Gamma Scale GMC-206 User manual

GMC-206/215/230 Digital Desktop
Weighing Scale
Operation Manual
Version 2.1
Gamma Scale
Tel: (905) 455-8333
Fax: (905) 455-0658
E-mail: [email protected]
Website: www.gammascale.com

Contents
1. Technical Parameters and Specifications
2. Main Functions
3. Construction
4. Operation Keys
5. Operation and Setting
5.1 Power-on
5.2 Zeroing
5.3 Tare
5.4 Weight unit conversion
5.5 Fixed value output
5.6 Backlight selection
5.7 Auto shut-off function
5.8 RS-232C output
6. Storage Battery (Option)
7. Use Guide
1. Technical Parameters and Specifications
1.1 Accuracy class: OIML III
1.2 Internal resolution ration: 270000
1.3 Display resolution ration: 30000
1.4 Zero point temperature drift ≤0.15 uV/°C
1.5 Sensitivity temperature drift ≤10 ppm /°C
1.6 Load cell excitation voltage: DC5V
1.7 Operation temperature: 0 - 40°C
1.8 Storage temperature: -25°C ~ 55°C
1.9 Relative humidity: ≤90%( no condensation)
1.10 Power supply: 110VAC, 6V/3.2Ah rechargeable storage battery option
1.11 Display 6 digit 1 inch LCD (with backlight)
1.12 Continual working time of storage battery
1.13 Platter size (mm): 250 x 300
1.14 Capacity: 6kg, 15kg, 30kg (15lbs/30lbs/60lbs)
1.15 Units: kg/lbs switchable
2. Main Functions
2.1 Auto zero when power on
2.2 Full range tare
2.3 Auto zero tracking
2.4 Filter selection
2.5 Fixed value output (warning)
- 1 -

2.6 Unit conversion
2.7 Low battery voltage indicating
2.8 Backlight selection (LCD display)
2.9 Auto shut-off
2.10 Key beep sound selecting
2.11 Simple rectifying
2.12 RS-232C output (option)
3. Construction
Cursor and Description:
Æ0ÅAppears when the loaded weight is within ±0.25e
AC Appears when AC power on
▪■■■ Appears when the battery is low voltage
Lb Weight unit selected is "pound"
Kg Weight unit selected is "kilogram"
Auto Off Appears when auto shut-off function is started
BL Appears when the backlight is started (only LCD display)
~ Appears when the scale is stable
G Appears when displaying Gross Weight
N Appears when displaying Net Weight and tare deduction is effective
Charge Light on when battery being recharged
4. Operation Keys
4.1 ON / UNITS / Å
a. Turn on PCB power
b. Weight unit conversion
c. Select digital place in calibration mode
4.2 OFF / ↑
a. Turn off PCB power
b. Make options to change successively in data setting
c. To change digit in 0, 1, 2, 3, 4, 5, 6, 7, 8, 9, 0 sequence
4.3 ZERO / BL
a. Zeroing within allowable range
b. Used when calibration
c. Switch on backlight (only LCD display)
4.4 TARE / ENTER
a. Tare deduction on platform
b. Used when calibration
- 2 -

5. Operation and Setting
5.1 Power-on
a. Adjust bearing support to make sure the scale is level.
b. While using AC power, insert power supply plug (or connect it with the power
adaptor). At the same time, if need to turn on DC power or charge the storage battery,
switch on the storage battery switch at "I" side.
c. Press [ON], display window displays a version number after giving out a beep
sound and at the same time its backlight (only LCD display) is switched on, then displays
its Max. capacity in about 1 second. After self checking, if zero position is normal, "0.00"
displays.
d. If the ▪■■■ indicating cursor is on, charge the storage battery in time.
5.2 Zeroing
When the weight is under 2%F • S, it displays "0" after pressing ZERO. The
accumulated zero range is 5%F • S.
Note: When the cursor "N" appears or indicating "NET" is on, zero operation doesn't
work.
5.3 Tare
When needs to tare, press [TARE], the indicator will display "0", and the cursor
indicating "N" will appear or indicating "NET" is on. While press [TARE] again, it
returns to the original tare and at the same time the cursor "N" changes to be "G" or the
indicating "NET" is off.
5.4 Weight unit conversion
When the function is allowed, press [ON], the weight unit will be changed once between
"kg" and "lb" and the relevant cursor will also appear.
5.5 Overload warning
The value is Max. Capacity plus 9e ("e" refers to division value) according to
regulations when the products leave our company. For example, if the scale is 6kg Max.
Capacity with 1g division, its warning value is 6.009kg. When the loaded weight is not
less than the setup value, the scale gives out beep sound and at the same time displays
“FULL”.
5.6 Backlight selection
Under non-calibrating state, if the backlight is not switched on, keep on pressing
[ZERO] about 3 seconds and then release the key, now the backlight is switched on and
the cursor pointing to "BL" appears at the same time. When the backlight has been
switched on, press [ZERO] about 3 seconds and then release this key, the backlight will
- 3 -

