FUJIDENZO FVR-2000SC User manual

FVR-2000SC
FujidenzoAutomatic
Voltage Regulator
Please read the operation manual carefully so you can
conveniently and correctly use the product.
8
WARRANTY
TERMS AND CONDITIONS:
Any defect affecting the functionality of the appliance and which occurs
within one (1) year of its purchase will be repaired free of charge provided
the appliance has been used and maintained in accordance with the
instructions and has not been abused or used improperly in any way.
The warranty shall not cover defects resulting from any of the following:
•Normal wear and tear and improper use of the unit and nonadherence to
prescribed instruction for the normal operation and maintenance of the
unit.
•Improper fuses, faulty electrical circuitry of the customer’s place.
•Operating the unit outside the specified voltage range.
•Negligence, tampering and/or unauthorized repair of the unit.
•Damages caused by insects/rodents, accidents, fire, flood or other acts of
God.
•Development of rust/stains/cracks in any part of the body that is a normal
consequence of operation.
The warranty is void, if the serial number of the unit is removed, altered or
defaced.
If the warranty applies, proof of purchase (e.g. sales invoice or delivery
receipt) must be presented to the authorized service center for verification.
EXATECH, INC. and/or its authorized service center will exercise its best
efforts in performing the services covered by the warranty, but will not be
liable for damages, direct or otherwise arising out of delays or failure in
furnishing parts or services caused by acts of God, acts of Government
(National, Provincial or Local), labor disputes or difficulties, failure of
transportation or other causes beyond its control, or for damages resulting
from delays in performing services covered by this warranty
In line with our policy of continuous product development we reserve the
right to change the product, its packaging or documentation without prior
notice.

•Do not plug in nor unplug with wet hands.
•Plug the power cord correctly and push it tight in a wall socket.
•Never alter the appliance. Also, do not disassemble or repair by
yourself.
•AVR can be used by persons with reduced physical, sensory or
mental capabilities or lack of experience and knowledge if they have
been given supervision or instruction concerning use of the appliance
in a safe way and if they understand the hazards involved. Children
shall not play with the appliance. Cleaning and user maintenance shall
not be made by children without supervision. This appliance shall not
be used by children. Keep the appliance and its cord out of reach of
children.
•If the supply cord is damaged, it must be replaced by the manufacturer
service or similarly qualified person in order to avoid hazard.
•When the power cord, wire was broken or damaged or the plug-in part
become loose, do not operate it.
•The AVR can’t be immersed in water or any other liquid. Do not
operate with wet hands.
•Never disassemble the chamber set during operation or insert fingers,
foreign objects such as forks, spoons, etc into the AVR outlet.
•Place the unit on a flat and stable surface.
•Always unplug the AVR after use. Always disconnect the unit from the
supply if it is left unattended and before assembling, disassembling or
cleaning. When unplugging the power cord, make sure to hold the
power cord.
•Missuse of the unit can likely lead to injury.
•Outdoor use can be dangerous.
•Never let the unit operate unattended.
•Keep this manual after reading for future use.
SAFETY GUIDELINES
First of all, thank you for choosing the FUJIDENZO AUTOMATIC
VOLTAGE REGULATOR.
Please read this manual carefully before using the device. Please
keep the manual for future use. This guide is designed to help you
fully maximize the use of the product.
This equipment implements the trade standard of CE
TABLE OF CONTENTS
Safety Guidelines 1
Safety Instructions 2
Technical Characteristics
-Output Capability 3
-Output Capacity 3
- Synchronously Output 220V and 110V 3
- Overload or Short-circuit Protection 3
- Fan Heat Dispersion Function 3
- Over-voltage Protection 4
- Under-voltage indicator 4
- Long-time Delay 4
- Short-time Delay 5
-Applicable Working Conditions 5
Working Principle 5
Operating Instruction 6
Technical Specification 7
Warranty 8
1

