall be stored in a room without continuously operating ignition
electric heater.)
Do not pierce or burn.
than 4m .
2
’s
instructions only.
Be aware that refrigrants not contain odour.
Read specialist’s manual.

- 2 -
electric shock.
Please contact dealer when you need to repair air conditioner.
injury or damage.
sensory or mental capabilities, or lack of experience and knowledge, unless they
have been given supervision or instruction.
● Do disconnect power supply when cleaning air conditioner. Otherwise, it may cause
● Do not repair air conditioner by yourself. It may cause electric shock or damage.
● Maintenance must be performed by qualified professionals.Otherwise,it may cause
● The appliance is not to be used by persons (including children) with reduced physical,
● Children being supervised not to play with the appliance.
Please install the devices for short-circuit protection and electrical leakage protection
According to the local safety regulations, use qualified power supply circuit and circuit
when installing the air conditioner.
breaker.
Working temperature range
※ Operating Temperature Range
Indoor side DB/WB(°C)
Maximum cooling 32/23 43/-
Maximum heating 27/- 24/18
Outdoor side DB/WB(°C)
The operating temperature range (outdoor temperature) for cooling only unit is
18°C~ 43°C; for heat pump unit is -7°C~ 43°C.
Precautions
This appliance is not intended for use by persons (including children) with reduced
physical, sensory or mental capabilities, or lack of experience and knowledge,unless
they have been given supervision or instruction concerning use of the appliance
by a person responsiblefor their safety. Children should be supervised to ensurethat
they do not play with the appliance.
Children shall not play with the appliance.
Cleaning and user maintenance shall not be made by children without supervision.
Warning
The air conditioner should be installed in accordance with national wiring regulation.
Air Conditioner should be properly grounded. Incorrect grounding may cause electric
shock.
hazard.
broken.
injury or damage.
personal injury.
● Do not connect air conditioner to multi-purpose socket.Otherwise, it may cause fire
● Do install the air switch. If not, it may cause malfunction.
● Do not spill water on the remote controller’otherwise the remote controller may be
● Do not spray water on air conditioner. It may cause electric shock or malfunction.
● Do not extend fingers or objects into air inlet or air outlet. It may cause personal
● Do not step on the air conditioner, or put heavy objects. It may cause damage or
● Do not block air outlet or air inlet. It maycause malfunction.

- 3 -
Function
Introduction
This window-type room air conditioner from
FUJIDENZO can regulate the room temperature
and dry the room. It is convenient for your work,
study and life. It can be widely used in residence,
so on.
Room
temp.
Spring Autumn
Winter
Wind
direction
Summer
Cooling in summer
Exchange fresh air
Heating in winter
(Only for heat unit)
Dehumidifying in rainy or
humid season
In hot summer, Air conditioner can
cool down theroom air by transferring
heat out.
Without reducing the room temp., air
conditioner can dehumidify and make
the room air dry and comfortable.
Dry
In cold winter, Air conditioner can
heat up room air.
Open storm door to keep the fresh
air in the room.
Fresh Air

- 4 -
Power requirement
Rated voltage :230V~ 60Hz
●The electric components will be damaged when
the voltage is too high. If the voltage is too low,
the compressor will vibrate violently and may
damage the cooling system along with other
electrical components.
To ensure the reliable earthing, please do not connect earth
wire to the following places:
Earth wire
Water pipe
The ground must be connected.
● Special socket must be used. Furthermore, the
socket and wiring must conform to the wiring
regulations. And the earthing method must be
reliable.
protection switch of enough power capacity
and air switch with enough space.

- 5 -
Installation
Installation precaution:
Window type conditioner is so valuable and the
improper installation of it will cause a lot of da-
mage! Please call an authorized technician
to install the unit and don’t install it by yourself. Otherwise, we are not
responsible for the damage like this.
Location:
●The condensation water must be drained away conveniently.
●Install air conditioner unit far away from TV set or radio etc. to avoid distur-
bing video or voice.
●In salt and coastal area or place where is near thermal springsand polluted
by sulphurous gas, or other special areas, please contact the seller before
use.
●Avoid other heat sources or direct sun light.
●Avoid a place where is easy for children to touch.
●
Don't use the unit in the immediate surrondings of a laundry,a bath,a shower
or a swimming pool.
● For window type air conditioner with remote control, do not install in a
location where is strong electromagnetic disturbance, you should contact
the seller in advance to avoid the malfunction in use.
How to install:
●
Choose a location where there are
no any obstacle surrounding the
unit, and the plug is accessible.
● Prepare the installation hole slig-
htly bigger than unit size.
● Choose the installation space ac-
cording to the following diagram.
Over
1500 mm
The distance of obstructions from
window unit inside should be upper
300mm, lower 1500mm, left 500mm,
right 500mm, front 1500mm.
500mm 500mm
300mm
300mm

- 6 -
Installation procedure:
1) Remove the sticker from the front panel.
3) Fill up gaps in the cabinet with sponge
or foam.
2) Put the unit into the installation hole.
● When installing the unit, it should be sl-
anted down to the back to prevent loud
noise or vibration(Slant between 6-10mm.)
(Shown at right figure.)
● The installation place should be strong
enough to prevent loud noise or vibration.
6~10mm
Horizontal line
Installation assistance:
● Use iron support
The installation hole should be stro-
ng enough to support the air condit-
ioner.
If it cannot, iron support has to
be used
outdoors. Iron support sho-
● Use sunshade board
Air conditioner should avoid anything
to be dropped into it and avoid direct
sunshine. If there is no cover on it,
you should contact the seller for inst-
alling the sunshade board. When in-
stalling the sunshade board, don’t let
it block the air inlet at the side grille.
Wall
Wooden
frame
Sunshade
board
Rubber
plate
6~10mm
Support
Horizontal line

- 7-
Drain water :
Drain pan and drain hose need to be installed before using. Drain hose is
not included in the products, you need to purchase it locally to satisfy your
particular needs. Use the following procedure to install drain pan and drain
hose.
1. Slide out the chassis from the cabinet.
2. Install the drain pan to the corner of the cabinet with 2 screws.
3. Connect the drain hose to the outlet on the drain pan bottom.
4. Slide the chassis into its original place in the cabinet.
To get the maximum cooling efficiency , the air conditioner is designed to
splash the condensation water on the condenser coil . If the splashing sound
annoy you , you can remove the rubber plug from the chassis to lower the
noise, which also cause a bit loss of performance.
This manual suits for next models
1
Table of contents
Other FUJIDENZO Air Conditioner manuals
Popular Air Conditioner manuals by other brands

Fujitsu
Fujitsu ASYG 09 LLCA installation manual

York
York HVHC 07-12DS Installation & owner's manual

Carrier
Carrier Fan Coil 42B Installation, operation and maintenance manual

intensity
intensity IDUFCI60KC-3 installation manual

Frigidaire
Frigidaire FAC064K7A2 Factory parts catalog

Sanyo
Sanyo KS2432 instruction manual

Mitsubishi Electric
Mitsubishi Electric PUHZ-RP50VHA4 Service manual

Panasonic
Panasonic CS-S18HKQ Service manual

Panasonic
Panasonic CS-E15NKE3 operating instructions

Gree
Gree GWH18TC-K3DNA1B/I Service manual

Friedrich
Friedrich ZoneAire Compact P08SA owner's manual

Daikin
Daikin R32 Split Series installation manual