Contents
1
Control and test ..............................................................................................................4
1.1 Control of Electric Backups....................4 1.2 Sensor and Input Test Mode.................4
2
Faults...............................................................................................................................5
2.1 Fault List................................................5
2.1.1
Hydraulic Unit Fault ......................................5
2.1.2
Outdoor Unit Fault ........................................7
2.2 Outdoor Unit Clearing............................8
2.2.1
Failures with Error Code...............................8
2.2.2
Failures With No Error Code.......................27
2.3 Sensor Values .....................................31
2.3.1
Outdoor Unit Temperature Sensors ...........31
2.3.2
Hydraulic Unit Temperature Sensors .........31
2.4 Service parts information .....................32
2.4.1
Service parts information 1 : Compressor..32
2.4.2
Service parts information 2 : Inverter
compressor .................................................33
2.4.3
Service parts information 3 : Outdoor unit
electronic expansion valve (EEV)................34
2.4.4
Service parts information 4 : Outdoor unit
solenoid valve (SV)......................................35
2.4.5
Service parts information 5 : Outdoor unit fan
motor............................................................35
2.4.6
Service parts information 6 : Active filter
module (Only for WO*A080LDC and
WO*A100LDT models)................................36
2.4.7
Service parts information 7 : IPM (mounted
on Transistor PCB, Only for WO*A080LDC
and WO*A100LDT models).........................37
2.5 Operating Limits.................................. 38
3
Failures..........................................................................................................................39
3.1 Hydraulic, Electric and Refrigeration
Systems...............................................39
3.1.1
Hydraulic System........................................39
3.1.2
Electrical System ........................................ 40
3.1.3
Refrigeration System..................................41
3.2 Compressor Operating Checks........... 43
3.3 Refrigeration Circuit Leak Test............ 43
3.4 Troubleshooting .................................. 43
4
Control Settings............................................................................................................44
4.1 General................................................44
4.2 Function Table.....................................45
4.3 Adjustment Function Details ................51
4.3.1
Date and Time Functions............................51
4.3.2
User Interface Functions.............................51
4.3.3
Time Program Functions (heating circuit 1 &
2, DHW, cooling).........................................52
4.3.4
Heating Circuit 1 & 2 Functions..................53
4.3.5
Cooling Circuit 1 Functions.........................60
4.3.6
DHW Functions (with DHW kit or with
integrated DHW models).............................66
4.3.7
Swimming Pool Functions ..........................69
4.3.8
Heat Pump Functions..................................69
4.3.9
Supplementary source ................................71
4.3.10
DHW Tank Functions (with DHW kit or with
integrated DHW models).............................73
4.3.11
Configuration Functions..........................75
4.3.12
Error Functions .......................................77
4.3.13
Maintenance / Special Operating Mode
Functions.................................................79
4.3.14
Input / Output Testing Functions.............81
4.3.15
Status Functions .....................................82
4.3.16
Generator Diagnosis Functions ..............87
4.3.17
Consumer Diagnosis Functions..............88
5
Maintenance services...................................................................................................91
5.1 Hydraulic checks..................................91
5.2 Maintenance of the DHW tank
(Integrated DHW models).....................91
5.2.1
Emptying the hot water tank.......................91
5.2.2
Descaling.....................................................91
5.3 Checking the outdoor unit.................... 91
5.4 Electrical checks ................................. 91
6
Maintenance (integrated DHW models........................................................................92
6.1 Emptying the hydraulic unit..................92
6.2 Distribution valve .................................92
6.3 ACI check............................................ 92