Furuno CH-270 User manual

Installation Manual
LCD SEARCHLIGHT SONAR CH-270
SAFETY INSTRUCTIONS ......................... i
SYSTEM CONFIGURATION ................... iii
EQUIPMENT LISTS.................................. v
1. MOUNTING ......................................... 1
1.1 Display Unit, Control Unit ................... 1
1.1.1 General mounting
considerations ......................... 1
1.1.2 Mounting the FURUNO-supplied
display unit MU-100C .............. 2
1.1.3 System with locally supplied
monitor..................................... 6
1.2 Transceiver Unit ................................. 7
1.2.1 General mounting
considerations.......................... 7
1.2.2 Mounting procedure................. 7
1.3 Hull Unit.............................................. 8
1.3.1 General handling
considerations.......................... 8
1.3.2 Installation position
considerations.......................... 8
1.3.3 Mounting the retraction tank .... 9
1.3.4 Assembling and installation of
hull unit ...................................11
1.4 Control Box (for Hull Unit CH-184) ... 23
1.5 Interface Unit .................................... 24
1.6 Motion Sensor, Clinometer ............... 25
1.6.1 Motion sensor.......................... 25
1.6.2 Clinometer ............................... 26
2. WIRING.............................................. 27
2.1 Wiring Among Units...........................27
2.2 Transceiver Unit ................................32
2.2.1 Wiring inside the transceiver
unit..........................................32
2.2.2 Synchronizing transmission with
echo sounder or other sonar...33
2.3 Hull Unit.............................................34
2.4 Control Box (for Hull Unit CH-184) ....35
2.5 Interface Unit.....................................36
2.6 I/O Sentences....................................37
3. ADJUSTMENTS ................................ 38
3.1 Heading Alignment and Draft
Adjustments.......................................38
3.2 Using External KP (Keying Pulse).....40
3.3 Adjusting the Motion Sensor,
Clinometer.........................................42
3.4 System Backup .................................44
3.5 Setting of Interface Unit.....................46
APPENDIX Retrofitting CH-18/CH-28...47
PACKING LISTS
OUTLINE DRAWINGS
INTERCONNECTION DIAGRAMS
www.furuno.co.jp
All brand and
p
roduct names are trademarks
,
re
g
istered trademarks or service marks of their res
p
ective holders.

Thepaperusedinthismanual
iselementalchlorinefree.
・FURUNOAuthorizedDistributor/Dealer
9‑52Ashihara‑cho,
Nishinomiya,662‑8580,JAPAN
Telephone: +81‑(0)798‑65‑2111
Fax:
+81‑(0)798‑65‑4200
A
:
JUN
2003
.
PrintedinJapan
Allrightsreserved.
D
:
JUN
.
03,2010
Pub.No.
IME‑13220‑D
*00014699713**00014699713*
(
DAMI
)
CH‑270
*
00014699713
*
*
00014699713
*
*00014699713*

i
WARNING
ELECTRICAL SHOCK HAZARD
Do not open the equipment.
Only qualified personnel
should work inside the
equipment.
WARNING
Turn off the power at the switchboard
before beginning the installation.
Fire or electrical shock can result if the
power is left on.
Do not install the display unit or
transceiver unit where it may get wet
from rain or water splash.
Water in the equipment can result in fire,
electrical shock or damage the equipment.
Be sure no water leaks in at the
transducer installation site.
Water leakage can sink the vessel.
Also confirm that the transducer will not
loosen by ship's vibration.
The installer of the equipment is solely
responsible for the proper installation of the
equipment. FURUNO will assume no
responsibility for any damage
associated with improper installation.
Install the specified transducer tank
in accordance with the installation
instructions. If a different tank is to be
installed the shipyard is solely respon-
sible for its installation, and it should
be installed so the tank doesn't strike
an object.
The tank or hull may be damaged if the
tank strikes an object.
SAFETY INSTRUCTIONS