be switched off and the relevant cursor will disappear.
Note: No matter whether its backlight function has been switched on or not, the
backlight will automatically switch on about 1 second once powered on.
5.7 Auto Shut-off
If this function enabled, the scale will automatically shut off in 4 minutes after
operation stop, at this time the indicating cursor "Auto Off" will appear. The result of
auto shut-off is the same with pressing [OFF].
Prompt: The meaning for operation stop is that all the operation keys are not operated
when the scale is remained at zero position.
5.8 RS-232C output
The scale transmits RS-232C signal in continuous mode by MCS-51 way 1, the data
to be sent is ASCII code, every group has 16 frames including I frame of start character
(02), 2 frames of state mark, I frame of empty case character, 6 frames of displaying data
and 6 frames of tare data. Every frame consists of 10 digits. The first is start bit, "0". The
tenth is stop bit, "1". The other eight are data bits (from low to high), the patterns is as
follows:
Start Bit D0 D1 D2 D3 D4 D5 D6 D7 Stop Bit
Note: The Baud rate for its data output is usually set at t200 when the scale leaves
the company, and you may amend the Baud rate in calibrating state according to your
need.
6. Storage Battery Maintenance
6.1 When the low voltage indicate light appears, it means the battery voltage is too low
for the scale to work normally. At this time, charge the battery. With AC power, charge
can be processed while operating. If do not charge the low voltage battery in time, and
continue to operate it, the scale will be forced to shut off in several minutes.
6.2 If it automatically shut off as soon as DC power turns on, it means its battery voltage
is too low, at this time, charge the battery at once.
6.3 If the working time of storage battery is rather short than fully charged, it is
recommended to change the storage battery. Open the battery box cover, pulling up the
positive and negative metal pieces and removing the old storage battery. While opening
the cover, be careful to make sure the battery will not drop. Be sure of correct connection
of the storage battery's electrode.
6.4 If the scale is not used for a long time, be sure that the storage battery is in power-off
status.
- 4 -

7. Use Guide
7.1 The scale should be levelly placed. Though the scale has good protection, it is
suggested to use in clean and stable condition.
7.2 While weighing, place the load in the center of the platform as far as possible.
7.3 Never use high corrosive solvent to clean it.
7.4 Don't weigh (tare included) exceeds its Max. Capacity plus 9e ("e" refers to division),
when the weight exceed the value, the indicator displays FULL.
7.5 Never over-load it. Don't place weighing goods on the scale platform for a long
period of time. Never bump the platform with weighing goods; otherwise the load cell
shall be damaged.
7.6 Be sure that AC power plug is properly grounded.
7.7 Don't disassemble it without authorization.
7.8 If the display don't change while loading, or don't respond after pressing [OFF] with
AC power switch off. At this time, turn off the battery switch and after a moment turn on
the switch again, and then press [ON] to start again. That assures the reset of CPU after
power off.
7.9 Turn off power supply and pull off its power plug at once if it is out of order.
Unprofessional staff can't fix it without authorization; Contact our sales agent in local
area for help.
7.10 If recalibrate is needed, do it after the scale warms up on for 30 minutes.
NOTICE
GMC-2XX Serial Digital Desktop Weighing Scale and the manual may change without
further notice. For service, please contact your location provider.