Questions? Call(315) 298-5121,or visitus onlineat www.fulton.com
PHW-IOM-2013-0214 TABLE OF CONTENTS
0-1
Introduction 1-1
Overview.............................................................................................................. 1-2
Warnings & Cautions............................................................................................ 1-2
Disclaimers and Local Codes ................................................................................ 1-2
Installation 2-1
Product Overview................................................................................................. 2-2
Review Shipment Contents.................................................................................. 2-2
Placement & Rigging........................................................................................... 2-3
Clearances and Serviceability .............................................................................. 2-5
Install Isolation Mounts ....................................................................................... 2-5
HOWTO INSTALL ELASTOMER CUBE ISOLATION MOUNTS........................................................25
HOWTO INSTALL SPRING ISOLATION MOUNTS.........................................................................26
HOWTO INSTALL SEISMIC SPRING ISOLATION MOUNTS...........................................................27
Install BoilerTrim ................................................................................................. 2-8
Water Chemistry Requirements........................................................................... 2-8
Install Water Piping.............................................................................................. 2-9
Install Condensate Drain.................................................................................... 2-11
INSTALL CONDENSATE DRAIN PIPING .....................................................................................212
Install pH Neutralization Kit............................................................................... 2-12
Install Gas Piping................................................................................................ 2-14
Install FieldWiring ............................................................................................. 2-14
Air Intake Supply Piping Installation Preparation.............................................. 2-15
CEMENTING JOINTS...................................................................................................................216
Install Intake Muer ......................................................................................... 2-17
Preparing to Install ExhaustVent Piping............................................................ 2-17
Exhaust Muer Installation .............................................................................. 2-18
Air Intake & Exhaust Piping Requirements for the Pulse Boiler ........................ 2-19
Air Intake Supply and ExhaustVent Installation ............................................... 2-20
VerticalVent Flashing and Installation .............................................................. 2-21
VerticalVent Termination .................................................................................. 2-21
Horizontal InstallationWall Penetrations ......................................................... 2-24
WallThimble Installation .................................................................................. 2-24
HorizontalVentTermination ............................................................................. 2-25
After Installation/Prior to Start-Up.................................................................... 2-26
Installation Checkpoints ................................................................................... 2-28
Testing Ignition Safety Shut O ........................................................................ 2-28
Measure Gas Flow Rate ..................................................................................... 2-28
TO CORRECT INPUT ADJUST GAS PRESSURE REGULATOR....................................................229
Rating the Boiler................................................................................................ 2-29
To Check for High Gas Pressure .......................................................................... 2-29
For High Gas Pressure Installations Using Fisher Regulators ............................. 2-29
Before Leaving the Installation ......................................................................... 2-30
Operation 3-1
Before Start Up..................................................................................................... 3-2
Start Up................................................................................................................ 3-2
LINKAGE ADJUSTMENT FOR PULSE MODULATED BOILERS.......................................................33
IFTHE BOILER DOESN’T START ..................................................................................................35
Sequence of Operation for Modulated Pulse Hydronic Boilers............................ 3-6
General Operation of the Boiler ........................................................................... 3-6
Programming Instructions for the SOLA Control ................................................. 3-6
CHANGING/TESTING SOLA HIGH LIMIT SETPOINT ..................................................................310
VERIFYING CHANGESTO HIGH LIMIT SETPOINT .....................................................................310
ACCESSING LOCKOUT HISTORY AND CLEARING LOCKOUTS.....................................................311
PROCEDURE FOR REMOTE FIRING RATE USING A 420MA SIGNAL SINGLE BOILER ...........312
PROCEDURE FOR REMOTE SETPOINT USING A 420MA SIGNAL SINGLE BOILER................313
PROCEDURE FOR LEAD/LAG WITH OUTDOOR RESETWITH MULTIPLE BOILERS....................314
SINGLE BOILER OUTDOOR RESET PROGRAMMING..................................................................318
Third Party SOLA Control.................................................................................... 3-21
LEAD/LAG OUTDOOR RESET CONFIGURATION USING COMMUNICATION PORT 2..................321
STAND ALONE BOILERS CONTROLLED BY ATHIRD PARTY CONTROL......................................321
GATEWAYS .................................................................................................................................321
Maintenance 4-1
General................................................................................................................. 4-2
Daily Maintenance and Inspection Schedule ...................................................... 4-2
Monthly Maintenance and Inspection Schedule................................................. 4-2
Annual Maintenance and Inspection Schedule................................................... 4-3
After All Repairs and Maintenance ...................................................................... 4-4
Troubleshooting................................................................................................... 4-5
Reviewing Diagnostics on SOLA Control.............................................................. 4-6
TAKING SCREEN SHOTS................................................................................................................47
Warranty & Parts 5-1
Standard Warranty for Fulton Pulse Boilers
with Carbon Steel Exhaust Pipes.......................................................................... 5-2
Standard Warranty for Fulton Pulse Boilers
with Duplex Stainless Steel Exhaust Pipes........................................................... 5-3
Parts..................................................................................................................... 5-4