GAI-Tronics 13310-311 Troubleshooting guide

Pub. 42004-502A
GAI-TRONICS 3030 KUTZTOWN RD. READING, PA 19605 USA
610-777-1374 800-492-1212 Fax: 610-796-5954
VISIT WWW.GAI-TRONICS.COM FOR PRODUCT LITERATURE AND MANUALS
GAI-TRONICS®
AHUBBELL COMPANY
Model 13310-3xx Series
Loudspeakers
Instruction and Service Manual
This manual covers the following loudspeaker models:
Model 13310-311, 16-ohm, 25 watts, UL Class I Division 1
Model 13310-312, 8-ohm, 25 watts, UL Class I Division 1
Model 13310-313, 70 V line, 25 watts, UL Class I Division 1

Pub. 42004-502A
_______________________________________________________________________________________________________________
Tel: 800-492-1212
GAI-Tronics 3030 Kutztown Rd. Reading PA 19605 USA
Document No. 42004-502A 09-29-15 [email protected]
www.gai-tronics.com Fax: 610-796-5954
Sheet 2 of 5
Warranty
Equipment. GAI-Tronics warrants for a period of one (1) year from the date of shipment, that any GAI-Tronics
equipment supplied hereunder shall be free of defects in material and workmanship, shall
comply with the then-current product specifications and product literature, and if applicable, shall be fit
for the purpose specified in the agreed-upon quotation or proposal document. If (a) Seller’s goods prove
to be defective in workmanship and/or material under normal and proper usage, or unfit for the purpose
specified and agreed upon, and (b) Buyer’s claim is made within the warranty period set forth above,
Buyer may return such goods to GAI-Tronics’ nearest depot repair facility, freight prepaid, at which time
they will be repaired or replaced, at Seller’s option, without charge to Buyer. Repair or replacement shall
be Buyer’s sole and exclusive remedy. The warranty period on any repaired or replacement equipment
shall be the greater of the ninety (90) day repair warranty or one (1) year from the date the original
equipment was shipped. In no event shall GAI-Tronics warranty obligations with respect to equipment
exceed 100% of the total cost of the equipment supplied hereunder. Buyer may also be entitled to the
manufacturer’s warranty on any third-party goods supplied by GAI-Tronics hereunder. The applicability
of any such third-party warranty will be determined by GAI-Tronics.
Services. Any services GAI-Tronics provides hereunder, whether directly or through subcontractors,
shall be performed in accordance with the standard of care with which such services are normally
provided in the industry. If the services fail to meet the applicable industry standard, GAI-Tronics will
re-perform such services at no cost to buyer to correct said deficiency to Company's satisfaction provided
any and all issues are identified prior to the demobilization of the Contractor’s personnel from the work
site. Re-performance of services shall be Buyer’s sole and exclusive remedy, and in no event shall GAI-Tronics
warranty obligations
.
Warranty Periods. Every claim by Buyer alleging a defect in the goods and/or services provided hereunder shall be
deemed waived unless such claim is made in writing within the applicable warranty periods as set forth above.
Provided, however, that if the defect complained of is latent and not discoverable within the above warranty periods,
every claim arising on account of such latent defect shall be deemed waived unless it is made in writing within a
reasonable time after such latent defect is or should have been discovered by Buyer.
Limitations / Exclusions. The warranties herein shall not apply to, and GAI-Tronics shall not be responsible for,
any damage to the goods or failure of the services supplied hereunder, to the extent caused by Buyer’s neglect,
failure to follow operational and maintenance procedures provided with the equipment, or the use of technicians not
specifically authorized by GAI-Tronics to maintain or service the equipment. THE WARRANTIES AND
REMEDIES CONTAINED HEREIN ARE IN LIEU OF AND EXCLUDE ALL OTHER WARRANTIES AND
REMEDIES, WHETHER EXPRESS OR IMPLIED BY OPERATION OF LAW OR OTHERWISE, INCLUDING
ANY WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE.
Return Policy
If the equipment requires service, contact your Regional Service Center for a return authorization number (RA#).
Equipment should be shipped prepaid to GAI-Tronics with a return authorization number and a purchase order
number. If the equipment is under warranty, repairs or a replacement will be made in accordance with the warranty
policy set forth above. Please include a written explanation of all defects to assist our technicians in their
troubleshooting efforts.
Call 800-492-1212 (inside the USA) or 610-777-1374 (outside the USA) for help identifying the Regional Service
Center closest to you.

