Receiver E1:
Dipswitch-Receiver OLP-E1 with 6 exits
Active emergency Stopp multiple-monitored
1 special channel, emergency stop exit
A new transmitter can be registered to an existing receiver without opening the devices.
Over 200 hours of operation without changing batteries
Range: about 250m
Dippswitches: DSx
•DS1 Dynamic start ( Transmitter starts automatically in case of radio connection break)
•DS2 Timeout = 1850 ms.
•DS3 Emergency Stopp relay switches on with radio connection
•DS4 FF-operation only button 7 (release winch) after 3s pressing; is reset by pull or release
winch
•DS5 With pressing button 4 (engine start), engine stop switches for 3s before engine start
•DS6 When pressing button 2 (radio on), the exit switches not before the user is repeatedly
pressing the button.
•DS7 No button interlocking button 3 – button 6
•DS8 Overload shutdown (4,5A per exit or 15A overall)
•DS9 Special channel switches with button 3
•DS10 Special channel switches with button 4
•DS11 Special channel switches with button 5
•DS12 Special channel switches with button 6
•DS13 Special channel switches with button 7
•DS14 Special channel switches with button 8
•DS15 FF – operation T7 and T8
•DS16 FF remember after radio connection break