ii
CAUTION
Observe the following compass safe
distances to prevent deviation of a
magnetic compass:
CH-252/
MU-100C
CH-273
Standard Steering
0.80 m 0.55 m
0.60 m 0.35 m
0.95 m 0.65 m
WORKING WITH THE SONAR OIL
Precautions
Keep oil away from eyes. Wear protective
goggles when working with the oil. The oil
can cause inflammation of the eyes.
Do not touch the oil. Wear protective
gloves when working with the oil. The oil
can cause inflammation of the skin.
Do not ingest the oil. Diarrhea or vomiting
can result.
Keep the oil out of reach of children.
Emergency
If the oil enters eyes, flush with clean
water about 15 min. Consult a physician.
If the oil contacts skin, wash with soap
and water.
If the oil is ingested, see a physician
immediately.
Disposal of oil and its container
Dispose of oil and its container in
accordance with local regulations.
For further details, contact place of
purchase.
Storage
Seal container to keep out foreign
material. Store in dark place.
CAUTION
Keep hands away from the raise/lower
shaft of the hull unit when it is working.
Injury to hands may result if they become
caught in the shaft.
During sea trials, do not exceed 20
knots when operating the equipment
and do not exceed 15 knots when
raising or lowering the transducer.
The transducer shaft may become
damaged.
Do not turn on the equipment with the
transducer exposed to air as this may
damage the transducer.
Do not swing the soundome by holding
the transducer cable.
The cable and soundome may become
damaged.
IF-8000

iii
SYSTEM CONFIGURATION
CH-270 (350 stroke)
HULL UNIT
SPEAKER
DATA/VIDEO OUT
MOTION SENSOR
12-32VDC
12-32 VDC
Speaker
Motion Sensor
External
Monitor
Control Unit
Display
Unit
Navigator
CONTROL UNIT CH-252
DISPLAY UNIT MU-100C
TRANSCEIVER UNIT
CH-273
INTERFACE UNIT
IF-8000
Remote
Controller
HULL UNIT
CH-181
12/24 VDC
Note 1: The CH-270 is supplied
with or without a display
unit. For connection of
locally supplied monitor, an
interface unit is provided.
The drawing above shows
the system configuration
with the MU-100C.
Note 2: For use of a locally
supplied monitor, connect
it and control unit to the
interface unit.
: Standard
: Option
: Local Supply

i
v
CH-270 (250 stroke)
HULL UNIT
SPEAKER
DATA/VIDEO OUT
MOTION SENSOR
12-32VDC
12/24 VDC
12-32 VDC
Speaker
Motion Sensor
External
Monitor
Control Unit
DIsplay Unit
Navigator DISPLAY UNIT MU-100C
TRANSCEIVER UNIT
CH-273
INTERFACE UNIT
IF-8000
Remote
Controller
: Standard
: Option
: Local Supply
CONTROL BOX
CONTROL UNIT CH-252
HULL UNIT
CH-184
Note 1: The CH-270 is supplied
with or without a display
unit. For connection of
locally supplied monitor, an
interface unit is provided.
The drawing above shows
the system configuration
with the MU-100C.
Note 2: For use of a locally
supplied monitor, connect
it and control unit to the
interface unit.

v
EQUIPMENT LISTS
Standard supply
Name Type Code No. Qty Remarks
Control Unit/
Display Unit CH-252/MU-100C — 1
System with FURUNO-supplied
monitor
Control Unit CH-252 — 1
Interface Unit IF-8000 — 1
System with locally supplied
monitor
Transceiver Unit CH-273 — 1
CH-181-270 — 350 stroke
Hull Unit CH-184-270 —
1 250 stroke
See table on next
page for hull units.
SP06-01201* 006-559-590 1 For Hull Unit
Spare Parts SP06-01102* 006-556-210 1
See page ix. 1 set Three types of cables
CP06-00403 006-573-730 1 set For CH-184-270
CP06-06600 000-012-474 1 For CH-252/MU-100C
CP02-06610 000-012-480 1 MJ-A10SPF0002-015
Installation
Materials
CP02-06620 000-012-481 1 MJ-A10SPF0002-050
Choose
either
one.
FP02-05101 000-012-474 FP06-01102*, FP02-05101*
For display unit
FP06-01120* 006-556-260
1 For system with locally supplied
monitor
Accessories
06-021-2121 100-320-101 1
Hard cover
For system with locally supplied
monitor
* See packing list at back of manual for details.