SAFETY INSTRUCTIONS TECHNICAL CHARACTERISTICS
32
1. Please place the voltage regulator in a dry environment where is no
corrosive gas, explosive gas , conductive dust or steam, and the children
can't touch it, besides, it mustn't subject to the sunshine or rain.
2. The earth terminal must be firm and reliable to ensure safety.
3. The voltage regulator will produce little heat when it works normally, it is
not allowed to cover with any things, otherwise, it would be damaged for
not sufficient heat emission.
4. The fluctuation of external voltage that leads the equipment regulates
the voltage automatically, it is normal that there is the friction sound
from gear.
5. Choose input and output leads with suitable sectional area according to
the power of voltage regulator, try to reduce power consumption in the
circuit, in general, 5A/mm2 for copper wire, and reduce half for
aluminum wire.
6. The earth wire and neutral wire shall not be connected inversely, and the
earth wire can't take the place of neutral wire, otherwise, it would cause
the equipment body produces electricity or it can't work normally.
7. When the voltage regulator is energized, it is forbidden to open the case
for adjusting randomly, in order to prevent the electric shock.
8. In case that the frequency of generation power grid is unstable, but the
electricity is needed urgently, user can use the function of directly
providing commercial power, to protect the equipment against damage
for unstable frequency.
9. When the equipment has been used for a long time, a professional
electric worker shall be invited to clear away the dust in the machine
regularly to keep the clean between carbon brush and coil grinding
surface, and adjust the contact pressure between them to get a fine
contact against flashover; if the carbon brush is worn seriously, please
change it in time, to prevent the equipment being damaged.(Please
repair the voltage regulator and change the parts in the case that the
power is cut off.)
10. If the equipment works abnormally, user shall cut off the power
immediately and send it to the designated place for maintenance, if the
safety parts for maintenance or change are not provided by authorized
personnel, we won't be responsible for any possible safety quality
problems.
1. Output Capability - when the main voltage is lower than 198V, the
output capacity of this equipment reduces accordingly; when the output
voltage is 110V, its output capacity can’t exceed 50% of rated capacity.
The relationship between output capability and input voltage can be
seen on Diagram 1 and Diagram 2.
2. Output Capacity - when the input voltage of this equipment changes
from 140V to 260V (500VA-10kVA), its overload capability is shown on
diagram 1 and diagram 2 under emergency service. (P=Output Capability;
Pc=Rated Output Capability; U=Input Voltage)
3. Synchronously Output 220V and 110V - can output 110V and 220V at
the same time.
4. Overload or Short-circuit Protection –use circuit breaker to protect
against overload or short-circuit.
5. Fan Heat Dispersion Function –the fan is controlled by the temperature
control device, when the equipment’s inner sampling temperature
reaches 50°C-55°C or above, the fan will automatically turn on to
disperse the heat. If it doesn’t reach this temperature, the fan will turn
off.

