Contents
Control of Electric Backups . . . . . . . . . . . . . . 4 Sensor and Input Test Mode . . . . . . . . . . . . .4
Fault. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
Fault List. . . . . . . . . . . . . . . . . . . . . . . . 5
Hydraulic Unit Fault. . . . . . . . . . . . . . . 5
Outdoor Unit Fault . . . . . . . . . . . . . . .7
Outdoor Unit Clearing . . . . . . . . . . . . . . . . . 8
Failures with Error Code . . . . . . . . . . . .8
Failures With No Error Code . . . . . . . . . 28
Sensor Values . . . . . . . . . . . . . . . . . . . . 32
Outdoor Unit Temperature Sensors. . . . . . 32
Hydraulic Unit Temperature Sensors . . . . . 32
Service parts information . . . . . . . . . . . . . . 33
Service parts information 1 : Compressor . .33
Service parts information 2 : Inverter compressor
33
Service parts information 3 : Outdoor unit
electronic expansion valve (EEV). . . . . . . 34
Service parts information 4 : Outdoor unit
solenoid valve (SV) . . . . . . . . . . . . . . 35
Service parts information 5 : Outdoor unit fan motor
36
Service parts information 6 : Active lter module
(Only for WO*A080LFCAand WO*A100LFTAmodels)
36
Service parts information 7 : IPM
(mounted on Transistor PCB, Only for
WO*A080LFCA and WO*A100LFTA models) 37
Operating Limits . . . . . . . . . . . . . . . . . . . 38
Failures . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 39
Hydraulic, Electric and Refrigeration Systems . . .39
Hydraulic System . . . . . . . . . . . . . . . 39
Electrical System . . . . . . . . . . . . . . . 40
Refrigeration System . . . . . . . . . . . . . 41
Compressor Operating Checks . . . . . . . . . . . 43
Refrigeration Circuit Leak Test . . . . . . . . . . . 43
Troubleshooting . . . . . . . . . . . . . . . . . . . 43
Control and test . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4
"
This device requires for its installation, the intervention of qualied personnel with a certicate of
capacity for handling refrigerants.
Control Settings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 44
General . . . . . . . . . . . . . . . . . . . . . . .44
Function Table. . . . . . . . . . . . . . . . . . . . 45
Adjustment Function Details. . . . . . . . . . . . . 61
Date and Time Functions. . . . . . . . . . . 61
User Interface Functions . . . . . . . . . . . 61
Time Program Functions (heating circuit 1 & 2,
DHW, cooling) . . . . . . . . . . . . . . . .62
Heating Circuit 1 & 2 Functions. . . . . . . . 63
Cooling Circuit 1 Function . . . . . . . . . .70
DHW Functions (with DHW kit
or with integrated DHW models). . . . . . . . . . . 74
Swimming Pool Functions . . . . . . . . . .75
Heat Pump Functions. . . . . . . . . . . . . 75
Supplementary source . . . . . . . . . . . . 77
DHW Tank Functions (with DHW kit or with
integrated DHW models) . . . . . . . . . . . 78
Conguration Functions . . . . . . . . . . . 79
Error Functions . . . . . . . . . . . . . . . . 80
Maintenance / Special Operating Mode Functions
83
Input / Output Testing Functions . . . . . . . 85
Status Functions . . . . . . . . . . . . . . . 86
Generator Diagnosis Functions. . . . . . . . 88
Consumer Diagnosis Functions . . . . . . .88
Domestic Hot Water (with DHW kit or with
integrated DHW models) . . . . . . . . . . . 89
Hydraulic checks . . . . . . . . . . . . . . . . . .91
Maintenance of the DHW tank (Integrated DHW models)
91
Emptying the hot water tank . . . . . . . . . 91
Descaling . . . . . . . . . . . . . . . . . . . 91
Checking the outdoor unit . . . . . . . . . . . . . . 91
Electrical checks. . . . . . . . . . . . . . . . . . . 91
Maintenance services . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 91
Maintenance document "1792 - EN"
Split system single phase type
- 2 -
(Only for WOYA080LFCAand WOYA100LFTA models)
WOYA080LFCA and WOYA100LFTA models)