GAPOSA XQ40 User manual

SAFETY
CAREFULLY FOLLOW THESE INSTRUCTIONS.
IT IS VERY IMPORTANT FOR THE SAFETY OF
PERSONS. SAVE THESE INSTRUCTIONS.
IMPORTANT:
•Checktheshutter/awninginmotionandkeep
personsfarfromitwhileinaction.
•Frequentlycheckifanylossofbalance,signsof
wearordamagedwiresareshown.
•Donotuseifanyrepairingormaintenanceis
needed.
•Incaseofinstallationinawningskeepa
distanceofatleast0,4mfromit(completely
open)andwhateverxediteminthenearby.
•Thedeviceisnotintendedtobeusedbypeople
(includingchildren)whosephysical,sensory
ormentalcapabilitiesarereduced,orlacking
experienceorknowledge,unlesstheyhavebeen
grantedthroughtheintermediaryofaperson
responsiblefortheirsafety,supervisionor
instructionconcerningtheuseofthedevice.
•Childrenshouldbesupervisedtoensurethey
donotplaywiththedeviceand/orwithx
controldevices.
•Thecontroldevicesinstalledinaxedmanner
mustbepositionedinview.

1/2
To complete installation, the motor must be provided with a couple of
adaptors (corresponding with the tube) and a fixing bracket. For a list of the
available accessories, refer to the catalogue.
WARNING: incorrect installation can cause serious injuries. Follow
the installation instructions. Before you remove all unnecessary
cables and turn off any equipment not required for this operation.
1Fix the adaptors to the motor distinguishing the limits ring from
the drive pulley .
A
B
2Insert the motor into the tube until its end stops against the
limits ring.
E
F
INSTALLATION

2/2
3
The fixing bracket must be fixed inside the box or on the awning
frame so that the roller tube is perfectly horizontal and at a
height not less than 1,8m.
4
[FOR XQ50] Place the motor square pin on the bracket and
the cap at the opposite end of the tube on the fixing plate.
WARNING: Never hit on the head of the motor (D) when you
insert it into the tube.
F
90°
min1,8m
C
D
NOTES
•For the XQ50, with torque up to 15Nm, the minimum tube diameter
is 50x1,5mm; for motors with higher torques, the minimum tube
diameter is 60x1,5mm.
•For the XQ60, the minimum tube diameter is 63x1,5mm.
WARNING:
•The screws used to fix the last slat on the tube may be too long
and reach the tubular part of the motor. Use appropriate screws or
fixing clips.
•Motor moving parts installed under 2,5m from the ground must be
protected.
•A wrong motor installation can damage persons or objects.
INSTALLATION

P
4x0.75 mm2
ELECTRICAL CONNECTION
Check that the mains voltage available on the system is as shown
on the label. The motor mains connection should be executed according
to the diagram on the next page, by qualified technicians able to operate in
compliance with the rules.
ATTENTION: The power supply must contemplate a switching device
with an opening distance between contacts of at least 3mm.
The motors connecting cables to the network can only be replaced with
cables of the same type provided by the motor manufacturer.
•Do not connect more than one tubular motor to a single switch.
•Do not set the shutter/awning into motion while you are cleaning or
servicing the device and disconnect the supply.
•The switch controlling the motor must be installed in full view, not higher
than 1,5m and it must be kept far from moving parts.
230 V~ / 50 Hz
Powersupply
Neutral Blue
Ground Yellow/Green
Direction of rotation 1 Brown
Direction of rotation 2 Black
Neutral
Ground
Phase
PPush button

1/2
NOTE: For the auto limits setting it is required that the roller
shutter features a botton bar capable to stops the screen at the
up end position.
OPTION 1
Use the setting switch
device ACPRE/ACPRET
ACPRE ACPRET
STOP STOP
Pressing and holding Up and
Down buttons together till
the motor jogs
STOP STOP
PROGRAMMING
B
A

2/2
PROGRAMMING
OPTION 2
Use any standard push button
1
Press the Up button and
release it as soon as the
motor starts running for 3
times
2
Press the Down button and
release it as soon as the
motor starts running for 2
times
3
Press and hold the Down
button for the 3rd time till the
motor makes a jog. The motor
is now in programming mode
Note: you can understand that the motor is in programming
mode by a brief start & stop of the motor while running.
x3
x2

AUTOMATIC LIMIT SETTING
1
Press and hold the UP button for more than 2 seconds then
release.
The motor runs upward to the TOP limit, stops itself (because the
bottom bar beats against the cassette) and sets the TOP limit.
After few seconds it starts running automatically downwards to
self-set the BOTTOM limit. When the roller shutter is completely
closed the motor stops setting the BOTTOM limit
2”
2”
2
To double check make a full
TOP/BOTTOM cycle of the
roller shutter

1/2
MANUAL LIMIT SETTING
The setting switch device ACPRE/ACPRET is required (the UP and
DOWN buttons can be pushed simultaneously).
1
Push the UP and DOWN but-
tons simultaneously till the
motor makes a jog
STOP STOP
UP LIMIT POSITION
2a
OPTION 1
Keep pushing the UP button
till the motor goes against
the top stop setting the UP
limit
2b
OPTION 2
Move the motor to the UP limit position then push the UP and
DOWN buttons simultaneously till the motor makes a jog. The UP
end limit position is now set.
DOWN LIMIT POSITION

DEACTIVATING OBSTACLE
SENSITIVITY
1Press UP button
2As soon as the motor runs upward
press DOWN button
3As soon as the motor runs
downward press UP button
4As soon as the motor runs upward
press DOWN button
5As soon as the motor runs
downward press UP button
6
When the motor runs upward
press and hold DOWN button until
you get 1 jog as confirmation of
deactivation.
ACTIVATING OBSTACLE SENSITIVITY

GAPOSA srl - via Ete, 90
63900 Fermo - Italy
ACTIVATING OBSTACLE
SENSITIVITY
1Press UP button
2As soon as the motor runs upward
press DOWN button
3As soon as the motor runs
downward press UP button
4As soon as the motor runs upward
press DOWN button
5As soon as the motor runs
downward press UP button
6
When the motor runs upward
press and hold DOWN button until
you get 2 jog as confirmation of
activation. x2
Other manuals for XQ40
3
This manual suits for next models
2
Table of contents