TECHNICAL CHARACTERISTICS TECHNICAL CHARACTERISTICS
6. Over-voltage Protection –if the input voltage range exceeds its standard
range, the regulator cannot keep output voltage steady. When output
voltage exceeds 246±4V, the other voltage light will turn on, the delay
light on after 5±2 s, relay of PCB board disconnect, there is no output
voltage; the over-voltage light out when the voltage back to normal, then
delay light out, the relay of PCB board pull in, the stabilizer back to
normal output voltage.
NOTE: If users find that the Over-Voltage indicator keeps turning on even
when the input voltage range is normal, please stop using the equipment and
bring it to the nearest authorized service center to have it checked.
7. Under-voltage indicator –if the input voltage range exceed its standard
range, the regulator cannot keep output voltage steady. When the
output voltage is lower than 184±4V, the under-voltage light will turn on
which shows that the regulator is in under-voltage. Users should turn off
the regulator until the input voltage range is back to normal.
Note: If users find that the under-voltage indicator keeps turning on even
when the input voltage range is normal, please stop using the equipment and
bring it to the nearest authorized service center to have it checked.
8. Long-time Delay –turn off the “Delay Time Selector” switch, the
stabilizer is under long-time delay. The normal work light on when it is
power on, the delay light out after 5± 2min, then the stabilizer starts to
output. When in the state of Over-voltage protection and Under-voltage
indication, it also takes 5 ± 2 min for the delay light out in long-time
delay mode, then the stabilizer back to normal output voltage.
Note: If the stabilizer load is followed by refrigerators, air conditioners and
other appliances, the internal air compressor cannot be continuous power
on, otherwise it will cause damage to such compressor, it is suggested to
choose long-time delay mode.
54
9. Short-time Delay –turn on the “Delay Time Selector” button switch, the
stabilizer is under short-time delay. The Normal work light on when it is
power on, the delay light out after 5±2 s, then the stabilizer starts to
output. When in the state of Over-voltage protection and Under-voltage
indication, it also takes 5 ±2 s for the delay light out in short-time delay
mode, then the stabilizer back to normal output voltage .
10. Applicable Working Conditions
-Environment temperature : -5°C ~ +40°C
-Relative Humidity : less than 95% (25°C)
-Air Pressure : 86-106kPa
- Working Environment : no chemical deposition, scale,
harmful corrosive medium as well as flamable or
explosive gas. Besides, the altitude is not higher than 1km.
WORKING PRINCIPLE
Circuit Diagram
NOTE: the following diagram is only for reference, if changed partially for
improving the product, we won’t notice separately.

OPERATION INSTRUCTION TECHNICAL SPECIFICATION
76
1. Before operating, please make sure the voltage of power network is
within the range of input voltage permitted by this equipment, then
connect the wires according to the symbol on front and back panel
carefully and do not make mistake, make sure firm grounding .( Input
wire of voltage regulator of single - 500VA ~5KVA is power line)
2. Turn on the power switch of the voltage regulator, the output voltage
indication of single -phase voltage regulator shall be 220V.
3. When single - phase voltage regulator outputs 220V and 110V at the
same time, the sum of load current can't exceed the rated value.
4. If the mains voltage is lower than198V (see diagram1 and diagram 2):
please use it through reducing the power referring to curve of output
capacity.
5. When it is inductive load (such as air - conditioner and refrigerator), as
the starting current of inductive load is very heavy, please choose
voltage regulator whose output capacity is 3-5 times of load power. For
other capacitive loads, please leave enough allowance for output
capacity of voltage regulator.
6. After the voltage regulator is not used, please turn off the power switch
of consumer first, then the power switch of voltage regulator.
7. When mains failure happens (include loss of phase) or the input voltage
is too high, please turn off the voltage regulator and the power switch of
consumer in time.
Product Name: Fujidenzo Automatic Voltage Regulator
Model No.: FVR2000SC
Rated Input Voltage: 140V a.c. ~ 263V a.c.
Output Voltage: 110V a.c. ~ 220V a.c.
Accuracy of Voltage
Stabilization: 220V±3%, 110V±6%
Over-voltage Protection Value
246±4V
Under-voltage Indication
Value: 184±4V
Frequency: 50~60Hz
Waveform Distortion: No additional waveform distortion
Load Power Factor: 0.8
Efficiency: ≥90%
Adjusting Time: ≤1.5s (when the input voltage has a
change of 10%)
Time Delay: Long-time delay: 5±2mins;
Short-time delay: 5±s
Enclosure Protection Degree: IP20
Insulation Thermal Endurance
Class: Class B
Electric Strength: No flashover or breakdown at 2000V/min
Insulation Resistance: ≥5MΩ
Table of contents
Popular Controllers manuals by other brands

IDEC
IDEC SmartAXIS Touch FT1A Series user manual

TECO-Westinghouse
TECO-Westinghouse EQ7 Series instruction manual

Broadcom
Broadcom BROADCOM HT1000 user manual

Precision Digital Corporation
Precision Digital Corporation Helios PD2-6310-7H7 instruction manual

Siemens
Siemens Simatic S7-300 manual

V2
V2 STARK3-230V instruction manual