Galactic RG57A2/BGEF User manual

CR242-RG57(A3,A2,A8)B
16117000A32437
20181112
Thank you very much for purchasing our air conditioner.
Please read this owner's manual carefully before using
your air conditioner. Make sure to save this manual for
future reference.
The design and specifications are subject to change without prior
notice for product improvement. Consult with the sales agency or
manufacturer for details.
ON /OFF
TE M P
SHORT
CUT
TIMER
ON
TIMER
OF F
MODE
FAN
SLEEP
TURBO CLEAN LED
FOLLOW
FRESH

1
CONTENTS
2
Model
Rated Voltage
8m
3.0V(Dry batteries R03/LR03×2)
Environment
Signal Receiving Range
RG57A2(B)/BGEF,RG57A8(B)/BGEF,RG57A3(B)/BGEF,
MODEL:RG57A8(B)/BGEF
O O
-5 C~60 C
1
3
4
5
6
13
Handling the remote controller ......................................................
Remote controller Specifications...................................................
Function buttons .................. .........................................................
Remote LCD screen indicators .....................................................
How to use the basic functions........................................................
How to use the advanced functions ...............................................
Remote Controller Specifications
Before you begin using your new air conditioner, make sure to familiarize yourself with its remote
control. The following is a brief introduction to the remote control itself. For instructions on how to
operate your air conditioner, refer to the How to Use Basic Functions section of this manual.
ECO
ON/OFF
Turns the unit on or off
MODE
Scrolls through operation
modes as follows:
AUTO
g
COOL
g
DRY
g
HEAT
g
FAN
FAN SPEED
Selects fan speeds in
the following order:
AUTO g LOW g
MED g HIGH
SLEEP
Saves energy during
sleeping hours
TURBO
FRESH
Enables unit to reach
preset temperature in
shortest possible time
TEMPp
Increases temperate in
O
1 C increments.
Max. temperature is
O
30 C .
TEMPq
Decreases temperate in
O
1 C increments.
Min. temperature is
O
17 C .
TIMER ON
Sets timer to turn unit
on (see How to Use
Basic Functions for
instructions)
TIMER OFF
Sets timer to turn unit
off (see How to Use
Basic Functions for
instructions)
SWING
Starts and stops louver
movement
LED
Turns indoor unit s LED display on and off.
,
FOLLOW ME
Temperature sensing
and room temperature
display button.
SELF CLEAN
Starts and stops
self clean feature.
ON/OFF
TEMP
TIMER
ON
TIMER
OFF
MODE
FAN
SLEEP
TURBO
FRESH
CLEAN LED
FOLLOW
Press this button, the
Ionizer/Plasma Dust
Collector(depending
on models) is energized
and will help to remove
pollen and impurities
from the air.
If you are sensitive to light when you go to
sleep, you can press the LED button to turn
off the LED display on the indoor unit. Press
the button again to turn it back on.
Function Buttons
NOTE:Please do not select
HEAT mode if the machine you
purchased is cooling only type.
Heat mode is not supported
by the cooling only appliance.
Used to enter the energy
efficient mode.

