G-Tek LM Pro RF User manual

Pro
LM RF
Temp. & RH Datalogger
Model No.: 6xx...
G-Tek Corporation Pvt. Ltd.
3, mahavir estate, karelibaug
vadodara-390 018
tel.: +91-265-2461912
email: [email protected]
url: www.gtek-india.com
OPERATING
MANUAL
LM-H
Pro

G-Tek Corporation Pvt. LTD 1
Contents
CONTENTS
Contents..................................................................................................................................................1
List of Tables ...........................................................................................................................................3
1. Introduction ....................................................................................................................................4
1.1 Manual Layout ........................................................................................................................4
1.2 LM Pro RF Description.............................................................................................................4
1.3 Features ..................................................................................................................................5
1.4 Unpacking and inspection of LM Pro RF .................................................................................5
1.4.1 Status LEDs......................................................................................................................6
1.4.2 Display LCD......................................................................................................................6
Installation ......................................................................................................................................7
Operation........................................................................................................................................8
3.1 LM Pro RF Internal Schematics Diagram.................................................................................8
3.2 LM Pro RF OPERATION............................................................................................................8
Troubleshooting Guide ...................................................................................................................9
4.1 Operation Troubleshooting.....................................................................................................9
Standard Accessories ....................................................................................................................10
5.1 5 V DC @ 1.2 Amp ADAPTOR................................................................................................10
5.2 Ethernet Cable ......................................................................................................................10
Specification..................................................................................................................................11
Ordering Code...............................................................................................................................13

G-Tek Corporation Pvt. LTD 2
Contents
List of Figures
Figure 1 Front View of LM Pro RF ...........................................................................................................5
Figure 2 LCD Display................................................................................................................................6
Figure 3 Schematic diagram of Set up of LM Pro RF...............................................................................7
Figure 4 Internal Schematic diagram of LM Pro RF.................................................................................8
Figure 5 5 VDC 1.2 Amp Adaptor .........................................................................................................10
Figure 6 Ethernet Cable ........................................................................................................................10

G-Tek Corporation Pvt. LTD 3
List of Tables
LIST OF TABLES
Table 1 Manual Layout............................................................................................................................4
Table 2 Specification of LM Pro RF........................................................................................................11
Table 3 Sensor types and range............................................................................................................12
Table 4 LM Pro RF Order Code..............................................................................................................13

G-Tek Corporation Pvt. LTD 4
Introduction
1. INTRODUCTION
This manual is written to help the user to get familiar with the installation and operation of LM Pro RF.
It is designed for reliable and convenient recording of process parameters in production, Research and
Quality control applications. This device can sense the Temperature and Humidity, displaying them on
LCD display ae well as sending these data via RF signal to Moderator device for monitoring on
gtekNetTM.
1.1 MANUAL LAYOUT
This manual is divided into sections for quick and easy reference.
Table 1 Manual Layout
Section 1 Introduction
This gives outline of the manual, brief description about the LM Pro
RF, features available and how to unpack it.
Section 2 Installation
This section gives the details of the Electrical installation.
Section 3 Operation
This section describes the operation of LM Pro RF and the output
status on the LCD display.
Section 4
Troubleshooting Guide
This section describes about the most frequently asked questions
and their solutions about LM Pro RF.
Section 5 Accessories
This section shows the standard accessories for the LM Pro RF.
Section 6 Specification
It describes the detailed specification of the LM Pro RF.
Section 7 Ordering Code
It describes the details of order code and comparing it with the
code on the LM Pro RF, user can find out the installed options.
1.2 LM PRO RF DESCRIPTION
The LM Pro RF series of wireless data logger is a new RF based data logger measuring temperature
and % RH. These data loggers are very useful in monitoring data across large facilities where wiring is
difficult. Since no wiring is required, deployment is very quick and easy. Data are sent by each device
directly to the centralized moderator (repeater) device and from there to gtekNetTM software over
ethernet port. These data can be accessed from any network connected device using standard web
browser.
The data logger consists of RF radio transmitter and receiver operating at 869.88 MHz (SRD License
Free: EU Version) frequency. These data loggers form a star network with its moderator. The
moderator is connected to the client-server based gtekNetTM software through ethernet. A new data
logger when it is inthe range of the central node –moderator, gets easily connected to the gtekNetTM.
Each device transmits its data to the moderator and is captured in gtekNetTM. Any parameter of the
data logger when set / changed from gtekNetTM, first goes to the moderator and then to the device.
These data loggers have an internal memory of 32000 data sets. In the event of communication failure
between moderator and device or moderator and gtekNetTM, after reconnection, all the missed data
will be synchronized by gtekNetTM automatically. This ensures that no data is missed.