vi
Hull Unit (CH-181-270)
Specifications
Type Cable
Length
Shaft
Length Power Stroke
CH-181-1-11-24 2.4 m
CH-181-1-11-35 1.17 m
CH-181-1-22-35 3.5 m
CH-181-1-22-52 2.2 m
CH-181-1-38-52 5.2 m 3.8 m
12 VDC
CH-181-2-11-24 2.4 m
CH-181-2-11-35 1.17 m
CH-181-2-22-35 3.5 m
CH-181-2-22-52 2.2 m
CH-181-2-38-52 5.2 m 3.8 m
24 VDC
350 mm
Hull Unit (CH-184-270)
Specifications
Type Cable
Length
Shaft
Length Power Stroke
CH-184-1-11-52 5.2 m
CH-184-1-11-80 8 m
1.17 m
CH-184-1-22-52 5.2 m
CH-184-1-22-80 8 m
2.2 m
12 VDC
CH-184-2-11-52 5.2 m
CH-184-2-11-80 8 m
1.17 m
CH-184-2-22-52 5.2 m
CH-184-2-22-80 8 m
2.2 m
24 VDC
250 mm

vii
Hull Unit Shipped Configuration (CH-181-270)
Name Type Code No. Qty Remarks
CH-1811-1 — 12 VDC
Raise/Lower
Drive Assy. CH-1811-2 —
1 set 24 VDC
CH-1812-1-24 — 2.4 m
CH-1812-1-35 — 3.5 m
CH-1812-1-52 — 5.2 m
12 VDC
CH-1812-2-24 — 2.4 m
CH-1812-2-35 — 3.5 m
Train/Tilt Assy.
CH-1812-2-52 —
1 set
5.2 m
24 VDC
Soundome (D)
Assy. CH-1813 006-541-410 1
Main Body
Flange Assy. CH-1814 006-541-420 1 set Flange, Grease cotton
CH-1815-11 006-546-420 Shaft length 1.17 m
Assembling Kit
for Field CH-1815-22 006-546-430 1 set Shaft length
2.2 m/3.8 m
See
next
table
06-008-1021 100-028-501 1.17 m
SHJ-0006 661-000-062 2.2 m
Main Shaft
06-007-1572 600-715-721
1
3.8 m
Sonar Oil 4-liter can 000-824-033 1

viii
Hull Unit Shipped Configuration (CH-184-270)
Name Type Code No. Qty Remarks
CH-1841-1 — 12 VDC
Control Box CH-1841-2 —
1 set 24 VDC
CH-1842-1 —
Raise/Lower
Drive Assy. CH-1842-2 —
1 set See Raise/lower drive assy.
CH-1812-1-52 — 5.2 m
CH-1812-1-80 — 8 m
12 VDC
CH-1812-2-52 — 5.2 m
Train/Tilt Assy.
CH-1812-2-80 —
1 set
8 m 24 VDC
Soundome (D)
Assy. CH-1813 006-541-420 1
Main Body
Flange Assy. CH-1844 006-573-720 1 set Flange, Grease cotton
CH-1845-11 006-546-380 Shaft length 1.17 m
Assembling Kit
for Field CH-1845-22 006-546-410 1 set Shaft length 2.2 m
See
next
table
06-008-1021 100-028-500 1.17 m
Main Shaft SHJ-0006-1 661-000-061 1 2.2 m
Sonar Oil 4-liter can 000-824-033 1
Installation
Materials CP06-00403 006-573-730 1
For CH-184-270, includes
Ground plate WEA-1004
(Code No. 006-543-980)
Cable assy. 06S4054
(Code No. 000-122-879)

ix
Installation Materials
Specifications (Cable between units)
Type Code No.
Display Unit (or I/F Unit) ↔
Transceiver Unit
Transceiver
Unit ↔Hull
Unit
Crimp-on Lug
CP06-01300 000-068-593 06S4086*10m* CP06-01301*
CP06-01310 000-068-594 06S4086*15m* CP06-01301*
CP06-01320 000-068-595 06S4086*20m* CP06-01301*
CP06-01330 000-068-596
06S4078
*5m*
06S4086*30m* CP06-01301*
CP06-01340 000-068-597 06S4086*10m* CP06-01301*
CP06-01350 000-068-598 06S4086*15m* CP06-01301*
CP06-01360 000-068-599 06S4086*20m* CP06-01301*
CP06-01370 000-068-600
06S4078
*10m*
06S4086*30m* CP06-01301*
Control Unit Cable
Type Code No. Qty Remarks
CP02-06600* 000-012-486 1 MJ-A10SPF0002-0015, For system with
FURUNO-supplied monitor
CP02-06610* 000-012-480 MJ-A10SPF0002-015, 1.5 m
CP02-06620* 000-012-481 1 MJ-A10SPF0002-050, 5 m
Select one, for
system with locally
supplied monitor
*: See packing list at back of manual for details.