__________________________________________________________________________________________________________________
Tel: 800-492-1212
GAI-Tronics 3030 Kutztown Rd. Reading PA 19605 USA
Document No. 42004-502A 09-29-15
www.gai-tronics.com Fax: 610-796-5954
Sheet 3 of 5
INSTRUCTION & SERVICE MANUAL
13310-3xx LOUDSPEAKERS
For Use In Hazardous Locations - Gas
The 13310-3xx series Loudspeakers are certified
by
UL as Audible-signal Appliances for Use in
HazardousLocations
1)
Introduction
The 13310-3xx series are UL certified loudspeakers which
produce a loud warning signal in a hazardous area. The
loudspeakers are approved for use in Gas applications in
Class I Division 1 & 2 as well as Class I Zone 0, 1 and 2.
2)
Warnings
CAUTION
TO REDUCE THE RISK OF IGNITION OF
HAZARDOUS ATMOSPHERES:
DISCONNECT FROM SUPPLY BEFORE OPENING.
KEEP TIGHTLY CLOSED WHEN IN OPERATION.
WARNING
FIT SEALING FITTING IN CONDUIT RUNS WITHIN 18
INCHES FROM ENCLOSURE.
EQUIPMENT MUST NOT BE INSTALLEDWITH THE
HORN FACING UPWARDS OF HORIZONTAL.
ATTENTION
POUR REDUIRE LE RISQUE D’INFLAMMATION
DES ATMOSPHÈRES DANGEREUSES:
COUPER L 'ALIMENTATION AVANT OUVERTURE.
CONSERVER FERMÉ PENDANT LE FONCIONNEMENT.
AVERTISSEMENT
CONDUITS DOIVENT ÊTRE SCELLÉS EN MOINS DE 18
POUCES.
ÉQUIPEMENT NE DOIT PAS ÊTRE INSTALLÉ AVEC
LE KLAXON TOURNÉE VERS LE HAUT DE
HORIZONTAL.
3)
Ratings and Markings
3.1 Class / Division Ratings for US and Canada
The 13310-3xx Loudspeakers comply with the following
standards for hazardous locations:
UL 1203
CSA C22.2 NO. 30-M1986
The 13310-3xx Loudspeakers also comply with the
following standards for signaling equipment:
UL 1480
CSA C22.2 NO. 205-12
3.2 Class / Division Ratings for US & Canada
Class I Div 1 ABCD T6 Ta −40°C to +70°C
Installation must be carried out in compliance with the
National Electric Code / Canadian Electric Code.
3.3 Class / Zone ratings US and Canada
Class I Zone 1 IIC T6 Ta −40ºC to +70°C
Installation must be carried out in compliance with the
National Electric Code / Canadian Electric Code.
3.4 Ambient Temperature Range
−40ºC to +70ºC
3.5 Enclosure Ratings
The product is rated for ingress protection as follows:
IP rating per EN60529: IP66
Type rating per UL50E / NEMA250: 4 / 4X / 3R / 13
3.6 Electrical Ratings
Model No. Input Power
(Watts) Max I/P
Volts
13310-313 70V Line 25 70
13310-312 8 Ohm 25 14.14
13310-311 16 Ohm 25 20
3.7 Frequency Range
All models: 400 Hz to 8000 Hz
4)
Installation
4.1 Safe Installation Requirements
The product must only be installed by suitably qualified
personnel in accordance with the latest issues of the
relevant standards.
The installation of the units must also be in accordance
with the NEC / CEC and any local regulations and should
only be carried out by a competent electrical engineer who
has the necessary training.