3 4
SHORT CUT
Sets and activates your
favourite pre-settings
ON/OFF
Turns the unit on or off
MODE
Scrolls through operation
modes as follows:
AUTO
g
COOL
g
DRY
g
HEAT
g
FAN
FAN SPEED
Selects fan speeds in
the following order:
AUTO g LOW g
MED g HIGH
SLEEP
Saves energy during
sleeping hours
TURBO
FRESH
Enables unit to reach
preset temperature in
shortest possible time
TEMP
p
Increases temperate in
O
1 C increments.
Max. temperature is
O
30 C .
TEMPq
Decreases temperate in
O
1 C increments.
Min. temperature is
O
17 C .
TIMER ON
Sets timer to turn unit
on (see How to Use
Basic Functions for
instructions)
TIMER OFF
Sets timer to turn unit
off (see How to Use
Basic Functions for
instructions)
SWING
Starts and stops louver
movement
LED
Turns indoor unit s LED display on and off.
,
FOLLOW ME
Temperature sensing
and room temperature
display button.
SELF CLEAN
Starts and stops
self clean feature.
NOT SURE WHAT A FUNCTION DOES?
Refer to the How to Use Basic Functions and
How to Use Advanced Functions sections
of this manual for a detailed description of
how to use your air conditioner.
SPECIAL NOTE
Button designs on your unit may differ
slightly from the example shown.
If the indoor unit does not have a particular
function, pressing that function s button
on the remote control will have no effect.
When there are wide differences between
Remote controller Illustration and
USER'S MANUAL on function description,
the description of USER'S MANUAL
shall prevail.
TIPS FOR USING REMOTE CONTROL
The remote control must be used within 8
meters of the unit.
The unit will beep when remote signal is
received.
Curtains, other materials and direct sunlight
can interfere with the infrared signal receiver.
Remove batteries if the remote will not be
used more than 2 months.
Inserting and Replacing Batteries
Put the two batteries(optional parts) in the
remote control before use.
1. Slide the back cover from the remote
control downward, exposing the battery
compartment.
2. Insert the batteries, paying attention to match
up the (+) and (-) ends of the batteries with
the symbols inside the battery compartment.
3. Slide the battery cover back into place.
BATTERY NOTES
For optimum product performance:
Do not mix old and new batteries, or
batteries of different types.
Do not leave batteries in the remote control
if you don t plan on using the device for
more than 2 months.
BATTERY DISPOSAL
Do not dispose of batteries as unsorted
municipal waste. Refer to local laws for
proper disposal of batteries.
,
,
ON/OFF
TEMP
SHORT
CUT
TIMER
ON
TIMER
OFF
MODE
FAN
SLEEP
TURBO
FRESH
CLEAN LED
FOLLOW
Press this button, the
Ionizer/Plasma Dust
Collector(depending
on models) is energized
and will help to remove
pollen and impurities
from the air.(This button
is not available for model
RG57A2(B)/BGEF.)
If you are sensitive to light when you go to
sleep, you can press the LED button to turn
off the LED display on the indoor unit. Press
the button again to turn it back on.
Handling The Remote Controller
,
,,
,
,
,
,
,
,
,,
,
NOTE:Please do not select
HEAT mode if the machine you
purchased is cooling only type.
Heat mode is not supported
by the cooling only appliance.
MODEL:
RG57A3(B)/BGEF
RG57A2(B)/BGEF
*

5 6
MODE display
Displays the current
mode, including:
AUTO
COOL
DRY
HEAT
FAN
Transmission Indicator
Lights up when remote sends
signal to indoor unit
ON/OFF display
Appears when the unit is turned on,
and disappears when it is turned off
TIMER ON display
Displays when TIMER
ON is set
TIMER OFF display
Displays when TIMER
OFF is set
SLEEP display
Battery display
FRESH display
SILENT display
ECO display
Displays when
SLEEP function
is activated
FOLLOW ME
display
Indicates that
the FOLLOW ME
function is on
FAN SPEED display
Displays selected FAN SPEED:
HIGH, MED,
or LOW
This display is blank when
set to AUTO speed or DRY mode.
Temperature/Timer display
Displays the set temperature by default, or timer setting
when using TIMER ON/OFF functions
o
Temperature range: 17-30 C
Timer setting range: 0-24 hours
This display is blank when operating in FAN mode.
1. Press the MODE button to select
COOL mode.
2. Set your desired temperature using
the Temp or Temp button.
3. Press the FAN button to select the
fan speed: AUTO, LOW, MED,or
HIGH.
4. Press the ON/OFF button to start the
unit.
In AUTO mode, the unit will automatically
select the COOL, FAN, HEAT or DRY mode
based on the set temperature.
1. Press the MODE button to select Auto mode.
2. Set your desired temperature using the
Temp or Temp button.
3. Press the ON/OFFbutton to start the unit.
,
NOTE: FAN SPEED can t be set in Auto mode.
SETTING TEMPERATURE
AUTO operation
The operating temperature range for units is
O
17-30 C. You can increase or decrease the
O
set temperature in 1 C increments.
COOL operation
1
3
2
1
3
2
4
Not available for this unit
Not available for
this unit
Displays when
ECO function is
activated(applicable
to RG57A8(B) only).
Low battery
detection
Remote LCD Screen Indicators How To Use The Basic Functions
ON/OFF
ON/OFF
TEMP
TEMP
SHORT
CUT
SHORT
CUT
TIMER
ON
TIMER
ON
TIMER
OFF
TIMER
OFF
MODE
MODE
FAN
FAN
SLEEP
SLEEP
TURBO
TURBO
FRESH
CLEAN
CLEAN
LED
LED
FOLLOW
FOLLOW
Information are displayed when the remote controller is powered up.
Note:
operation only the relative functional signs are shown on the display window.
All indicators shown in the figure are for the purpose of clear presentation. But during the actual

