CAP indicates the elevator maximum capacity. Toviewthecurrent value press
AL 1 is the load value totrigger Alarm Relay1.Toviewthecurrent value press
AL 2 is the load value totrigger Alarm Relay2.Toviewthecurrent value press
An internal sounder beeps when an overload alarm is triggered or when the keypad is pressed.
Tochangethesetting, press and use To toggle beteween On and OFF.
Opon for turning the display on or o when the li is moving, the door close signal
acvates. Tochangethesetting, press and use To toggle between On and OFF.
The filter value determines the update rateanddampingfactor.Theavailable settings are:
0=0.4sec,1=0.8sec,2=1.2sec,3=1.6sec.
Defines the time from the control signal input is activated and the car load is stored.
Default =2, the available settings are: 0 = 0sec, 1 = 0.5sec, .....7 = 3.5sec.
Defines the value by which the load in the lift has todrop to resettheinstrument,
once the alarm has been triggered.
AL 3 is similar toAlarms1&2butallowsnegative values tobeentered. When editing the
mostsignificantdigit,instead of rolling over from 9 to 0 it included the minus sign option.
dLy
FIL
bEEP
5rES
AL 1
AL 2
AL 3
Opon to turn the systems reset funcon on or o. Leave OFF during system set up and zero and
load calibraon. Select ON aer calibraon and before entering the li into service.
To changethesetting, press and use To toggle beteween On and OFF.
Select the required Analog output . Refer to page 4 for available outputs
CAL
SYST
EWS-102 CONTROL UNIT - MULTI ANALOG SYSTEM SETUP
Select the firstmenuitem.
When a value is displayed, use to select the digit to
edit selected digit ashes and use to step through the
values for that digit.
Press to save a change. The system will revert to the
operaonal display aer approx. 10 seconds. Alternavely,
return to the operaonal display by pressing twice
Eding Values
Tobeginthesystem
setup, press the and
buttons together.
Enter the system setup menu. Unl a sensor is connected, the EWS will display Err6
prevenng access to the system setup and calibraon
menus
To calib rate the EWS 102, a link must be ed to the
control signal input terminals
Calibraon and set up can be carried out on any oor,
but the EWS 102 must be re-zeroed at the lowest oor
to nalise the Analog output calibraon.
Notes
Use the buon to step through the menu items.
Press to view the menu item