x
Option
Name Type Code No. Qty Remarks
MU-150C —
Monitor MU-100C —
1 set
Control Unit CH-252 — 1 set
Remote Controller CH-256-E — 1 set
Interface Unit IF-8000 — 1 set
Motion Sensor MS-100 — 1 set
Clinometer BS-704 — 1 set
Speaker SC-05WR 000-136-156 1
Signal Cable S06-9-5 006-556-270 1 Speaker extension cable,
5 m
MJ-A6SPF0012-050 000-134-424 1 6 pin-6 pin, 5 m
MJ-A6SPF0012-100 000-133-817 1 6 pin-6 pin, 10 m
MJ-A6SPF0011-050 000-132-244 1 6 pin-4 pin, 5 m
Cable Assy.
MJ-A6SPF0011-100 000-132-336 1 6 pin-4 pin, 10 m
OP06-15-1.5 NEW 006-559-140 1 With 1.5-m cable, for desktop
mounting
OP06-15-5 NEW 006-559-150 1 With 5 m cable, for desktop
mounting
OP02-83-1.5 001-413-600 1
With 1.5 m cable, for flush
mounting
Installation Kit for
Separate Type
Control Unit
OP02-83-5 001-413-610 1
With 5 m cable, for flush
mounting
Flush Mount Kit for
Display Unit/Control
Unit (integrated) OP06-16 006-556-300 1
For display unit and control
unit
Flush Mount Kit for
Display Unit
(separate) OP06-17 006-556-310 1 For display unit
Flush Mount Kit for
Control Unit OP06-18 006-556-320 1
Rectifier RU-1746B-2 000-030-439 1
06-013-2501 100-099-192 1 Steel, 1 m
06-013-2502 100-100-322 1 Steel, 1.8 m
06-013-2503 100-100-332 1 Steel, 3.5 m
06-022-2201 100-306-180 1 FRP, 1 m
Retraction Tank
06-022-2202 100-306-200 1 FRP, 1.8 m

1
1. MOUNTING
1.1 Display Unit, Control Unit
This searchlight sonar is available in two configurations: one with the FURUNO-supplied
display unit or one with no display unit and an interface unit (with which to connect a
monitor, locally supplied). For installation of the system which uses a locally supplied
monitor, see paragraph 1.1.3 on page 6 for monitor requirements and installation
information.
The control unit can be installed together with the display unit, or independently, using the
optional mounting kit. These units may be installed on a desktop or flush mounted in a
console.
1.1.1 General mounting considerations
• Keep the units out of direct sunlight.
• Select a location where the units can easily be operated while observing the fishing
ground or area surrounding the vessel.
• For maintenance and checking purposes, leave sufficient space at the sides and rear of
the units and leave slack in cable. (Refer to the outline drawing at the back of this manual
for recommended maintenance space.)
• A magnetic compass will be affected if the display unit (or control unit when it is installed
separately) is placed too close to the compass. Observe the following compass safe
distances to prevent deviation to the compass: Standard compass: 0.80 m, Steering
compass: 0.55 m.

2
1.1.2 Mounting the FURUNO-supplied display unit MU-100C
Desktop mounting
1. Fasten the mounting base to the mounting location with four tapping screws.
FRONT
Mounting Base
2. Do one of the following:
♦Mounting the display unit and control unit together:
1)Fasten the bracket at the rear of monitor and control units with four binding screws
(M4X10).
1
12
2
3
34
4
Bracket (rear view)
♦Mounting the display unit separately from the control unit:
1)Dismount the coupling plate at the rear of the display unit to separate the display unit
from the control unit.
2)Attach the bracket at the rear of the display unit with four binding screws (M4X10).
12
34
12
34
Bracket (rear view)
3. Coat threads of upset screws (M6X16, 2 pcs.), which are used to fasten the bracket to
the mounting base, with grease.

