Galanz Inverter
GALANZ INVERTER AIR CONDITIONER –COOLING AND HEATING
GALANZ 12000 BTU INVERTER 18000 BTU INVERTER
Model AUS-12H53R150P AUS-18H53R120C
Power 220~240V / 1 Phase / 50Hz 220~240V / 1 Phase / 50Hz
Heating Capacity 3800 W 5200 W
Cooling Capacity 3550 W 4800 W
SCOP 3,80 3,95
SEER 6,62 6,0
Standard input power
-Cool 1050 W 1600 W
-Heat pump 1050 W 1730 W
Max. Input consumption 2000 W 2400 W
Max. Current 10,5 A 10,65 A
Compressor type / brand Rotary / Panasonic Rotary / Hitachi
Energy Label Heating A A
Energy Label Cooling A++ A+
Operation temperature range -10~43 °C -7~43 °C
Ambient temperature range -15~48 °C -15~48 °C
Application area 40-115 m³ 80-170 m³
Waterproof class IP20(INDOOR) IP24(OUTDOOR)
Climate type T1
Indoor unit AUS-12H53R150P AUS-18H53R120C
Indoor air flow 500/450/380 m³/h 850/750/650/600 m³/h
Rated input power cooling/heating 20 W 50 W
Rated current (cooling/heating) 0,2 A 0,25 A
Moisture Removal 1.2 L/h 2.2 L/h
Sound power level 30-47 dB(A) 38-55 dB(A)
Net weight 11 kg 11 kg
Gross weight 12,5 kg 13
Unit dimension (WxHxD) 800x290x186 mm 860x293x203 mm
Packing (WxHxD) 855x355x255 mm 920x360x270 mm
Outdoor unit AUS-12H53R150P AUS-18H53R120C
Sound power level 32-59 dB(A) 47-64 dB(A)
Unit dimension (WxHxD) 745x552x328 mm 830x530x320 mm
Packing (WxHxD) 800x605x370 mm 910x620x380 mm
Net weight 30 kg 41 kg
Gross weight 33,5 kg 44,5 kg
Refrigerant type R410A R410A
Refrigerant charge 950 g 1200 g
Design pressure 4,1 MPa 4,1 MPa