Pub. 42004-502A
__________________________________________________________________________________________________________________
Tel: 800-492-1212
GAI-Tronics 3030 Kutztown Rd. Reading PA 19605 USA
Document No. 42004-502A 09-29-15
www.gai-tronics.com Fax: 610-796-5954
Sheet 4 of 5
The Equipment must not be installed with the horn facing
upwards of horizontal.
To maintain the ingress protection rating and mode of
protection, the cable entries must be fitted with suitably
rated cable entry and/or blanking devices during installation.
If conduit is used for installation, seal conduit within 18
inches from the enclosure.
If entries are fitted with adaptors they must be suitably rated
for the application. Fitting of blanking elements into
adaptors is not permitted.
If a high IP (Ingress Protection) rating is required then a
suitable sealing washer or O-ring must be fitted under any
cable gland or blanking device with metric threads.
Only the explosionproof cover is to be used for access to
the enclosure for installation, service and maintenance.
Connections are to be made into the terminal blocks using
solid or stranded wire, sizes 0.5–2.5mm2/ AWG 20–12.
Wire insulation needs to be stripped 6–7mm. Wires may be
fitted securely with crimped ferrules. Terminal screws need
to be tightened down with a tightening torque of 0.4 Nm / 3.5
Lb-in.
Earthing connections should be made to the Internal Earth
terminal in the explosionproof chamber or the external
earth stud.
Check that the O-ring seal is in place before replacing the
explosionproof cover.
4.2 Mounting
Figure1. Fixing locations
13310-3xx Loudspeakers should only be installed by trained
competent personnel.
The Loudspeakers may be secured to any flat surface using
the three 7mm fixing holes. The enclosure provides IP66
protection and is suitable for indoor and outdoor use
providing it is positioned so that water cannot collect in the
horn, and the cable entry is sealed.
4.3 Installation Procedure
a. Secure the Loudspeaker to a flat surface via the three
7mm fixing holes in the mounting bracket.
b. Remove the explosionproof cover of the loudspeaker by
unscrewing it, taking care not to damage the threads in
the process. (Refer to Section 5.)
c. Fit an M20x1.5 suitably certified cable gland or ½” NPT
conduit into the corresponding entryin the enclosure and
connect the field wiring to the appropriate loudspeaker
terminals as shown in Section 6 / Figure 3 (70V Line In)
or Section 7 / Figure 4 (Low Impedance) of this manual.
The power supply terminals on the low impedance units
are duplicated so that units may be connected in parallel.
An end-of-line monitoring resistor may be fitted to either
type of unit. Additional entries which are not used must
always be fitted with suitably certified blanking elements.
d. Replace the explosionproof cover of the loudspeaker,
taking care not to damage the explosionproof threads and
checking that the O-ring seal is in place. Tighten the cover
fully.
4.4 Hornless Variants
The 13310-3xx Loudspeaker is also available as a variant
with no horn fitted in the factory. The Horn threaded nose
portion has a fitment thread of 1-3/8” – 18 UNF (to BS1580
or ANSI B1.1). The customer is responsible for sourcing
and correctly fitting a suitable horn that meets all of the
relevant safety requirements.
5)
Access to the Explosionproof Enclosure
In order to connect the electrical supply cables to the
loudspeaker, it is necessary to remove the explosionproof
cover to gain access to the explosionproof chamber. This
can be achieved by unscrewing the explosionproof cover,
taking extreme care not to damage the explosionproof
threads in the process.
Figure2.AccessingtheExplosionproofEnclosure
On completion of the cable wiring installation the explosionproof
threads should be inspected to ensure that they are clean and
that they have not been damaged during installation. Also check
that the O-ring seal is in placeon the threaddiameter in contact
with the flat face of the explosionproof cover. When replacing
the explosionproof cover ensure that it is tightened fully.
6)
70V Line In Wiring
Figure3.LineInTerminals
The cable connections are made into the terminal blocks on
the PCB assembly located in the explosionproof enclosure.
Internal Earth
Terminal
E
D
C
B
A
Blankin
g
elemen
t
External Earth
A
ssembl
y
(Appropriate
cable glands to
be customer
supplied) Flameproof
cover