3
4. Fasten the bracket to the mounting base with two upset screws: Use the upper holes to
tilt the display unit 20°; lower holes to tilt it 9°.
Upset Screw
Bracket
Mounting Base
Use these holes to tilt
display unit 20
°
.
Use these holes to tilt
display unit 9
°
.
Mounting the control unit separate from the display unit
The optional control unit mounting kit is required. See the outline drawing at the back of this
manual for mounting details.
Control Unit Mounting Kit
Type: OP06-15-1.5 NEW (Code no. 006-559-140, with 1.5 m cable)
Type: OP06-15-5 NEW (Code no. 006-559-150, with 5 m cable)
Name Type Code No. Qty Remarks
MJ-A10SPF0002-015 000-142-878 For 1.5 m cableCable
MJ-A10SPF0002-050 000-131-411 1 For 5 m cable
Bracket 06-021-2112 100-281-880 1
Mounting Plate 06-021-2111 100-279-740 1
Tapping Screw 5X20 000-802-081 2
Cosmetic Cap DP-687 000-808-417 2
Hex. Screw M4X12 000-882-040 4

4
Flush mounting the display unit together with control unit
Flush Mount Kit for Display Unit/Control Unit
(Type OP06-16, Code no. 006-556-300)
Name Type Code No. Qty Remarks
Fixing Metal 06-021-1311 100-279-611 1
Tapping Screw 5X20 000-802-840 6
Hex. Bolt M4X12 000-882-040 4
1. Cut out hole (297(H) X 287(W)) in mounting location.
2. Fasten the fixing metal to the display and control units with four hex. bolts (M4X12).
3. Using four tapping screws (5X20), fasten the fixing metal attached at step 2 to the
mounting location.

5
Flush mounting the display unit
Flush Mount Kit for Display Unit
(Type OP06-17, Code no. 006-556-310)
Name Type Code No. Qty Remarks
Fixing Metal 06-021-1321 100-279-622 1
Tapping Screw 5X20 000-802-840 4
Hex. Bolt M4X12 000-882-040 4
1. Cut out hole (207(H) X 287(W)) in mounting location.
2. Fasten the fixing metal to the display unit with four hex. bolts (M4X12).
3. Using four tapping screws (5X20), fasten the fixing metal attached at step 2 to the
mounting location.
Flush mounting the control unit
Flush mount kits for control unit
Type OP02-83-1.5, Code no. 001-413-600 (1.5 m cable)
Type OP03-83-5, Code no. 001-413-610 (5 m cable)
Type OP06-18, Code no. 006-556-320 (no cable)
Name Type Code No. Qty Remarks
Fixing Metal 06-021-2101 100-279-731 1
Tapping Screw 5X20 000-802-840 4
Hex. Bolt M4X12 000-882-040 2
MJ-A10SPF0002-015 000-142-878 1.5 mCable Assy.
MJ-A10SPF0002-050 000-131-411 1 5 m
Choose
either one.
1. Cut out hole (87(H) X 287(W)) in mounting place.
2. Fasten the fixing metal to the control unit with two
hex. bolts (M4X12).
3. Using four tapping screws (5X20), fasten the
fixing metal assembled at step 2 to the mounting
location.
Hex. Bolts
Fixing Metal

6
1.1.3 System with locally supplied monitor
Monitor requirements
This system requires a standard VGA monitor, connected to the interface unit IF-8000.
Supply monitor and interconnection cable locally. A D-sub 15P connector is required for
connection to the DATA/VIDEO OUT port on the IF-8000. Use the three rows-type D-sub
connector; not the two rows-type.
YES NO
The monitor should satisfy the specifications shown below.
• VGA type
• ANALOG RGB 0.7 Vpp, positive polarity
• TLL level H, V, negative polarity
Mounting the control unit on a desktop
For the system which uses a locally supplied monitor, fix the control unit to the mounting
plate (supplied as accessories) as shown below. See the parts list FP06-01120 and outline
drawings at the back of this manual for details.
1. Fix the mounting plate to the mounting location with two tapping screws (5X20).
2. Fix the bracket to the control unit with two hex. screws (M4X12).
3. Insert screwdriver from the top of the mounting plate holes and then loosely fasten two
hex. screws (M4X12).
4. Attach the control unit to the mounting plate and then tightly fasten two hex. screws.
5. Attach two cosmetic caps to holes at the top of the mounting plate.
Cable entrance hole
Mounting
Plate Cable
Tapping Screws (5X20)
Fasten the screws to fix
the bracket.
Bracket
Bracket
Set to the hex.
screws tightened
at step 3.
Cable can be passed this direction.
6. Attach hard cover to protect the control unit.
How to remove the hard cover
Place your thumbs at the locations shown with
circles in the illustration at right, and then lift the
cover while pressing it with your thumbs.