G-Tek Corporation Pvt. LTD 5
Introduction
1.3 FEATURES
Following features*are available for this LM Pro RF.
•RF based data logger
•Up to 100 m range (Line of Sight)
•No wiring required
•Quick to deploy
•Quick connect / disconnect port for pressure input
•Large individual display
•Long battery life > 1year at 15min Store interval
•Resolution of 0.1
•Up to 32000 data storage
•Optional USB power source.
* Features depends on the product ordered. Please refer to the order code (Model No) of your product for exact features
and capabilities.
1.4 UNPACKING AND INSPECTION OF LM PRO RF
LM Pro RF is dispatched in a recyclable, environment friendly package specially designed to give
adequate protection during transit. If the outer box shows sign of damage, it should be opened
immediately, and the LM Pro RF be examined. If there is evidence of damage, the instrument should
not be operated, and the local representative contacted for instructions. Ensure that all accessories
and documentation is removed from the box. If the LM Pro RF is for immediate use, you can start
installing it as per following instructions. Please preserve the original packing along with all internal
packing for future transport requirements. The figure 1 shows the front view of LM Pro RF device.
Figure 1 Front View of LM Pro RF

G-Tek Corporation Pvt. LTD 6
Introduction
1.4.1 Status LEDs
There are two status LEDs available on LM Pro RF device for the indication of device status. The
meaning of both the LEDs are described as below:
HBT
Heartbeat LED will be flickered at every 5 minutes for updating time of data,
after that it will be OFF till next interval comes.
STR
Storage LED will be flickered with Heartbeat LED, if Batch is ON at every 5
minutes. Otherwise, Storage LED will remain in OFF state if Batch is OFF.
1.4.2 Display LCD
The LCD display is 3 ½ digit display shows the Temperature and %RH value with its units, alarm
high/low indication and Recording indication as per the operation of the device. The LCD display parts
are shown in figure 2.
Figure 2 LCD Display
1) Measurement Program running (Batch running)
2) Alarm set limit value(s) exceeded.
3) Current reading
4) Units (%RH, °C)
5) Upper limit value exceeded
6) Lower limit value exceeded

G-Tek Corporation Pvt. LTD 7
Installation
INSTALLATION
For the installation, the LM Pro RF is powered ON by inserting battery in the device. Switch ON the
Moderator with 5 V DC adapter. Connect Moderator device with PC using ethernet cable for
communication. Please refer the schematic diagram given in figure 3 for setting up the connection.
The PC must have GtekNet application to configure the Moderator for observing the output data.
Figure 3 Schematic diagram of Set up of LM Pro RF
Moderator Device / Central Node
Communication via
RF signals
Communication via
RF signals
GtekNet Application in PC
LM Pro RF in Room1
LM Pro RF in Room2

G-Tek Corporation Pvt. LTD 8
Operation
OPERATION
3.1 LM PRO RF INTERNAL SCHEMATICS DIAGRAM
The internal schematic of LM Pro RF consists of various blocks as shown in figure 4.
Figure 4 Internal Schematic diagram of LM Pro RF
3.2 LM PRO RF OPERATION
•Once the Setup is done as per the schematic diagram, LM Pro RF show Room Temperature
and %RH on display continues Scrolling every 5 minutes.
•The HBT Led will flicker at 5 minutes time interval and display will be updated.
•The STR led will flicker with HBT Led at 5 minutes time interval, if Batch is running.
Otherwise STR led will remain in OFF state.
•When the Batch is running, recording indication is shown on LCD display as section3.4.1
LCD display.
•If alarm condition is created in any channel (Temperature or RH), Alarm high/low
indication will be shown on display as per section3.4.1 LCD display. Note that the display
will be blinked in Alarm condition.
•The Temperature and %RH data is also sent to the Moderator via RF signal and with the
help of Moderator the data will be observed on GtekNet Application.
•We can download the data in csv, pdf format using GtekNet application.

