- (OU01 - 07) - Outdoor unit / Single phase
OUTDOOR UNIT
WOA060-100LF
OUTDOOR UNIT
WOA060-100LF
PRODUCT INFORMATION2-4.
Product information according to Commission Delegated Regulation (EU) 813/2013
Product information is based on the average climate condition.
Model Hydraulic unit WSYA050DG6
WSHA050DG *1 WGYA050DG6
WGHA050DG *1 WSYA100DG6
WSHA100DG *1 WGYA100DG6
WGHA100DG *1
Outdoor unit WOYA060LFCA
WOHA060LFCA WOYA060LFCA
WOHA060LFCA
Air-to-water heat pump Yes
Water-to-water heat pump No
Brine-to-water heat pump No
Low-temperature heat pump No
Equipped with a supplementary heater Yes
Heat pump combination heater Yes
Temperature application °C 55
35
55
35
55
35
55
35
Rated heat output *2
Prated
kW44445555
Seasonal space heating energy efciency ƞs% 115 169 115 169 115 169 115 169
Declared capacity for heating for part load at indoor temperature 20 °C and outdoor temperature Tj
Tj= –7 °C Pdh kW 3.8 4.0 3.8 4.0 4.0 4.6 4.0 4.6
Tj= +2 °C Pdh kW 2.3 2.4 2.3 2.4 2.5 2.8 2.5 2.8
Tj= +7 °C Pdh kW 1.7 2.0 1.7 2.0 1.7 2.3 1.7 2.3
Tj= +12 °C Pdh kW 2.1 2.3 2.1 2.3 2.1 2.3 2.1 2.3
Tj= bivalent temperature Pdh kW 3.8 4.0 3.8 4.0 4.0 4.6 4.0 4.6
Tj= operation limit temperature Pdh kW 3.2 3.9 3.2 3.9 3.5 4.5 3.5 4.5
Tj= –15 °C (if TOL < –20 °C) Pdh kW - - - - - - - -
Bivalent temperature Tbiv °C -7 -7 -7 -7 -7 -7 -7 -7
Cycling interval capacity for heating Pcych kW Not applicable
Degradation co-efcient *3 Cdh — 0.9 0.9 0.9 0.9 0.9 0.9 0.9 0.9
Declared coefcient of performance or primary energy ratio for part load at indoor temperature 20 °C and outdoor temperature Tj
Tj= –7 °C
COPd
— 1.86 2.86 1.86 2.86 1.79 2.65 1.79 2.65
Tj= +2 °C
COPd
— 2.82 4.10 2.82 4.10 2.86 4.17 2.86 4.17
Tj= +7 °C
COPd
— 4.00 5.90 4.00 5.90 4.03 5.99 4.03 5.99
Tj= +12 °C
COPd
— 5.84 8.12 5.84 8.12 5.84 8.29 5.84 8.29
Tj= bivalent temperature
COPd
— 1.86 2.86 1.86 2.86 1.79 2.65 1.79 2.65
Tj= operation limit temperature
COPd
— 1.54 2.65 1.54 2.65 1.56 2.57 1.56 2.57
Tj= –15 °C (if TOL < –20 °C)
COPd
—--------
Operation limit temperature TOL °C -10 -10 -10 -10 -10 -10 -10 -10
Cycling interval efciency
COPcyc
— Not applicable
Heating water operating limit temperature
WTOL
°C 55 55 55 55 55 55 55 55
Power consumption in modes other than active mode
Off mode POFF kW 0.006 0.006 0.006 0.006 0.006 0.006 0.006 0.006
Thermostat-off mode PTO kW 0.016 0.019 0.016 0.019 0.016 0.023 0.016 0.023
Standby mode PSB kW 0.010 0.010 0.010 0.010 0.010 0.010 0.010 0.010
Crankcase heater mode PCK kW 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
Supplementary heater
Rated heat output *2 Psup kW 1.1 0.6 1.1 0.6 1.0 0.7 1.0 0.7
Type of energy input Electric
Other items
Capacity control Variable
Sound power level Indoor unit LWA dB 46 46 46 46 46 46 46 46
Outdoor unit LWA dB 65 60 65 60 65 63 65 63
Emissions of nitrogen oxides NOx
mg/kWh
Not applicable
Rated air ow rate Outdoor unit — m³/h 2070 1700 2070 1700 2070 2070 2070 2070
Declared load prole - - L L - - L L
Daily electricity consumption Qelec kWh - - 4.000 4.000 - - 4.000 4.000
Water heating energy efciency ηwh % - - 120 120 - - 120 120
Daily fuel consumption Qfuel kWh Not applicable
Contact details FUJITSU GENERAL (EURO) GmbH
Werftstraße 20, D-40549 Düsseldorf, F. R. Germany
*1 : Optional electrical back up heater consumption is taken into account in the performance calculation.
*2 : For heat pump space heaters and heat pump combination heaters, the rated heat output Prated is equal to the design load for heating
Pdesignh, and the rated heat output of a supplementary heater Psup is equal to the supplementary capacity for heating sup (Tj).
*3 : If Cdh is not determined by measurement then the default degradation coefcient is Cdh = 0.9.