7
1.2 Transceiver Unit
1.2.1 General mounting considerations
• The mounting location should be well ventilated and dry.
• The unit can be mounted on a bulkhead or a desktop. For bulkhead mounting, be sure
the bulkhead is strong enough to support the weight of the unit under the vibration
normally experienced onboard the vessel. If necessary, reinforce the mounting location.
• Secure maintenance space for ease of maintenance and service, referring to the outline
drawing for recommended maintenance space.
• The maximum length of the cable between the transceiver unit and the raise/lower drive
assy. is 30 m.
• The maximum length of the cable between the transceiver unit and the display unit (or
interface) is 10 m.
• A magnetic compass will be affected if the transceiver unit is placed too close to the
compass. Observe the following compass safe distances to prevent deviation to the
compass: Standard compass: 0.60 m, Steering compass: 0.35 m.
1.2.2 Mounting procedure
The transceiver unit may be mounted a desktop or a bulkhead. Fasten the unit to the
mounting location with four tapping screws (5 mm diameter, local supply).
16.5
431
4-
φ
6
455
±
1
250
±
1
475
294
For bulkhead mounting:
1. Screw in upper tapping screws, leaving 5 mm gap between bottom of screw head and
bulkhead as shown right.
2. Set the unit to the tapping screws and tighten screws.
3. Screw in lower tapping screws.

8
1.3 Hull Unit
1.3.1 General handling considerations
CAUTION
Do not turn on the equipment with the
transducer exposed to air as this may
damage the transducer.
The soundome may be painted with antifouling paint to keep marine life of the transducer.
Use “Marine Star 20,” manufactured by Chugoku Marine Co., Ltd., or equivalent. Paint only
the portion below the sticker. Painting metal parts will cause corrosion.
Sticker
Paint Area
1.3.2 Installation position considerations
Discussion and agreement are required with the dockyard and ship owner in deciding the
location for the hull unit. When deciding the location, take into account the following points:
•
Select an area where propeller noise, cruising noise, bubbles and interference from
turbulence are minimal. Generally, the point at 1/3 to 1/2 of the ship’s length from the bow
or near the keel is the best. On-the-keel installation is advantageous for minimizing oil
consumption in comparison with of-the-keel. If the hull unit cannot be installed on the keel,
the center of the retraction tank should be within 1 m of the keel to prevent a rolling effect.
1/2 1/3 Within 1 m
•
Select a place where interference from the transducers of other sounding equipment is
minimal. The hull unit should be at least 2.5 m away from the transducers of other
sounding equipment.
•
An obstacle in the fore direction not only causes a shadow zone but also aerated water,
resulting in poor sonar performance. Be sure to locate the transducer well away from any
obstacle in the fore direction.
Other manuals for CH-270
3
Table of contents
Other Furuno Sonar manuals

Furuno
Furuno CH-270 User manual

Furuno
Furuno FE-880 User manual

Furuno
Furuno DS-30 User manual

Furuno
Furuno CSH-8L User manual

Furuno
Furuno Black Box Searchlight Sonar CH-250BB User manual

Furuno
Furuno FSV-85-MARK-2 User manual

Furuno
Furuno FSV-35 User manual

Furuno
Furuno CSH-5LMARK-2 User manual

Furuno
Furuno FSV-84 User manual

Furuno
Furuno CH-37BB User manual

Furuno
Furuno CH-270 User manual

Furuno
Furuno CSH-21 User manual

Furuno
Furuno FSV-30 User manual

Furuno
Furuno CH-500 User manual

Furuno
Furuno CSH-5L/CSH-8L User manual

Furuno
Furuno FCV-1000 User manual

Furuno
Furuno FSV-24 User manual

Furuno
Furuno CH-37 User manual

Furuno
Furuno CSH-23 User manual

Furuno
Furuno DS-30 Manual