78
1. Press the MODE button to select DRY
mode.
2. Set your desired temperature using the
Temp or Temp button.
3. Press the ON/OFFbutton to start the unit.
,
NOTE: FAN SPEED can t be changed in
DRY mode.
1. Press the MODE button to select FAN
mode.
2. Press FAN button to select the fan
speed: AUTO, LOW, MED or HIGH.
3. Press the ON/OFFbutton to start the
unit.
,
NOTE: You can t set temperature in FAN
mode. As a result, your remote control s
LCD screen will not display temperature.
DRY operation(dehumidifying)
FAN operation
,
1. Press the MODE button to select
HEAT mode.
2. Set your desired temperature using
the Temp or Temp button.
3. Press the FAN button to select the
fan speed: AUTO, LOW, MED,or HIGH.
4. Press the ON/OFF button to start the
unit.
HEAT operation
NOTE: As outdoor temperature drops, the
performance of your unit s HEAT function
may be affected. In such instances, we
recommend using this air conditioner in
conjunction with other heating appliance.
,
1
1
2
3
3
2
1
3
2
4
How To Use The Basic Functions How To Use The Basic Functions
ON/OFF
TEMP
TIMER
ON
TIMER
OFF
MODE
FAN
SLEEP
TURBO
FRESH
CLEAN LED
FOLLOW
ON/OFF
TEMP
SHORT
CUT
TIMER
ON
TIMER
OFF
MODE
FAN
SLEEP
TURBO
FRESH
CLEAN LED
FOLLOW
ON/OFF
TEMP
SHORT
CUT
TIMER
ON
TIMER
OFF
MODE
FAN
SLEEP
TURBO
FRESH
CLEAN LED
FOLLOW

910
NOTE:
" 0.0h "
When setting the TIMER ON or
TIMER OFF functions, up to 10 hours,
the time will increase in 30 minute
increments with each press. After 10
hours and up to 24, it will increase in 1
hour increments. The timer will revert to
zero after 24 hours.
You can turn off either function by
setting its timer to .
2. Press the TIMER ON button repeatedly
to set the time when you want the unit to
turn on.
3. Wait 2 seconds, then the TIMER ON
function will be activated. The digital
display on your remote control will then
return to the temperature display.
2. Press the TIMER OFF button repeatedly
to set the time when you want the unit to
turn off.
3. Wait 2 seconds, then the TIMER OFF
function will be activated. The digital
display on your remote control will then
return to the temperature display.
Example
hours.
: Setting unit to turn on after 2.5
Example
hours.
: Setting unit to turn off after 5
2sec
ON/OFF
MODE
FAN
SHORT
CUT
TIMER ON
TIMER OF
F
TEMP
S
LEEP
1sec
x5
1
3
2
4
TIMER OFF function
The TIMER OFF function allows you to
set a period of time after which the unit
will automatically turn off, such as when
you wake up.
1.
The number indicates the
amount of time after the current time
that you want the unit to turn on.
For example, if you set TIMER ON for
2.5 hours, will appear on the
screen, and the unit will turn on after
2.5 hours.
Press the TIMER ON button, the TIMER
ON indicator and time display.
Note:
" 2.5h "
1.
The number indicates the
amount of time after the current time
that you want the unit to turn off.
For example, if you set TIMER OFF for
2 hours, will appear on the
screen, and the unit will turn off after
5 hours.
Press the TIMER OFF button, the TIMER
OFF indicator and time display.
Note:
" 5.0h "
2sec
x10
ON/OFF
MODE
FAN
SHORT
CUT
TIMER ON
TIMER OF
F
TEMP
S
LEEP
1sec
1
3
2
4
TIMER ON function
The TIMER ON function allows you to set
a period of time after which the unit will
automatically turn on, such as when you
come home from work.
Your air conditioning unit has two
timer-related functions:
TIMER ON- sets the amount of timer after
which the unit will automatically turn on.
TIMER OFF- sets the amount of time after
which the unit will automatically turn off.
TIMER ON TIMER ON
TIMER OFF TIMER OFF
Continue to press
TIMER ON or
TIMER OFF until
desired time is
reached.
Setting the TIMER function
ON/OFF
TEMP
SHORT
CUT
TIMER
ON
TIMER
OFF
MODE
FAN
SLEEP
TURBO
FRESH
CLEAN LED
FOLLOW
Timer on

11
Example: Setting the unit to turn on after 6 hours, operate for 2 hours, then turn off
(see the figure below)
Your remote display
Timer is set To turn ON
6 hours from current time
Timer is set to turn OFF
8 hours from current time
Current
time 1PM
2PM 3PM 4PM 5PM 6PM 7PM 8PM 9PM
Timer starts Unit turns Unit turns
ON OFF
6 hours later
8 hours later
Timer on
Timer off
12
Setting both TIMER ON and TIMER OFF at the same time
Keep in mind that the time periods you set for both functions refer to hours after the
current time. For example, say that the current time is 1:00 PM, and you want the unit
to turn on automatically at 7:00 PM. You want it to operate for 2 hours, then automa-
tically turn off at 9:00 PM.
Do the following:
ON/OFF
ON/OFF
MODE
MODE
SHORT
SHORT
CUT
CUT
TIMER ON
TIMER ON
TEMP
TEMP
3
sec
4
8
3
7
X12
X16
2
6
1
5
TIMER ON TIMER ON
TIMER OFF TIMER OFF