Pub. 42004-502A
__________________________________________________________________________________________________________________
Tel: 800-492-1212
GAI-Tronics 3030 Kutztown Rd. Reading PA 19605 USA
Document No. 42004-502A 09-29-15 Fax: 610-796-5954
www.gai-tronics.com
Sheet 5 of 5
See Section 5 of this manual for access to the explosionproof
enclosure. The 70V Line loudspeakers are fitted with a five-
way terminal block. Terminal A is common and one of the
other terminals B, C, D or E should be selected depending
on what output level is required. (See table below.)
Terminals Watts
A - B 25W
A - C 12.5W
A - D 6W
A - E 2W
For 8-ohm and 16-ohm models a single conductor with a
cross sectional area of up to 2.5mm² / ~13 AWG can be
connected to each terminal. The 70V transformer model is
supplied with two (2) sets of terminals (in and out), a single
conductor with a cross sectional area of up to 2.5mm² / ~13
AWG can be connected to each terminal. If more than one
wire is fitted into a terminal, a ferrule should be used to
secure the wires. When connecting wires to the terminals,
great care should be taken to dress the wire so that when the
cover is inserted into the chamber the wires do not exert
excess pressure on the terminal blocks.
7)
Low Impedance Wiring
Figure4.LowImpedanceTerminals
The 8- ohm and 16-ohm low impedance models have
dual input terminals on the PCB assembly for input and
output wiring. A cable of up to 2.5mm² can be
connected to each terminal. If DC line monitoring is used, cut
the link on the board. (See Figure 4.)
8)
Earthing
The unit has both a primary internal and secondary
external earth fixing point.
Internal earth connections should be made to the internal
Earth terminal. See Figure 3 and Figure 4. It should be fitted
to the internal earth point using a ring crimp terminal to
secure the earth conductor.
In addition, external earth connections can be made to the
M5 earth stud (see Figure 2), using a ring crimp terminal to
secure the earth conductor to the earth stud. The external
earth crimp ring should be located between the two M5
plain washers provided and securely locked down with the
M5 spring washer and M5 nut.
The earth conductor should be at least equal in size and
rating to the incoming power conductors but at least a
minimum of 0.82mm2/ 18 AWG in size.
9)
End-of-Line DC Monitoring
On 13310-3xx Loudspeakers, DC line monitoring can be used
if required. Both the 70V Line units and the Low Impedance
units have blocking capacitors fitted. It should be noted that
each loudspeaker has a 1M ohm bleed resistor connected
across the blocking capacitor and this should be taken into
account when selecting the value of the end-of-line monitoring
resistance.
The end-of-line monitoring resistor can be connected across
the terminals on the end-of-line unit.
On 70V line units, the end-of-line resistor used must have
a minimum resistance value of 4k7 ohms and a minimum
wattage of 2.5 watts.
On low impedance units, the end-of-line resistor used must
have a minimum resistance value of 2k ohms and a minimum
wattage of 0.5 watts or a minimum resistance value of 500
ohms and a minimum wattage of 2 watts. On the low
impedance units, care must be taken with the polarity of the
monitoring voltage. If an end-of-line resistor is fitted to a unit,
the links on the printed circuit boards of all loudspeakers in the
line must be cut for the dc blocking capacitors to be in circuit in
order to dc monitor the line. (See Figure 4.)
10)
Maintenance, Repair and Overhaul
Maintenance, repair and overhaul of the equipment should
only be carried out by suitably qualified personnel in
accordance with the current relevant standards and
regulations.
Units must not be opened while an explosive atmosphere
is present.
If opening the unit during maintenance operations, a clean
environment must be maintained and any dust layer
removed prior to opening the unit.
The threaded flame path joints are not intended to be repaired.
Internal Earth
Terminal
DC Line
Monitoring Link
-
- + +