G-Tek Corporation Pvt. LTD 9
Troubleshooting Guide
TROUBLESHOOTING GUIDE
4.1 OPERATION TROUBLESHOOTING
Question
Possible Cause / Solution
Why is LCD display showing
constant Temp or %RH value
and not updated?
•Wait for 5 minutes, HRT LED will be flickered and Temp
and %RH will be updated.
•If HRT LED does not flicker, then contact to Gtek
Corporation.
How is Alarm condition shown
on LCD display?
•When Alarm occurs, it will be shown on LCD display by
UP/Down arrow and “ALARM” message will be on top of
the LCD display. The LCD display will be blinked on Alarm
condition.
If LCD display is OFF, then what
should be done?
•Check if battery is properly inserted in the device.

G-Tek Corporation Pvt. LTD 10
Standard Accessories
STANDARD ACCESSORIES
5.1 5VDC @1.2 AMP ADAPTOR
Figure 5 5 VDC 1.2 Amp Adaptor
Input Voltage: 100-240 V AC 0.35 Amp.
Operating Frequency: 50 to 60Hz.
Output voltage: 5V DC 1.2 Amp
5.2 ETHERNET CABLE
Figure 6 Ethernet Cable

G-Tek Corporation Pvt. LTD 11
Specification
SPECIFICATION
The Specifications of LM Pro RF are:
Table 2 Specification of LM Pro RF
Model No
LM Pro RF
Product Code:
Wireless RF Temperature / Humidity
Datalogger
Display and Operator Panels
Display Type
3½ digit LCD Display
Status Indicator
Unit Indication, High and Low Alarm Indication,
and storage on Indication
Analog Input Details
Sensor Types: (PCB mounted, Internal Sensors)
Temperature
Thermistor 10K /Solid state
%RH
Solid state
Sensor Type and Range and Accuracy
Refer to the Table 5
Batch Storage / Data Memory Details
Start / Stop
Remote Start –Stop through GtekNet
Store Interval
5 minutes to 18 Hours (multiple of 5 minutes)
Memory Size
32000 records totals; Rollover
Environmental
Temperature
(Operation) 5˚C to 45˚C
(Limiting) 0˚C to 50˚C
(Storage) -20˚C to 60˚C
Humidity
(Operation) 10 to 80 % RH Non-Condensing
(Storage) 5 to 90 % RH Non-Condensing
Altitude
<2000 meter
Power Requirement
Supply Voltage
Internal 2x1.5V 1500mAH battery size AA
Battery Life
>1 year at 15-minute store interval approx.
Power
1W Max with Maximum Configuration
Mains Operation
Through 5V Adapter; micro-USB connector
Communication
RF Transmission
869.88 MHz (SRD License Free: EU Version)
Power
Tx: 10dBm
Rx: -40dBm
Protocol
Proprietary
Range
100m (Line of Sight)
Network Topology
Star
RF Data Packet Standard
IEEE 802.15.4, open communication architecture
Antenna
Integrated on PCB Omnidirectional
Alarm Output
Alarm Set-point
High/Low individually settable for each channel
Buzzer
Audible on alarm condition
Overall Dimension
Dimension L x W x D (mm) approx.
140 x 75 x 30 Approx.

G-Tek Corporation Pvt. LTD 12
Specification
Table 3 Sensor types and range
Parameter
Sensor
Range
Accuracy
Temperature
Thermistor
-20 to +60 °C
± 0.5 °C
Temperature + %RH
Solid state
Temp.: -20 to +60 °C
± 0.5°C
%RH: 0-100 %
±2% RH between 20-80 %RH
±3% RH otherwise

G-Tek Corporation Pvt. LTD 13
Ordering Code
ORDERING CODE
LM Pro RF order code is as below: -
Table 4 LM Pro RF Order Code
Series
Input Type
Power Supply
Mounting Type
-
Software
Communication
Interface
6
LM Pro
RF
1
Temp
0
Battery
Operated
0
Handheld
4
GtekNet
Non-
Secure
6
Radio Frequency
(RF)
2
Temp +
RH +
1
Battery + Mains
operated
1
Flush
Mount
5
GtekNet
Secure
7
Bluetooth Low
Energy (BLE)
3
Temp +
RH +
Pressure
2
Wall
Mount
8
RF + BLE
Table of contents
Other G-Tek Data Logger manuals
Popular Data Logger manuals by other brands

Rand McNally
Rand McNally ELD 50 Operational description

Dostmann Electronic
Dostmann Electronic LOG10 Instructions for use

LogTag
LogTag USRIC-8 quick start guide

MadgeTech
MadgeTech RTDTemp2000 quick start guide

Fortinet
Fortinet FortiSIEM 500F Configuration guide

GREISINGER