13
The FOLLOW ME function enables the
remote control to measure the temper-
ature at its current location. When using
AUTO, COOL, or HEAT functions,
measuring ambient temperature from
the remote control (instead of from the
indoor unit itself) will enable the air
conditioner to optimize the temperature
around you and ensure maximum comfort.
1. Press FOLLOW ME button to activate
function. The remote control will send
temperature signal to the indoor unit
every three minutes.
2. Press FOLLOW ME button again to
turn off this function.
The TURBO function makes the unit work
extra hard to reach your present temperature
in the shortest amount of time possible.
When you press the TURBO button in
COOL mode, the unit will blow cool air
with strongest wind setting to jump-start
the cooling process.
When you press the TURBO button in
HEAT mode, for units with Electric heat
elements, the Electric Heater will activate
and jump-start the heating process.
Airborne bacteria can grow in the moisture
condenses around heat exchanger in the unit.
With regular use, most of this moisture is
evaporated from the unit. By pressing the
CLEAN button, your unit will clean itself
automatically. After cleaning, the unit will turn
off automatically. Pressing the CLEAN button
mid-cycle will cancel the operation and turn
off the unit.
that
You can use CLEAN as often as you like.
Note: You can only activate this function
in COOL or DRY mode.
FOLLOW ME function
SHORTCUT function
(For RG57A3(B)/BGEF,RG57A2(B)/BGEF)
SWING function
SELF CLEAN function
TURBO function
SLEEP Function
The SLEEP function is used to decrease
energy use while you sleep (and don t need
the same temperature settings to stay
comfortable). This function can only be
activated via remote control.
Note: The SLEEP function is not available
in FAN or DRY mode.
,
Used to restore the current settings or resume
previous settings.
Push this button when remote controller is on, the
system will automatically revert back to the
previous settings including operating mode, setting
temperature, fan speed level and sleep feature
(if activated).
If pushing more than 2 seconds, the system will
automatically restore the current operation settings
including operating mode, setting temperature, fan
speed level and sleep feature(if activated ).
Swing Button
Swing Button
Used to stop or start horizontal louver movement
or set the desired up/down air flow direction. The
louver changes 6 degree in angle for each press.
If keep pushing more than 2 seconds, the louver
will swing up and down automatically.
Used to stop or start vertical louver movement
and set the desired left/right air flow direction.
The vertical louver changes 6 degree in angle
for each press. If keep pushing more than 2
seconds, the vertical louver auto swing feature
is activated.
How To Use The Advanced Functions How To Use The Advanced Functions
ON/OFF
ON/OFF
ON/OFF
TEMP
TEMP
TEMP
SHORT
CUT
SHORT
CUT
TIMER
ON
TIMER
ON
TIMER
ON
TIMER
OFF
TIMER
OFF
TIMER
OFF
MODE
MODE
MODE
FAN
FAN
FAN
SLEEP
SLEEP
SLEEP
TURBO
TURBO
TURBO
CLEAN
CLEAN
CLEAN
LED
LED
LED
FOLLOW
FOLLOW
FOLLOW
FRESH
FRESH
ECO function
(RG57A8(B)/BGEF model only)
Used to enter the energy efficient mode.
Under cooling mode, press this button,
the remote controller will adjust the
O
temperature automatically to 24 C, fan
speed of Auto to save energy(but only
O
if the set temperature is less than 24 C).
O
If the set temperature is above 24 C ,
press the ECO button, the fan speed
will change to Auto, the set temperature
will remain unchanged.
NOTE:
Pressing the ECO button, or modifying
the mode or adjusting the set temperature
O
to less than 24 C will stop ECO operation.
Under ECO operation, the set temper-
O
ature should be 24 C or more. it may
result in insufficient cooling. If you feel
uncomfortable, just press the ECO
button again to stop it.
ECO
MODEL:RG57A8(B)/BGEF
MODEL:RG57A2(B)/BGEF
MODEL:RG57A3(B)/BGEF

This manual suits for next models
5
Table of contents
Popular Remote Control manuals by other brands

Z-Wave
Z-Wave Z-URC XpressZetup Quick setup guide

CaryMart
CaryMart 0020750 manual

SMC Networks
SMC Networks EXW1-RLAPA8C Series instruction manual

Xantech
Xantech INJ94 installation instructions

Panasonic
Panasonic AJRC10G - REMOTE CONTROL UNIT Operation guide

Universal Electronics
Universal Electronics URC5110 user guide