(Rev. 10/06)
Warranty
Equipment. GAI-Tronics warrants for a period of one (1) year from the date of shipment, that any
GAI-Tronics equipment supplied hereunder shall be free of defects in material and workmanship, shall
comply with the then-current product specifications and product literature, and if applicable, shall be fit
for the purpose specified in the agreed-upon quotation or proposal document. If (a) Seller’s goods prove
to be defective in workmanship and/or material under normal and proper usage, or unfit for the purpose
specified and agreed upon, and (b) Buyer’s claim is made within the warranty period set forth above,
Buyer may return such goods to GAI-Tronics’ nearest depot repair facility, freight prepaid, at which time
they will be repaired or replaced, at Seller’s option, without charge to Buyer. Repair or replacement shall
be Buyer’s sole and exclusive remedy. The warranty period on any repaired or replacement equipment
shall be the greater of the ninety (90) day repair warranty or one (1) year from the date the original
equipment was shipped. In no event shall GAI-Tronics warranty obligations with respect to equipment
exceed 100% of the total cost of the equipment supplied hereunder. Buyer may also be entitled to the
manufacturer’s warranty on any third-party goods supplied by GAI-Tronics hereunder. The applicability
of any such third-party warranty will be determined by GAI-Tronics.
Services. Any services GAI-Tronics provides hereunder, whether directly or through subcontractors,
shall be performed in accordance with the standard of care with which such services are normally
provided in the industry. If the services fail to meet the applicable industry standard, GAI-Tronics will
re-perform such services at no cost to buyer to correct said deficiency to Company's satisfaction provided
any and all issues are identified prior to the demobilization of the Contractor’s personnel from the work
site. Re-performance of services shall be Buyer’s sole and exclusive remedy, and in no event shall GAI-
Tronics warranty obligations with respect to services exceed 100% of the total cost of the services
provided hereunder.
Warranty Periods. Every claim by Buyer alleging a defect in the goods and/or services provided
hereunder shall be deemed waived unless such claim is made in writing within the applicable warranty
periods as set forth above. Provided, however, that if the defect complained of is latent and not
discoverable within the above warranty periods, every claim arising on account of such latent defect shall
be deemed waived unless it is made in writing within a reasonable time after such latent defect is or
should have been discovered by Buyer.
Limitations / Exclusions. The warranties herein shall not apply to, and GAI-Tronics shall not be
responsible for, any damage to the goods or failure of the services supplied hereunder, to the extent
caused by Buyer’s neglect, failure to follow operational and maintenance procedures provided with the
equipment, or the use of technicians not specifically authorized by GAI-Tronics to maintain or service the
equipment. THE WARRANTIES AND REMEDIES CONTAINED HEREIN ARE IN LIEU OF AND
EXCLUDE ALL OTHER WARRANTIES AND REMEDIES, WHETHER EXPRESS OR IMPLIED BY
OPERATION OF LAW OR OTHERWISE, INCLUDING ANY WARRANTIES OF
MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE.
Return Policy
If the equipment requires service, contact your Regional Service Center for a return authorization number
(RA#). Equipment should be shipped prepaid to GAI-Tronics with a return authorization number and a
purchase order number. If the equipment is under warranty, repairs or a replacement will be made in
accordance with the warranty policy set forth above. Please include a written explanation of all defects to
assist our technicians in their troubleshooting efforts.
Call 800-492-1212 (inside the USA) or 610-777-1374 (outside the USA) for help identifying the
Regional Service Center closest to you.
This manual suits for next models
2
Table of contents
Other GAI-Tronics Speakers manuals

GAI-Tronics
GAI-Tronics 13352 User manual

GAI-Tronics
GAI-Tronics 13382 WiFi Owner's manual

GAI-Tronics
GAI-Tronics 13354-001 User manual

GAI-Tronics
GAI-Tronics 670-001 User manual

GAI-Tronics
GAI-Tronics 13380-001 Troubleshooting guide

GAI-Tronics
GAI-Tronics RigCom 400-001 Operating manual

GAI-Tronics
GAI-Tronics 13350 User manual

GAI-Tronics
GAI-Tronics 13373 User manual

GAI-Tronics
GAI-Tronics 13360 User manual